3745-18-07 Adams county emission limits.

(A) No owner or operator of any coal-fired steam generating unit, unless otherwise specified below, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 3.6 pounds of sulfur dioxide per MM Btu actual heat input.

(B) The "Dayton Power and Light Company, J. M. Stuart Electric Generating Station" (OEPA premise number 0701000007) or any subsequent owner or operator of the "Dayton Power and Light Company, J. M. Stuart Electric Generating Station," Aberdeen, Ohio shall not cause or permit the emission of sulfur dioxide from the following sources to exceed the amounts indicated:

(1) Auxiliary boiler and diesel unit numbers 1 through 4 (OEPA source numbers B005 through B009); a maximum of 0.5 pounds of sulfur dioxide per MM Btu actual heat input from each unit.

(2) Boiler numbers 1 through 4 (OEPA source numbers B001 through B004); a maximum of 3.16 pounds of sulfur dioxide per MM Btu actual heat input from each boiler.

(C) The "Dayton Power and Light Company, Killen Electric Generating Station" (OEPA premise number 0701000060) or any subsequent owner or operator of the "Dayton Power and Light Company, Killen Electric Generating Station," Monroe Township, Ohio shall not cause or permit the emission of sulfur dioxide from boiler unit number 2 (OEPA source number B001) to exceed a maximum of 1.2 pounds of sulfur dioxide per MM Btu actual heat input.

Effective: 02/17/2011
R.C. 119.032 review dates: 11/30/2010 and 11/30/2015
Promulgated Under: 119.03
Statutory Authority: 3704.03(E)
Rule Amplifies: 3704.03(A) , 3704.03(E)
Prior Effective Dates: 12/28/79, 5/11/87