3501.1 General. This chapter lists the standards that are referenced in various sections of the building code. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title. The application of the referenced standards shall be as specified in Section 102.5.
3501.2 Referenced codes. When indicated in this code, the following codes refer to provisions in the listed chapters of the administrative code:
|
Referenced Code |
Ohio Administrative Code Chapters |
|
Building Code Energy Code Fire Code Mechanical CodeOhio Boiler and Pressure Vessel Rules Ohio Elevator Code Residential Code of Ohio for One, Two and Three Family Dwellings |
4101:1-1 to 4101:1-35 4101:1-13 1301:7-1 to 1301:7-7 4101:2-1 to 4101:2-15 4101:4-1 to 4101:4-10 4101:5-1 to 4101:5-3 4101:8-1 to 4101:8-44 |
|
Plumbing Code |
4101:3-1 to 4101:3-13 |
|
|
|
3501.3Building Code Referenced Standards.
Aluminum Association
1525 Wilson Boulevard, Suite 600
Arlington, VA 22209
|
AA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
ADM1-10 |
Aluminum Design Manual: Part 1-A Specification for |
|
Aluminum Structures, Allowable Stress Design; and Part 1- |
|
|
B-Aluminum Structures, Load and Resistance Factor |
|
|
Design |
|
|
ASM 35-00 |
Aluminum Sheet Metal Work in Building Construction |
|
(Fourth Edition) |
American Architectural Manufacturers Association
1827 Waldon Office
Square, Suite 550
Schaumburg, IL 60173
|
AAMA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
1402-09 |
Standard Specifications for Aluminum Siding, |
|
Soffit and Fascia |
|
|
AAMA/WDMA/CSA |
|
|
101/I.S.2/A440-08 |
North American Fenestration |
|
Standard/Specifications for Windows, Doors and |
|
|
Skylights |
American Concrete Institute
38800 Country Club Dive
Farmington Hills, MI 48331
|
ACI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
216.1-07 |
Standard Method for Determining Fire Resistance of |
|
Concrete and Masonry Construction Assemblies |
|
|
318-08 |
Building Code Requirements for Structural Concrete |
|
530-08 |
Building Code Requirements for Masonry Structures |
|
530.1-08 |
Specifications for Masonry Structures |
American Forest & Paper Association
1111 19th St, NW Suite 800
Washington, DC 20036
|
AF&PA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
WCD No. 4-03 |
Wood Construction Data-Plank and Beam |
|
Framing for Residential |
|
|
NDS-05 |
National Design Specification (NDS) for |
|
Wood Construction with 2005 Supplement |
|
|
AF&PA-93 |
Span Tables for Joists and Rafters |
|
ANSI/AF&PA PWF-07 |
Permanent Wood Foundation Design |
|
Specification |
|
|
ANSI/AF&PA SDPWS-08 |
Special Design Provisions for Wind and |
|
Seismic |
American Institute of Steel Construction
One East Wacker Drive, Suite 3100
Chicago, IL 60601-2001
|
AISC |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
341-05 |
Seismic Provisions for Structural Steel Buildings, including |
|
Supplement No. 1 dated 2005 |
|
|
360-05 |
Specification for Structural Steel Buildings |
American Iron and Steel Institute
1140 Connecticut Avenue
Suite 705 Washington, DC 20036
|
AISI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
S100-07 |
North American Specification for the Design of Cold- |
|
formed Steel Structural Members |
|
|
S200-08 |
North American Standard for Cold-formed Steel |
|
Framing-General |
|
|
S210-08 |
North American Standard for Cold-formed Steel |
|
Framing-Floor and Roof System Design |
|
|
S211-08 |
North American Standard for Cold-formed Steel |
|
Framing-Wall Stud |
|
|
S212-08 |
North American Standard for Cold-formed Steel |
|
Framing-Header Design |
|
|
S213-08 |
North American Standard for Cold-formed Steel |
|
Framing-Lateral Design |
|
|
S214-08 |
North American Standard for Cold-formed Steel |
|
Framing-Truss Design, with Supplement 2, dated 2008 |
American Institute of Timber Construction
Suite 140
7012 S. Revere Parkway
Englewood, CO 80112
|
AITC |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
AITC Technical |
|
|
Note 7-96 |
Calculation of Fire Resistance of Glued Laminated |
|
Timbers |
|
|
AITC 104-03 |
Typical Construction Details |
|
AITC 110-01 |
Standard Appearance Grades for Structural Glued |
|
Laminated |
|
|
AITC 113-01 |
Standard for Dimensions of Structural Glued |
|
Laminated Timber |
|
|
AITC 117-04 |
Standard Specifications for Structural Glued |
|
Laminated Timber of Softwood Species |
|
|
AITC 119-96 |
Standard Specifications for Structural Glued |
|
Laminated Timber of Hardwood |
|
|
AITC200-09 |
Manufacturing Quality Control Systems Manual for |
|
Structural Glued Laminated Timber |
|
|
ANSI/AITCA 190.1-07 |
Structural Glued Laminated Timber |
Automotive Lift Institute
P.O. Box 85
Courtland, NY 13045
|
ALI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
ALI ALCTV-2007 |
Standard for Automobile Lifts-Safety |
|
Requirements for Construction, Testing and |
|
|
Validation (ANSI) |
American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
|
ANSI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
A13.1-07 |
Scheme for the Identification of Piping Systems |
|
A108.1A-09 |
Installation of Ceramic Tile in the Wet-set Method, with |
|
Portland Cement |
|
|
A108.1B-09 |
Installation of Ceramic Tile, quarry Tile on a Cured |
|
Portland Cement Mortar Setting Bed with Dry-set orLatex- |
|
|
A108.4-09 |
Installation of Ceramic Tile with Organic Adhesives or |
|
Water-cleanable Tile-setting Epoxy Adhesive |
|
|
A108.5-09 |
Installation of Ceramic Tile with Dry-set Portland Cement |
|
Mortar or Latex-portland Cement Mortar |
|
|
A108.6-09 |
Installation of Ceramic Tile with Chemical-resistant,Water |
|
Cleanable Tile-setting and -grouting Epoxy |
|
|
A108.8-09 |
Installation of Ceramic Tile with Chemical-resistant Furan |
|
Resin Mortar and Grout |
|
|
A108.9-09 |
Installation of Ceramic Tile with Modified Epoxy |
|
Emulsion Mortar/Grout |
|
|
A108.10-09 |
Installation of Grout in Tilework |
|
A118.1-10.1 |
American National Standard Specifications for Dry-set |
|
Portland Cement |
|
|
A118.3-10.1 |
American National Standard Specifications for Chemical- |
|
resistant, Water-cleanable Tile-setting and -grouting Epoxy |
|
|
and Water Cleanable Tile-setting Epoxy |
|
|
A118.4-10.1 |
American National Standard Specifications for Latex- |
|
portland Cement |
|
|
A118.5-10.1 |
American National Standard Specifications for Chemical |
|
Resistant Furan Mortar and Grouts for Tile |
|
|
A118.8-10.1 |
American National Standard Specifications for Modified |
|
Epoxy Emulsion Mortar/Grout |
|
|
A136.1-10.1 |
American National Standard Specifications for Organic |
|
Adhesives for Installation of Ceramic |
|
|
137.1-08 |
American National Standard Specifications for Ceramic |
|
A208.1-09 |
Particleboard |
|
Z 97.1-09 |
Safety Glazing Materials Used in Buildings-Safety |
|
Performance Specifications and Methods of Test |
APA - Engineered Wood Association
7011 South 19th
Tacoma, WA 98466
|
APA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
APA PDS-08 |
Panel Design Specification |
|
APA PDS |
|
|
Supplement 1-90 |
Design and Fabrication of Plywood Curved Panels (revised |
|
1995) |
|
|
APA PDS |
|
|
Supplement 2-92 |
Design and Fabrication of Plywood-lumber Beams (revised |
|
1998 |
|
|
APA PDS |
|
|
Supplement 3-96 |
Design and Fabrication of Plywood Stressed-skin Panels |
|
(revised 1996 |
|
|
APA PDS |
|
|
Supplement 4-93 |
Design and Fabrication of Plywood Sandwich Panels |
|
(revised 1993) |
|
|
APA PDS |
|
|
Supplement 5-95 |
Design and Fabrication of All-plywood Beams (revised |
|
1995 |
|
|
EWS R540-07 |
Builders Tips: Proper Storage and Handling of Glulam |
|
Beams |
|
|
EWS S475-07 |
Glued Laminated Beam Design Tables |
|
EWS S560-10 |
Field Notching and Drilling of Glued Laminated Timber |
|
Beams |
|
|
EWS T300-07 |
Glulam Connection |
|
EWS X440-08 |
Product Guide- Glulam |
|
EWS X450-01 |
Glulam in Residential Construction-Western Edition |
The Association of Pool & Spa Professionals
2111 Eisenhower Avenue
Alexandria, VA 22314
|
APSP Standard reference number |
Title |
|
ANSI/APSP 7-06 |
Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs and Catch Basins |
American Society of Agricultural and Biological Engineers
2950 Niles Road
St. Joseph, MI 49085
|
ASABE |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
EP 484.2 -98 |
Diaphragm Design of Metal-clad, Post-frame Rectangular |
|
Buildings |
|
|
EP 486.1 -99 |
Shallow-post Foundation Design |
|
EP 559 -03 |
Design Requirements and Bending Properties for |
|
Mechanically Laminated Columns |
American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400
|
ASCE/SEI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
3-91 |
Structural Design of Composite Slabs |
|
5-08 |
Building Code Requirements for Masonry |
|
6-08 |
Specification for Masonry Structures |
|
7-05 |
Minimum Design Loads for Buildings and Other Structures |
|
including Supplements No. 1 and 2, excluding Chapter 14 and |
|
|
Appendix 11A |
|
|
8-02 |
Standard Specification for the Design of Cold-formed Stainless |
|
Steel Structural Members |
|
|
19-10 |
Structural Applications of Steel Cables for Buildings |
|
24-05 |
Flood Resistant Design and Construction |
|
29-05 |
Standard Calculation Methods for Structural Fire Protection |
|
32-01 |
Design and Construction of Frost Protected Shallow Foundations |
American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329-2305
|
ASHRAE |
|
|
Standard |
|
|
Reference |
|
|
Number |
Title |
|
ASHRAE 90.1-2007 |
Energy Standard for Buildings Except Low-Rise Buildings |
American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
|
ASME |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
A17.1/CSA B44-2010 |
Safety Code for Elevators and Escalators |
|
A18.1-2008 |
Safety Standard for Platform Lifts and Stairway |
|
Chairlifts |
|
|
A90.1-2009 |
Safety Standard for Belt Manlifts |
|
B16.18-2001 |
|
|
(Reaffirmed 2005) |
Cast Copper Alloy Solder Joint Pressure Fittings |
|
B16.22-2001 |
|
|
(Reaffirmed 2005) |
Wrought Copper and Copper Alloy Solder Joint |
|
Pressure Fittings |
|
|
B20.1-2009 |
Safety Standard for Conveyors and Related |
|
Equipment |
|
|
B31.3-2008 |
Process Piping |
ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
|
ASTM |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
A 36/A 36M-08 |
Specification for Carbon Structural Steel |
|
A 153/A 153M-09 |
Specification for Zinc Coating (Hot-dip) on Iron |
|
and Steel Hardware |
|
|
A 240/A 240M-10a |
Standard Specification for Chromium and |
|
Chromium-nickel Stainless Steel Plate, |
|
|
Sheet and Strip for Pressure Vessels and for |
|
|
General Applications |
|
|
A 252-10 |
Specification for Welded and Seamless Steel Pipe |
|
Piles |
|
|
A 283/A 283M-03(2007) |
Specification for Low and Intermediate Tensile |
|
Strength Carbon Steel Plates |
|
|
A 307-07b |
Specification for Carbon Steel Bolts and Studs, |
|
60,000 psi Tensile Strength |
|
|
A 416/A 416M-10 |
Specification for Steel Strand, Uncoated Seven-wire |
|
for Prestressed Concrete |
|
|
A 463/A 463M-09a |
Standard Specification for Steel Sheet, Aluminum- |
|
coated, by the Hot-dip Process |
|
|
A 572/A 572M-07 |
Specification for High-strength Low-alloy |
|
Columbium-vanadium Structural Steel |
|
|
A 588/A 588M-10 |
Specification for High-strength Low-alloy |
|
Structural Steel with 50 ksi (345 MPa) |
|
|
Minimum Yield Point to 4 inches (100 mm) Thick |
|
|
A 615/A 615M-09b |
Specification for Deformed and Plain Billet-steel |
|
Bars for Concrete Reinforcement |
|
|
A 653/A 653M-09a |
Specification for Steel Sheet, Zinc-coated |
|
Galvanized or Zinc-iron Alloy-coated |
|
|
Galvannealed by the Hot-dip Process |
|
|
A 690/A 690M-07 |
Standard Specification for High-strength Low-alloy |
|
Nickel, Copper, Phosphorus Steel H-piles and |
|
|
Sheet Piling with Atmospheric Corrosion |
|
|
Resistance for Use in Marine Environments |
|
|
A 706/A 706M-09b |
Specification for Low-alloy Steel Deformed and |
|
Plain Bars for |
|
|
Concrete Reinforcement |
|
|
A 722/A 722M-07 |
Specification for Uncoated High-strength Steel Bar |
|
for Prestressing |
|
|
A 755/A 755M-03(2008) |
Specification for Steel Sheet, Metallic-coated by the |
|
Hot-dip Process and Prepainted by the |
|
|
Coil-coating Process for Exterior Exposed Building |
|
|
Products |
|
|
A 792/A 792M-09a |
Specification for Steel Sheet, 55% Aluminum-zinc |
|
Alloy-coated by the Hot-dip Process |
|
|
A 875/A 875M-09a |
Standard Specification for Steel Sheet Zinc-5 |
|
percent, Aluminum Alloy-coated by the Hot-dip |
|
|
Process |
|
|
A 913/A 913M-07 |
Specification for High-strength Low-alloy Steel |
|
Shapes of Structural Quality, Produced by |
|
|
Quenching and Self-tempering Process (QST) |
|
|
A 924/A 924M-10 |
Standard Specification for General Requirements |
|
for Steel Sheet, Metallic-coated by the Hot-dip |
|
|
Process |
|
|
A 992/A 992M-06a |
Standard Specification for Structural Shapes |
|
B 42-10 |
Specification for Seamless Copper Pipe, Standard |
|
B 43-09 |
Specification for Seamless Red Brass Pipe, |
|
Standard Sizes |
|
|
B 68-02 |
Specification for Seamless Copper Tube, Bright |
|
Annealed (Metric |
|
|
B 88-09 |
Specification for Seamless Copper Water Tube |
|
B 101-07 |
Specification for Lead-coated Copper Sheet and |
|
Strip for Building Construction |
|
|
B 209-07 |
Specification for Aluminum and Aluminum Alloy |
|
Steel and Plate |
|
|
B 251-10 |
Specification for General Requirements for |
|
Wrought Seamless Copper and Copper-alloy Tube |
|
|
B 280-08 |
Specification for Seamless Copper Tube for Air |
|
Conditioning and Refrigeration Field Service |
|
|
B 370-09 |
Specification for Cold-rolled Copper Sheet and |
|
Strip for Building Construction |
|
|
B 695-04(2009) |
Standard Specification for Coatings of Zinc |
|
Mechanically Deposited on Iron and Steel |
|
|
C 5-10 |
Specification for Quicklime for Structural |
|
C 22/C 22M-00 (2005)e01 |
Specification for Gypsum |
|
C 27-98 (2008) |
Specification for Standard Classification of Fireclay |
|
and High-alumina Refractory Brick |
|
|
C 28/C 28M-10 |
Specification for Gypsum |
|
C 31/C 31M-10 |
Practice for Making and Curing Concrete Test |
|
Specimens in the Field |
|
|
C 33-08 |
Specification for Concrete Aggregates |
|
C 34-10 |
Specification for Structural Clay Load-bearing Wall Tile |
|
C 35-01(2009) |
Specification for Inorganic Aggregates for Use in |
|
Gypsum Plaster |
|
|
C 36/C 36M-03 |
Specification for Gypsum Wallboard |
|
C 37/C 37M-01 |
Specification for Gypsum Lath |
|
C 55-09 |
Specification for Concrete Building Brick |
|
C 56-10 |
Specification for Structural ClayNonloadBearing Tile |
|
C 59/C 59M-00 (2006) |
Specification for Gypsum Casting and Molding |
|
Plaster |
|
|
C 61/C 61M-00 (2006) |
Specification for Gypsum Keene's |
|
C 62-10 |
Specification for Building Brick (Solid Masonry |
|
Units Made from Clay or Shale |
|
|
C 67-09 |
Test Methods of Sampling and Testing Brick and |
|
Structural Clay |
|
|
C 73-05 |
Specification for Calcium Silicate Face Brick |
|
(Sand-lime Brick) |
|
|
C 79-04a |
Specification for Treated Core and Nontreated Core |
|
Gypsum Sheathing Board |
|
|
C 90-09 |
Specification for Loadbearing Concrete Masonry |
|
Units |
|
|
C 91-05 |
Specification for Masonry Cement |
|
C 94/C 94M-10 |
Specification for Ready-mixed |
|
C 126-10 |
Specification for Ceramic Glazed Structural Clay |
|
Facing Tile, Facing Brick and Solid Masonry Units |
|
|
C 140-10 |
Test Method Sampling and Testing Concrete |
|
Masonry Units and Related Units |
|
|
C 150-09 |
Specification for Portland Cement |
|
C 172-10 |
Practice for Sampling Freshly Mixed |
|
C 199-84 (2005) |
Test Method for Pier Test for Refractory Mortars |
|
C 206-03 (2009) |
Specification for Finishing Hydrated Lime |
|
C 208-08a |
Specification for Cellulosic Fiber Insulating Board |
|
C 212-10 |
Specification for Structural Clay Facing Tile |
|
C 216-10 |
Specification for Facing Brick (Solid Masonry |
|
Units Made from Clay or Shale |
|
|
C 270-10 |
Specification for Mortar for Unit Masonry |
|
C 315-07 |
Specification for Clay Flue Liners and Chimney Pots |
|
C 317/C 317M-00 (2005) |
Specification for Gypsum Concrete |
|
C 330-09 |
Specification for Lightweight Aggregates for |
|
Structural Concrete |
|
|
C 331-05 |
Specification for Lightweight Aggregates for |
|
Concrete Masonry Units |
|
|
C 406-10 |
Specification for Roofing Slate |
|
C 442/C 442M-04 |
Specification for Gypsum Backing Board and |
|
Coreboard and Gypsum Shaftliner Board |
|
|
C 472-99 (2009) |
Specification for Standard Test Methods for |
|
Physical Testing of Gypsum, Gypsum Plasters and |
|
|
Gypsum Concrete |
|
|
C 473-10 |
Test Method for Physical Testing of Gypsum Panel |
|
Products |
|
|
C 474-05 |
Test Methods for Joint Treatment Materials for |
|
Gypsum Board Construction |
|
|
C 475-02 (2007) |
Specification for Joint Compound and Joint Tape |
|
for Finishing Gypsum Wallboard |
|
|
C 503-10 |
Specification for Marble Dimension Stone (Exterior |
|
C 514-04 (2009)e1 |
Specification for Nails for the Application of |
|
Gypsum |
|
|
C 516-08 |
Specifications for Vermiculite Loose Fill Thermal |
|
C 547-07e1 |
Specification for Mineral Fiber Pipe Insulation |
|
C 549-06 |
Specification forPerliteLoose Fill |
|
C 552-07 |
Standard Specification for Cellular Glass Thermal |
|
Insulation |
|
|
C 557-03(2009)e01 |
Specification for Adhesives for Fastening Gypsum |
|
Wallboard to Wood Framing |
|
|
C 568-10 |
Specification for Limestone Dimension Stone |
|
C 578-10 |
Standard Specification for Rigid, Cellular |
|
Polystyrene Thermal Insulation |
|
|
C 587-04 (2009) |
Specification for Gypsum Veneer Plaster |
|
C 588/C 588M-01 |
Specification for Gypsum Base for Veneer Plasters |
|
C 595-10 |
Specification for Blended Hydraulic Cements |
|
C 615-10 |
Specification for Granite Dimension |
|
C 616-10 |
Specification for Quartz Dimension Stone |
|
C 629-10 |
Specification for Slate Dimension |
|
C 630/C 630M-03 |
Specification for Water-resistant Gypsum Backing |
|
Board |
|
|
C 631-09 |
Specification for Bonding Compounds for Interior |
|
Gypsum Plastering |
|
|
C 635/C 635M-07 |
Specification for the Manufacture, Performance and |
|
Testing of Metal Suspension Systems for Acoustical |
|
|
Tile and Lay-in Panel |
|
|
C 636/C 636M-08 |
Practice for Installation of Metal Ceiling |
|
Suspension Systems for Acoustical Tile and Lay-in |
|
|
Panels |
|
|
C 645-09a |
Specification for Nonstructural Steel Framing |
|
Members |
|
|
C 652-10 |
Specification for Hollow Brick (Hollow Masonry |
|
Units Made from Clay or Shale |
|
|
C 728-05 (2010) |
Standard Specification forPerliteThermal Insulation |
|
Board |
|
|
C 744-10 |
Specification for Prefaced Concrete and Calcium |
|
Silicate Masonry |
|
|
C 754-09a |
Specification for Installation of Steel Framing |
|
Members to Receive Screw-attached Gypsum Panel |
|
|
Products |
|
|
C 836/C 836M-10 |
Specification for High-solids Content, Cold Liquid- |
|
applied Elastomeric Waterproofing Membrane for |
|
|
Use with Separate Wearing Course |
|
|
C 840-08 |
Specification for Application and Finishing of |
|
Gypsum Board |
|
|
C 841-03 (2008)e1 |
Specification for Installation of Interior Lathing and |
|
Furring |
|
|
C 842-05 |
Specification for Application of Interior Gypsum |
|
Plaster |
|
|
C 843-99 (2006) |
Specification for Application of Gypsum Veneer |
|
Plaster |
|
|
C 844-10 |
Specification for Application of Gypsum Base to |
|
Receive Gypsum Veneer Plaster |
|
|
C 847-10a |
Specification for Metal Lath |
|
C 887-05 (2010) |
Specification for Packaged, Dry Combined |
|
Materials for Surface Bonding Mortar |
|
|
C 897-05 (2009) |
Specification for Aggregate for Job-mixed Portland |
|
Cement-based Plaster |
|
|
C 920-10 |
Standard for Specification forElastomericJoint |
|
Sealants |
|
|
C 926-06 |
Specification for Application of Portland Cement- |
|
based Plaster |
|
|
C 931/C 931M-04 |
Specification for Exterior Gypsum Soffit Board |
|
C 932-06 |
Specification for Surface-applied Bonding |
|
Compounds Agents for Exterior Plastering |
|
|
C 933-09 |
Specification for Welded Wire Lath |
|
C 946-10 |
Specification for Practice for Construction of Dry- |
|
stacked, Surface-bonded Walls |
|
|
C 954-10 |
Specification for Steel Drill Screws for the |
|
Application of Gypsum Panel Products or Metal |
|
|
Plaster Bases to Steel Studs from 0.033 inch (0.84 |
|
|
mm) to 0.112 inch (2.84 mm) in Thickness |
|
|
C 955-09a |
Standard Specification for Load-bearing Transverse |
|
and Axial Steel Studs, Runners Tracks, and Bracing |
|
|
or Bridging, for Screw Application of Gypsum |
|
|
Panel Products and Metal Plaster Bases |
|
|
C 956-04 (2010) |
Specification for Installation of Cast-in-place |
|
Reinforced Gypsum |
|
|
C 957-10 |
Specification for High-solids Content, Cold Liquid- |
|
applied Elastomeric Waterproofing Membrane with |
|
|
Integral Wearing Surface |
|
|
C 960-04 |
Specification forPredecoratedGypsum Board |
|
C 1002-07 |
Specification for Steel Self-piercing Tapping |
|
Screws for the Application of Gypsum Panel |
|
|
Products or Metal Plaster Bases to Wood Studs or |
|
|
Steel Studs |
|
|
C 1007-08a |
Specification for Installation of Load Bearing |
|
(Transverse and Axial) Steel Studs and Related |
|
|
Accessories |
|
|
C 1019-09 |
Test Method of Sampling and Testing Grout |
|
C 1029-10 |
Specification for Spray-applied Rigid Cellular |
|
Polyurethane Thermal Insulation |
|
|
C 1032-06 |
Specification for Woven Wire Plaster Base |
|
C 1047-10a |
Specification for Accessories for Gypsum |
|
Wallboard and Gypsum Veneer |
|
|
C 1063-08 |
Specification for Installation of Lathing and Furring |
|
to Receive Interior and Exterior Portland Cement- |
|
|
based Plaster |
|
|
C 1088-10 |
Specification for Thin Veneer Brick Units Made |
|
from Clay or Shale |
|
|
C 1167-03 (2009) |
Specification for Clay Roof Tiles |
|
C 1177/C 1177M-08 |
Specification for Glass Mat Gypsum Substrate for |
|
Use as Sheathing |
|
|
C 1178/C 1178M-08 |
Specification for Coated Glass Mat Water-resistant |
|
Gypsum Backing Panel |
|
|
C 1186-08 |
Specification for Flat-Fiber Cement Sheets |
|
C 1261-10 |
Specification for Firebox Brick for Residential |
|
Fireplaces |
|
|
C 1278/C 1278M-07a |
Specification for Fiber-reinforced Gypsum Panels |
|
C 1280-09 |
Specification for Application of Gypsum Sheathing |
|
C 1283-07a |
Practice for Installing Clay Flue Lining. |
|
C 1288-99 (2010) |
Standard Specification for Discrete Nonasbestos |
|
Fiber-cement Interior Substrate Sheets |
|
|
C 1289-10 |
Standard Specification for Faced Rigid Cellular |
|
Polyisocyanurate Thermal Insulation Board |
|
|
C 1314-10 |
Test Method for Compressive Strength of Masonry |
|
Prisms |
|
|
C 1325-08b |
Standard Specification for Nonasbestos Fiber-mat |
|
Reinforced Cement Interior Substrate Sheets |
|
|
C 1328-05 |
Specification for Plastic (Stucco Cement |
|
C 1386-07 |
Specification for Precast Autoclaved Aerated |
|
Concrete (AAC) Wall Construction |
|
|
C 1395/C 1395M-06a |
Specification for Gypsum Ceiling Board |
|
C 1396M-09a |
Specification for Gypsum Board |
|
C 1405-10 |
Standard Specification for Glazed Brick (Single |
|
Fired, Solid Brick Units |
|
|
C 1492-03 (2009) |
Standard Specification for Concrete Roof |
|
C 1629/C 1629M-06 |
Standard Classification for Abuse-resistant |
|
Nondecorated Interior Gypsum Panel Products and |
|
|
Fiber-reinforced Cement Panels |
|
|
C 1658/C 1658M-06 |
Standard Specification for Glass Mat Gypsum |
|
Panels |
|
|
D 25-99 (2005) |
Specification for Round Timber Piles |
|
D 41-05 (2010) |
Specification for Asphalt Primer Used in Roofing, |
|
Dampproofing and Waterproofing |
|
|
D 43-00 (2006) |
Specification for Coal Tar Primer Used in Roofing, |
|
Dampproofing and Waterproofing |
|
|
D 56-05 |
Test Method for Flash Point By Tag Closed Tester |
|
D 86-10a |
Test Method for Distillation of Petroleum Products |
|
at Atmospheric Pressure |
|
|
D 93-10 |
Test Method for Flash Point ByPensky- |
|
MartensClosed Cup Tester |
|
|
D 225-07 |
Specification for Asphalt Shingles (Organic Felt) |
|
Surfaced with Mineral Granules |
|
|
D 226/D 226M-09 |
Specification for Asphalt-saturated Organic Felt |
|
Used in Roofing and Waterproofing |
|
|
D 227-03 |
Specification for Coal-tar-saturated Organic Felt |
|
Used in Roofing and Waterproofing |
|
|
D 312-00 (2006) |
Specification for Asphalt Used in |
|
D 422-63 (2007) |
Test Method for Particle-size Analysis of Soils |
|
D 448-08 |
Standard Classification for Sizes of Aggregate for |
|
Road and Bridge |
|
|
D 450-07 |
Specification for Coal-tar Pitch Used in Roofing, |
|
Dampproofing and Waterproofing |
|
|
D 635-10 |
Test Method for Rate of Burning and/or Extent and |
|
Time of Burning of Self-supporting Plastics in a |
|
|
Horizontal Position |
|
|
D 1143/D 1143M-07e1 |
Test Method for Piles Under Static Axial |
|
Compressive Load |
|
|
D 1227-95 (2007) |
Specification for Emulsified Asphalt Used as a |
|
Protective Coating for Roofing |
|
|
D 1557-09 |
Test Method for Laboratory Compaction |
|
Characteristics of Soil Using Modified Effort |
|
|
[56,000 ft-lb/ft3 (2,700 KN m/m3)] |
|
|
D 1586-08a |
Specification for Penetration Test and Split-barrel |
|
Sampling of Soils |
|
|
D 1761-06 |
Test Method for Mechanical Fasteners in Wood |
|
D 1863-05 |
Specification for Mineral Aggregate Used on Built- |
|
up Roofs |
|
|
D 1929-96 (2001)e01 |
Test Method for Determining Ignition Properties of |
|
Plastics |
|
|
D 1970-09 |
Specification for Self-adhering Polymer Modified |
|
Bituminous Sheet Materials Used as Steep Roof |
|
|
Underlayment for Ice Dam Protection |
|
|
D 2166-06 |
Test Method for Unconfined Compressive Strength |
|
of Cohesive Soil |
|
|
D 2178-04 |
Specification for Asphalt Glass Felt Used in |
|
Roofing and Waterproofing |
|
|
D 2216-10 |
Test Method for Laboratory Determination of Water |
|
(Moisture) Content of Soil and Rock by Mass |
|
|
D 2487-10 |
Practice for Classification of Soils for Engineering |
|
Purposes (Unified Soil Classification System) |
|
|
D 2626-04 |
Specification for Asphalt Saturated and Coated |
|
Organic Felt Base Sheet Used in Roofing |
|
|
D 2822-05 |
Specification for Asphalt Roof Cement |
|
D 2823-05 |
Specification for Asphalt Roof Coatings |
|
D 2843-10 |
Test for Density of Smoke from the Burning or |
|
Decomposition of Plastics |
|
|
D 2850-03a (2007) |
Test Method for Unconsolidated, Undrained |
|
Triaxial Compression Test on Cohesive Soils |
|
|
D 2898-10 |
Test Methods for Accelerated Weathering of Fire- |
|
retardant-treated Wood for Fire Testing |
|
|
D 3019-08 |
Specification for Lap Cement Used with Asphalt |
|
Roll Roofing, Nonfibered, Asbestos Fibered and |
|
|
NonasbestosFibered |
|
|
D 3161-09 |
Test Method for a Wind Resistance of Asphalt |
|
Shingles (Fan Induced Method) |
|
|
D 3200-74 (2005) |
Standard Specification and Test Method for |
|
Establishing Recommended Design Stresses for |
|
|
Round Timber Construction Poles |
|
|
D 3201-08ae1 |
Test Method for Hygroscopic Properties of Fire- |
|
retardant-treated Wood and Wood-based Products |
|
|
D 3278-96(2004)e01 |
Test Methods for Flash Point of Liquids by Small |
|
Scale Closed-cup Apparatus |
|
|
D 3462/ D3462M-10a |
Specification for Asphalt Shingles Made from Glass |
|
Felt and Surfaced with Mineral Granules |
|
|
D 3468-99 (2006)e1 |
Specification for Liquid-applied Neoprene and |
|
Chlorosulfonated Polyethylene Used in Roofing and |
|
|
Waterproofing |
|
|
D 3679-09a |
Specification for Rigid Poly [Vinyl Chloride (PVC) |
|
Siding] |
|
|
D 3689-07 |
Method for Testing Individual Piles Under Static |
|
Axial Tensile Load |
|
|
D 3737-09 |
Practice for Establishing Allowable Properties for |
|
Structural Glued Laminated Timber (Glulam) |
|
|
D 3746-85 (2008) |
Test Method for Impact Resistance of Bituminous |
|
Roofing Systems |
|
|
D 3747-79 (2007) |
Specification for Emulsified Asphalt Adhesive for |
|
Adhering Roof Insulation |
|
|
D 3909-97b (2004)e01 |
Specification for Asphalt Roll Roofing (Glass Felt) |
|
Surfaced with Mineral Granules |
|
|
D 3957-09 |
Standard Practices for Establishing Stress Grades |
|
for Structural Members Used in Log Buildings |
|
|
D 4022-07 |
Specification for Coal Tar Roof Cement, Asbestos |
|
Containing |
|
|
D 4272-09 |
Test Method for Total Energy Impact of Plastic |
|
Films by Dart Drop |
|
|
D 4318-10 |
Test Methods for Liquid Limit, Plastic Limit and |
|
Plasticity Index of Soils |
|
|
D 4434/D 4434M-09 |
Specification for Poly (Vinyl Chloride) Sheet |
|
Roofing |
|
|
D 4479-07 |
Specification for Asphalt Roof Coatings- |
|
Asbestos-free |
|
|
D 4586-07 |
Specification for Asphalt Roof Cement-Asbestos-free |
|
D 4601-04 |
Specification for Asphalt-coated Glass Fiber Base |
|
Sheet Used in Roofing |
|
|
D 4637/D 4637M-10 |
Specification forEPDMSheet Used in Single-ply |
|
Roof Membrane |
|
|
D 4829-08a |
Test Method for Expansion Index of Soils |
|
D 4869-05e01 |
Specification for Asphalt-saturated (Organic Felt) |
|
Underlayment Used in Steep Slope Roofing |
|
|
D 4897/D 4897M-01(2009) |
Specification for Asphalt-coated Glass Fiber |
|
Venting Base Sheet Used in Roofing |
|
|
D 4945-08 |
Test Method for High-strain Dynamic Testing of |
|
Piles |
|
|
D 4990-97a (2005)e1 |
Specification for Coal Tar Glass Felt Used in |
|
Roofing and Waterproofing. |
|
|
D 5019-07a |
Specification for Reinforced Nonvulcanized |
|
Polymeric Sheet Used in Roofing Membrane |
|
|
D 5055-10 |
Specification for Establishing and Monitoring |
|
Structural Capacities of Prefabricated Wood I-joists |
|
|
D 5456-10 |
Specification for Evaluation of Structural |
|
Composite Lumber Products |
|
|
D 5516-09 |
Test Method of Evaluating the Flexural Properties |
|
of Fire-retardant-treated Softwood Plywood |
|
|
Exposed to the Elevated Temperatures |
|
|
D 5643-06 |
Specification for Coal Tar Roof Cement, Asbestos- |
|
free |
|
|
D 5664-10 |
Test Methods for Evaluating the Effects of Fire- |
|
retardant Treatment and Elevated Temperatures on |
|
|
Strength Properties of Fire-retardant-treated Lumber |
|
|
D 5665-99a (2006) |
Specification for Thermoplastic Fabrics Used in |
|
Cold-applied Roofing and Waterproofing |
|
|
D 5726-98 (2005) |
Specification for Thermoplastic Fabrics Used in |
|
Hot-applied Roofing and Waterproofing . |
|
|
D 6083-05e01 |
Specification for Liquid Applied Acrylic Coating |
|
Used in Roofing |
|
|
D 6162-00a (2008) |
Specification for Styrene-butadiene-styrene (SBS) |
|
Modified Bituminous Sheet Materials Using a |
|
|
Combination of Polyester and Glass Fiber |
|
|
Reinforcements |
|
|
D 6163-00 (2008) |
Specification for Styrene-butadiene-styrene (SBS) |
|
Modified Bituminous Sheet Materials Using Glass |
|
|
Fiber Reinforcements |
|
|
D 6164-05 e1 |
Specification for Styrene-butadiene-styrene (SBS) |
|
Modified Bituminous Sheet Metal Materials Using |
|
|
Polyester Reinforcements |
|
|
D 6222-08 |
Specification for Atactic Polypropylene (APP) |
|
Modified Bituminous Sheet Materials Using |
|
|
Polyester Reinforcements |
|
|
D 6223/D6223M-02(2009)e1 |
Specification for Atactic Polypropylene (APP) |
|
Modified Bituminous Sheet Materials Using a |
|
|
Combination of Polyester and Glass Fiber |
|
|
Reinforcements |
|
|
D 6298-05e1 |
Specification for Fiberglass Reinforced Styrene- |
|
butadiene-styrene (SBS) Modified Bituminous |
|
|
Sheets with a Factory Applied Metal Surface |
|
|
D 6305-08 |
Practice for Calculating Bending Strength Design |
|
Adjustment Factors for Fire-retardant-treated |
|
|
Plywood Roof Sheathing |
|
|
D 6380-03 (2009) |
Standard Specification for Asphalt Roll Roofing |
|
(Organic) Felt |
|
|
D 6509/D6509M-09 |
Standard Specification for Atactic Polypropylene |
|
(APP) Modified Bituminous base Sheet Materials |
|
|
Using Glass Fiber Reinforcements |
|
|
D 6694-08 |
Standard Specification for Liquid-applied Silicone |
|
Coating Used in Spray Polyurethane Foam Roofing |
|
|
D 6754/D6754M-10 |
Standard Specification for Ketone Ethylene Ester |
|
Based Sheet Roofing |
|
|
D 6757-07 |
Standard Specification for Inorganic Underlayment |
|
for Use with Steep Slope Roofing Products |
|
|
D 6841-08 |
Standard Practice for Calculating Design Value |
|
Treatment Adjustment Factors for Fire-retardant- |
|
|
treated Lumber |
|
|
D 6878-08e1 |
Standard Specification for Thermoplastic Polyolefin |
|
Based Sheet Roofing |
|
|
D 6947-07 |
Standard Specification for Liquuid Applied |
|
Moisture Cured Polyurethane Coating Used in |
|
|
Spray Polyurethane Foam Roofing System |
|
|
D 7158-08d |
Standard Test Method for Wind Resistance of |
|
Sealed Asphalt Shingles (Uplift Force/Uplift |
|
|
Resistance Method |
|
|
E 84-10b |
Test Methods for Surface Burning Characteristics of |
|
Building Materials |
|
|
E 90-09 |
Test Method for Laboratory Measurement of |
|
Airborne Sound Transmission Loss of Building |
|
|
Partitions and Elements |
|
|
E 96/E 96M-05 |
Test Method for Water Vapor Transmission of |
|
Materials |
|
|
E 108-10a |
Test Methods for Fire Tests of Roof Coverings |
|
E 119-10b |
Test Methods for Fire Tests of Building |
|
Construction and Materials |
|
|
E 136-09b |
Test Method for Behavior of Materials in a Vertical |
|
Tube Furnace at 750°C |
|
|
E 330-02 (2010) |
Test Method for Structural Performance of Exterior |
|
Windows, Curtain Walls and Doors by Uniform |
|
|
Static Air Pressure Difference |
|
|
E 331-00 (2009) |
Test Method for Water Penetration of Exterior |
|
Windows, Skylights, Doors and Curtain Walls by |
|
|
Uniform Static Air Pressure Difference |
|
|
E 492-09 |
Test Method for Laboratory Measurement of Impact |
|
Sound Transmission Through Floor-ceiling |
|
|
Assemblies Using the Tapping Machine |
|
|
E 605-93 (2006) |
Test Method for Thickness and Density of Sprayed |
|
Fire-resistive Material (SFRM) Applied to |
|
|
Structural Members. |
|
|
E 681-09 |
Test Methods for Concentration Limits of |
|
Flammability of Chemical Vapors and Gases |
|
|
E 736-00 (2006) |
Test Method for Cohesion/Adhesion of Sprayed |
|
Fire-resistive Materials Applied to Structural |
|
|
Members |
|
|
E 814-10 |
Test Method of Fire Tests of Through-penetration |
|
Firestops |
|
|
E 970-10 |
Test Method for Critical Radiant Flux of Exposed |
|
Attic Floor Insulation Using a Radiant Heat Energy |
|
|
Source |
|
|
E 1300-09a |
Practice for Determining Load Resistance of Glass |
|
in Buildings. |
|
|
E 1354-10a |
Standard Test Method for Heat and Visible Smoke |
|
Release Rates for Materials and Products Using an |
|
|
Oxygen Consumption Calorimeter |
|
|
E 1592-05 |
Test Method for Structural Performance of Sheet |
|
Metal Roof and Siding Systems by Uniform Static |
|
|
Air Pressure Difference |
|
|
E 1602-03 (2010)e1 |
Guide for Construction of Solid Fuel-burning |
|
Masonry Heaters |
|
|
E 1886-05 |
Test Method for Performance of Exterior Windows, |
|
Curtain Walls, Doors and Storm Shutters Impacted |
|
|
by Missiles and Exposed to Cyclic Pressure |
|
|
Differentials |
|
|
E 1966-07 |
Test Method for Fire-resistant Joint Systems. |
|
E 1996-09 |
Specification for Performance of Exterior Windows, |
|
Glazed Curtain Walls, Doors and Impact Protective |
|
|
Systems Impacted by Windborne Debris in |
|
|
Hurricanes |
|
|
E 2072-10 |
Standard Specification for Photoluminescent |
|
(Phosphorescent) Safety Markings |
|
|
E 2273-03 |
Standard Test Method for Determining the Drainage |
|
Efficiency of Exterior Insulation and Finish |
|
|
Systems (EIFS) Clad Wall Assemblies |
|
|
E 2307-10 |
Standard Test Method for Determining Fire |
|
Resistance of Perimeter Fire Barrier Systems Using |
|
|
Intermediate-scale, Multistory Test Apparatus |
|
|
E 2404-10 |
Standard Practice for Specimen Preparation and |
|
Mounting of Textile, Paper or Vinyl Wall or Ceiling |
|
|
Coverings to Assess Surface Burning |
|
|
Characteristics |
|
|
E 2568-09e1 |
Standard Specification for PB Exterior Insulation |
|
and Finish Systems (EIFS) |
|
|
E 2570-07 |
Standard Test Method for Evaluating Water- |
|
resistive Barrier (WRB) Coatings Used Under |
|
|
Exterior Insulation and Finish Systems (EIFS) for |
|
|
EIFS with Drainage |
|
|
E 2573-07a |
Standard Practice for Specimen Preparation and |
|
Mounting of Site-fabricated Stretch Systems to |
|
|
Assess Surface Burning Characteristics |
|
|
F 547-06 |
Terminology of Nails for Use with Wood and |
|
Wood-based Materials |
|
|
F 1346-91 (2003) |
Performance Specification for Safety Covers and |
|
Labeling Requirements for All Covers for |
|
|
Swimming Pools, Spas and Hot Tubs |
|
|
F 1667-10 |
Specification for Driven Fasteners: Nails, Spikes |
|
and Staples |
|
|
F 2006-10 |
Standard/Safety Specification for Window Fall |
|
Prevention Devices for NonemergencyEscape |
|
|
(Egress) and Rescue (Ingress) Windows |
|
|
F 2090-10 |
Specification for Window Fall Prevention Devices |
|
with Emergency Escape (Egress) Release |
|
|
Mechanisms |
|
|
F 2200-05 |
Standard Specification for Automated Vehicular |
|
Gate Construction |
|
|
G 152-06 |
Practice for Operating Open Flame Carbon Arc |
|
Light Apparatus for Exposure of Nonmetallic |
|
|
Materials |
|
|
G 154-06 |
Practice for Operating Fluorescent Light Apparatus |
|
for UV Exposure of Nonmetallic Materials |
|
|
G 155-05a |
Practice for Operating Xenon Arc Light Apparatus |
|
for Exposure of Nonmetallic Materials |
The Association of the Wall and Ceiling Industries International
513 West Broad Street, Suite 210
Falls Church, VA 22046
|
AWCI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
12-B-05 |
Technical Manual 12-B Standard Practice for the Testing and |
|
Inspection of Field Applied Thin Film Intumescent Fire-resistive |
|
|
Materials; an Annotated Guide, Second Edition |
American Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
|
AWPA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
C1-03 |
All Timber Products-Preservative Treatment by Pressure |
|
Processes |
|
|
M4-06 |
Standard for the Care of Preservative-treated Wood Products |
|
U1-10 |
USE CATEGORY SYSTEM: User Specification for Treated |
|
Wood Except Section 6, Commodity Specification H |
American Welding Society
550 N.W. LeJeune Road
Miami, FL 33126
|
AWS |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
D1.1-10 |
Structural Welding Code-Steel |
|
D1.3-08 |
Structural Welding Code-Sheet Steel |
|
D1.4-05 |
Structural Welding Code-Reinforcing Steel |
Builders Hardware Manufacturers' Association
355 Lexington Avenue, 17th Floor
New York, NY 10017-6603
|
BHMA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
A 156.10-05 |
Power Operated Pedestrian Doors |
|
A 156.19-07 |
Standard for Power Assist and Low Energy Operated Doors |
Canadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6
|
CGSB |
|
|
Standard |
|
|
Reference |
|
|
Number |
Title |
|
37-GP-52M (1984) |
Roofing and Waterproofing Membrane, Sheet |
|
Applied, Elastomeric |
|
|
37-GP-56M (1985) |
Membrane, Modified, Bituminous, Prefabricated |
|
and Reinforced for Roofing-with December 1985 |
|
|
Amendment |
|
|
CAN/CGSB 37.54-95 |
Polyvinyl Chloride Roofing and Waterproofing |
|
Membrane |
Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
|
CPA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
ANSI A135.4-2004 |
Basic Hardboard |
|
ANSI A135.5-2004 |
Prefinished Hardboard Paneling |
|
ANSI A135.6-2006 |
Hardboard Siding |
Consumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814-4408
|
CPSC |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
16 CFR Part 1201(1977) |
Safety Standard for Architectural Glazing |
|
Material |
|
|
16 CFR Part 1209 (1979) |
Interim Safety Standard for Cellulose |
|
Insulation |
|
|
16 CFR Part 1301(1977) |
Ban of Unstable Refuse Bins |
|
16 CFR Part 1404 (1979) |
Cellulose Insulation |
|
16 CFR Part 1500 (1991) |
Hazardous Substances and Articles; |
|
Administration and Enforcement |
|
|
Regulations |
|
|
16 CFR Part 1500.44 (2001) |
Method for Determining Extremely |
|
Flammable and Flammable Solids |
|
|
16 CFR Part 1507 (2001) |
Fireworks Devices |
|
16 CFR Part 1630 (2000) |
Standard for the Surface Flammability of |
|
Carpets and Rugs |
Canadian Standards Association
5060 Spectrum Way, Suite 100
Mississauga, Ontario, L4W 5N6 Canada
|
CSA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
101/I.S.2/A440-08 |
Specifications for Windows, Doors and Unit |
|
Skylights |
Cedar Shake and Shingle Bureau
P.O. Box 1178
Sumas, WA 98295-1178
|
CSSB |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
CSSB-97 |
Grading and Packing Rules for Western Red Cedar Shakes |
|
and Western Red Shingles of the Cedar Shake and Shingle |
|
|
Bureau |
Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
|
DASMA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
ANSI/DASMA 107-1997 |
|
|
(R2004) |
Room Fire Test Standard for Garage Doors Using |
|
Foam Plastic Insulation |
|
|
108-05 |
Standard Method for Testing Sectional Garage |
|
Doors and Rolling Doors: Determination of |
|
|
Structural Performance Under Uniform Static Air |
|
|
Pressure Difference |
|
|
115-05 |
Standard Method for Testing Sectional Garage |
|
Doors and Rolling Doors: Determination of |
|
|
Structural Performance Under Missile Impact and |
|
|
Cyclic Wind Pressure |
U.S. Department of Commerce
National Institute of Standards and Technology
1401 Constitution Avenue, NW
Washington, DC 20230
|
DOC |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
PS-1-07 |
Structural Plywood |
|
PS-2-04 |
Performance Standard for Wood-based Structural-use |
|
Panels |
|
|
PS 20-05 |
American Softwood Lumber Standard |
U.S. Department of Labor
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
|
DOL Standard reference number |
Title |
|
29 CFR Part 1910.1000 (1974) |
Air Contaminants |
U.S. Department of Transportation
c/o Superintendent of Documents
1200 New Jersey Avenue, SE
Washington, DC 20402-9325
|
DOTn |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
49CFRParts 100-185-2005 |
Hazardous Materials Regulations |
|
49 CFR Parts 173.137 |
|
|
(2005) |
Shippers-General Requirements for Shipments |
|
and Packaging-Class 8-Assignment of Packing |
|
|
Group |
|
|
49 CFR-1998 |
Specification of Transportation of Explosive and |
|
Other Dangerous Articles, |
|
|
UN 0335, UN 0336 Shipping Containers |
European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
|
EN |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
EN 1081-98 |
Resilient Floor Coverings-Determination of the Electrical |
|
Resistance |
Federal Emergency Management Agency
Federal Center Plaza
500 C Street S.W.
Washington, DC 20472
|
FEMA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
FIA-TB11-01 |
Crawlspace Construction for Buildings Located in |
|
Special Flood Hazard Areas |
Factory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P.O. Box 7500
Johnson, RI 02919
|
FM |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
4450 (1989) |
Approval Standard for Class 1 Insulated Steel Deck |
|
Roofs-with Supplements through July 1992 |
|
|
4470 (2010) |
Approval Standard for Class 1 Roof Covers |
|
4474 (04) |
Evaluating the Simulated Wind Uplift Resistance of Roof |
|
Assemblies Using Static Positive and/or Negative |
|
|
Differential Pressures |
|
|
4880 (2010) |
American National Standard for Evaluating Insulated Wall |
|
or Wall and Roof/ Ceiling Assemblies, Plastic Interior |
|
|
Finish Materials, Plastic Exterior Building Panels, |
|
|
Wall/Ceiling Coating Systems, Interior and Exterior Finish |
|
|
Systems |
Gypsum Association
810 First Street N.E. #510
Washington, DC 20002-4268
|
GA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
GA 216-10 |
Application and Finishing of Gypsum Panel Products |
|
GA 600-09 |
Fire-resistance Design Manual, 18th Edition |
Hardwood Plywood Veneer Association
1825 Michael Faraday Drive
Reston, VA 20190-5350
|
HPVA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
HP-1-2009 |
Standard for Hardwood and Decorative Plywood |
U.S. Department of Housing and Urban Development
451 7th Street, SW,
Washington, DC 20410
|
HUD |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
HUD 24 CFR Part 3280 (1994) |
Manufactured Home Construction and |
|
Safety Standards |
International Code Council, Inc.
500 New Jersey Ave, NW 6th Floor
Washington, DC 20001
|
ICC |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
ICC/ANSI A117.1-09 |
Accessible and Usable Buildings and Facilities |
|
ICC 300-07 |
ICC Standard on Bleachers, Folding and Telescopic |
|
Seating and |
|
|
ICC 400-07 |
Standard on Design and Construction of Log |
|
Structures |
|
|
ICC 500-08 |
ICC/NSSA Standard on the Design and |
|
Construction of Storm |
|
|
ICC 600-08 |
Standard for Residential Construction in High Wind |
|
Regions |
|
|
IEBC - 09 |
International Existing Buildings Code |
|
IECC-09 |
International Energy Conservation Code (adoption |
|
includes only section 101 of chapter 1 and chapters |
|
|
2 through 6) |
|
|
|
|
|
IFGC-09 |
International Fuel Gas Code (including ICC |
|
Emergency Amendment changing IFGC Sections |
|
|
406.7) |
|
|
SBCCI SSTD 11-99 |
Test Standard for Determining Wind Resistance of |
|
Concrete or Clay Roof Tiles |
International Organization for Standardization
ISO Central Secretariat,
1 ch, de la Voie-Creuse,
Case Postale 56
CH-1211 Geneva 20, Switzerland
|
ISO |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
ISO 8115-86 |
Cotton Bales-Dimensions and Density |
National Association of Architectural Metal Manufacturers,
800 Roosevelt Road,
Bldg. C, Suite 312
Glen Ellyn, IL 60137
|
NAAMM |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
FP 1001-07 |
Guide Specifications for Design of Metal Flag Poles |
National Concrete Masonry Association,
13750 Sunrise Valley,
Herndon, VA 22071-4662
|
NCMA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
TEK5-08 |
Details for Concrete Masonry Fire Walls |
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
|
NFPA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
10-10 |
Portable Fire Extinguishers |
|
11-10 |
Low Expansion Foam |
|
12-08 |
Carbon Dioxide Extinguishing Systems |
|
12A-04 |
Halon 1301 Fire Extinguishing Systems |
|
13-10 |
Installation of Sprinkler Systems (including TIA 10-2) |
|
13D-10 |
Installation of Sprinkler Systems in One- and Two- |
|
family Dwellings and Manufactured Homes |
|
|
(including TIA 10-2) |
|
|
13R-10 |
Installation of Sprinkler Systems in Residential |
|
Occupancies Up to and Including Four Stories in |
|
|
Height (including TIA 10-2) |
|
|
14-10 |
Installation of Standpipe and Hose System |
|
16-07 |
Installation of Foam-water Sprinkler and Foam- |
|
water Spray Systems |
|
|
17-09 |
Dry Chemical Extinguishing Systems |
|
17A-09 |
Wet Chemical Extinguishing |
|
20-10 |
Installation of Stationary Pumps for Fire Protection |
|
30-08 |
Flammable and Combustible Liquids Code |
|
31-06 |
Installation of Oil-burning Equipment |
|
32-07 |
Dry Cleaning Plants |
|
40-11 |
Storage and Handling of Cellulose Nitrate Film |
|
58-11 |
Liquefied Petroleum Gas Code |
|
61-08 |
Prevention of Fires and Dust Explosions in |
|
Agricultural and Food Product Facilities |
|
|
|
|
|
|
|
|
70-11 |
National Electrical Code (including TIA 11-1) |
|
|
|
|
72-10 |
National Fire Alarm and SignalingCode |
|
80-10 |
Fire Doors and Other Opening Protectives |
|
85-07 |
Boiler and Combustion System Hazards Code |
|
(Note: NFPA 8503 has been incorporated into |
|
|
NFPA 85) |
|
|
92B-09 |
Smoke Management Systems in Malls, Atria and |
|
Large Spaces |
|
|
99-05 |
Standard for Health Care Facilities |
|
105-10 |
Standard for the Installation of Smoke Door |
|
Assemblies |
|
|
110-10 |
Emergency and Standby Power Systems |
|
111-10 |
Stored Electrical Energy Emergency and Standby |
|
Power Systems |
|
|
120-10 |
Coal Preparation Plants |
|
170-09 |
Standard for Fire Safety and Emergency Symbols |
|
211-10 |
Chimneys, Fireplaces, Vents and Solid Fuel- |
|
burning |
|
|
252-08 |
Standard Methods of Fire Tests of Door Assemblies |
|
253-06 |
Test for Critical Radiant Flux of Floor Covering |
|
Systems Using a Radiant Heat Energy Source |
|
|
257-07 |
Standard for Fire Test for Window and Glass Block |
|
Assemblies |
|
|
259-08 |
Test Method for Potential Heat of Building |
|
Materials |
|
|
265-07 |
Method of Fire Tests for Evaluating Room Fire |
|
Growth Contribution of Textile Wall Coverings on |
|
|
Full Height Panels and Walls |
|
|
268-07 |
Standard Test Method for Determining Ignitibility |
|
of Exterior Wall Assemblies Using a Radiant Heat |
|
|
Energy Source |
|
|
285-06 |
Standard Method of Test for the Evaluation of |
|
Flammability Characteristics of Exterior Nonload- |
|
|
bearingWall Assemblies Containing Combustible |
|
|
Components |
|
|
286-06 |
Standard Method of Fire Test for Evaluating |
|
Contribution of Wall and Ceiling Interior Finish to |
|
|
Room Fire Growth |
|
|
288-07 |
Standard Method of Fire Tests of Floor Fire Door |
|
Assemblies Installed Horizontally in Fire- |
|
|
resistance-rated Floor Systems |
|
|
409-11 |
Aircraft Hangars |
|
418-06 |
Standard for Heliports |
|
484-09 |
Combustible Metals |
|
654-06 |
Prevention of Fire & Dust Explosions from the |
|
Manufacturing, Processing and Handling of |
|
|
Combustible Particulate Solids |
|
|
655-07 |
Prevention of Sulfur Fires and Explosions |
|
664-07 |
Prevention of Fires and Explosions in Wood |
|
Processing and Woodworking Facilities |
|
|
701-10 |
Standard Methods of Fire Tests for Flame- |
|
propagation of Textiles and Films |
|
|
704-07 |
Standard System for the Identification of the |
|
Hazards of Materials for Emergency Response |
|
|
1124-06 |
Manufacture, Transportation and Storage of |
|
Fireworks and Pyrotechnic Articles |
|
|
2001-08 |
Clean Agent Fire Extinguishing Systems |
Precast Prestressed Concrete Institute
175 W. Jackson Boulevard, Suite 500
Chicago, IL 60604-6938
|
PCI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
MNL 124-89 |
Design for Fire Resistance of Precast Prestressed |
|
Concrete |
|
|
MNL 128-01 |
Recommended Practice for Glass Fiber Reinforced |
|
Concrete Panels |
Post-Tensioning Institute
8601 North Black Canyon Highway, Suite 103
Phoenix, AZ 85021
|
PTI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
PTI-2008 |
Standard Requirements for Analysis of Shallow Concrete |
|
Foundations on Expansive Soils, Third Edition |
|
|
PTI-2008 |
Standard Requirements for Design of Shallow Post- |
|
tensioned Concrete Foundation on Expansive Soils, Second |
|
|
Edition |
Rack Manufacturers Institute
8720 Red Oak Boulevard, Suite 201
Charlotte, NC 28217
|
RMI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
ANSI/MH16.1-08 |
Specification for Design, Testing and Utilization of |
|
Industrial Steel Storage Racks |
Steel Deck Institute,
P. O. Box 25
Fox River Grove, IL 60021
|
SDI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
ANSI/NC1.0-06 |
Standard for Noncomposite Steel Floor Deck |
|
ANSI/RD1.0-06 |
Standard for Steel Roof Deck |
Steel Joist Institute,
1173B London Links Drive
Forest, VA 24551
|
SJI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
CJ-1.0-06 |
Standard Specification for Composite Steel Joists, |
|
CJ-series |
|
|
JG-1.1-05 |
Standard Specification for Joist Girders |
|
K-1.1-05 |
Standard Specification for Open Web Steel Joists, |
|
K- series |
|
|
LH/DLH-1.1-05 |
Standard Specification for Longspan Steel Joists, |
|
LH-series and Deep Longspan Steel Joists, DLH- |
|
|
series |
Single-Ply Roofing Institute,
411 Waverly Oaks Road, Suite 331B,
Waltham, MA 02452
|
SPRI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
SPRI/ANSI/ES-1-03 |
Wind Design Standard for Edge Systems Used with |
|
Low Slope Roofing Systems |
|
|
RP-4-02 |
Wind Design Guide for Ballasted Single-ply |
|
Roofing Systems |
Telecommunications Industry Association
2500 Wilson Boulevard
Arlington, VA 22201-3834
|
TIA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
TIA-222-G-09 |
Structural Standards for Steel Antenna Towers and |
|
Antenna Supporting Structures including-Addendum 1, |
|
|
222-G-1, Dated 2007 |
The Masonry Society,
3970 Broadway, Unit 201-D,
Boulder, CO 80304-1135
|
TMS |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
0216-07 |
Standard Method for Determining Fire Resistance of |
|
Concrete and Masonry Construction Assemblies |
|
|
0302-07 |
Standard Method for Determining the Sound Transmission |
|
Class Rating for Masonry Walls |
|
|
402-08 |
Building Code Requirements for Masonry Structures |
|
602-08 |
Specification for Masonry Structures |
Truss Plate Institute,
218 N. Lee Street, Suite 312
Alexandria, VA 22314
|
TPI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
TPI 1-2007 |
National Design Standards for Metal-plate-connected |
|
Wood Truss Construction |
Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
|
UL Standard |
|
|
reference |
|
|
number |
Title |
|
9-09 |
Fire Tests of Window Assemblies |
|
10A-09 |
Tin Clad Fire Doors |
|
10B-08 |
Fire Tests of Door Assemblies |
|
10C-09 |
Positive Pressure Fire Tests of Door Assemblies |
|
14B-08 |
Sliding Hardware for Standard Horizontally-mounted Tin |
|
Clad Fire Doors |
|
|
14C-06 |
Swinging Hardware for Standard Tin Clad Fire Doors |
|
Mounted Singly and in Pairs |
|
|
103-10 |
Factory-built Chimneys, for Residential Type and Building |
|
Heating Appliances |
|
|
127-08 |
Factory-built Fireplaces |
|
199E-04 |
Outline of Investigation for Fire Testing of Sprinklers and |
|
Water Spray Nozzles for Protection of Deep Fat Fryers. |
|
|
217-06 |
Single and Multiple Station Smoke Alarms |
|
263-03 |
Standard for Fire Test of Building Construction and |
|
Materials |
|
|
268-09 |
Smoke Detectors for Fire Protective Signaling Systems |
|
300-05 |
Fire Testing of Fire Extinguishing Systems for Protection |
|
of Restaurant Cooking Areas |
|
|
305-97 |
Panic Hardware |
|
325-02 |
Door, Drapery, Gate, Louver and Window Operations and |
|
Systems-with Revisions through February 2006 |
|
|
555-2006 |
Fire Dampers |
|
555C-2006 |
Ceiling Dampers |
|
555S-99 |
Smoke Dampers-with Revisions through July 2006 |
|
580-2006 |
Test for Uplift Resistance of Roof Assemblies |
|
641-95 |
Type L Low-temperature Venting Systems |
|
710B-04 |
Recirculating Systems-with Revisions through April 2006 |
|
723-08 |
Standard for Test for Surface Burning Characteristics of |
|
Building Materials |
|
|
790-04 |
Standard Test Methods for Fire Tests of Roof Coverings |
|
793-08 |
Standards for Automatically Operated Roof Vents for |
|
Smoke and Heat |
|
|
864-03 |
Standards for Control Units and Accessories for Fire Alarm |
|
Systems-with Revisions through March 2006 |
|
|
924-06 |
Standard for Safety Emergency Lighting and Power |
|
Equipment |
|
|
1040-96 |
Fire Test of Insulated Wall Construction-with Revisions |
|
through June 2001 |
|
|
1256-02 |
Fire Test of Roof Deck Construction-with Revisions |
|
through January 2007 |
|
|
1479-03 |
Fire Tests of Through-penetration Firestops-with |
|
Revisions through April 2007 |
|
|
1482-10 |
Solid-fuel-type Room Heater |
|
1715-97 |
Fire Test of Interior Finish Material-with Revisions |
|
through March 2004 |
|
|
1777-07 |
Chimney Liners |
|
1784-01 |
Air Leakage Tests of Door Assemblies-with Revisions |
|
through December 2004 |
|
|
1897-04 |
Uplift Tests for Roof Covering Systems |
|
1975-06 |
Fire Test of Foamed Plastics Used for Decorative Purposes |
|
1994-04 |
Standard for Luminous Egress Path Marking Systems- |
|
with Revisions through February 2005 |
|
|
2017-08 |
Standards for General-purpose Signaling Devices and |
|
Systems |
|
|
2079-04 |
Tests for Fire Resistance of Building Joint Systems-with |
|
Revisions through March 2006 |
|
|
2200-98 |
Stationary Engine Generator Assemblies |
Underwriters Laboratories of Canada,
7 Underwriters Road,
Toronto, Ontario, Canada M1R3B4
|
ULC |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
CAN/ULC S102.2-2010 |
Standard Method of Test for Surface Burning |
|
Characteristics of Flooring, Floor Coverings and |
|
|
Miscellaneous Materials and Assemblies-with |
|
|
2000 Revisions |
United States Code,
c/o Superintendent of Documents
U.S. Government Printing Office,
Washington, DC 20402-9325
|
USC |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
10 U.S.C. Sections 18233(A)(1) and 18237-1994 |
|
|
18 USC Part 1, Ch.40 |
Importation, Manufacture, Distribution and Storage |
|
of Explosive Materials |
Window and Door Manufacturers Association
1400 East Touhy Avenue #470
Des Plaines, IL 60018
|
WDMA |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
AAMA/WDMA/CSA |
|
|
101/I.S.2/A440-08 |
Specifications for Windows, Doors and Unit |
|
Skylights |
Wire Reinforcement Institute, Inc.
942 Main Street, Suite 300
Hartford, CT 06103
|
WRI |
|
|
Standard |
|
|
reference |
|
|
number |
Title |
|
WRI/CRSI-81 |
Design of Slab-on-ground Foundations-with 1996 Update |
Effective:
03/01/2013
R.C.
119.032 review dates:
11/01/2016
Promulgated
Under: 119.03
Statutory
Authority:
3781.10(A)
Rule Amplifies:
3781.10,
3781.11,
3791.04
Prior
Effective Dates: 9/1/92, 2/1/93, 7/1/95, 7/1/97, 3/1/98, 7/1/98, 1/1/99,
12/1/00, 1/1/02, 3/1/05, 9/6/05, 3/1/06, 7/1/07, 1/1/08, 3/31/08(Emer.),
6/24/08, 1/1/09, 11/1/11, 3/15/12