1501.1 General. This chapter lists the codes and standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and the title. The application of the referenced standards shall be as specified in Section 102.5 of the building code.
1501.2 Referenced codes: When indicated in the OMC, the following codes refer to provisions in the listed chapters of the Administrative Code:
|
Referenced code |
Ohio Administrative Code chapters |
|
Building Code |
4101:1-1 to 4101:1-35 |
|
Fire Code |
1301:7-1 to 1301:7-7 |
|
Ohio Boiler and Pressure Vessel Rules |
4101:4-1 to 4101:4-10 |
|
Plumbing Code |
4101:3-1 to 4101:3-13 |
1501.3 Referenced Standards.
ACCAAir Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
|
Standard reference number |
Title |
|
Manual D-95 183-2007 |
Residential Duct Systems Peak Cooling and Heating Load Calculations in Buildings Except Low-Rise Residential Buildings |
AHRIAir-Conditioning, Heating and Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington, VA 22203
|
Standard reference number |
Title |
|
700-06 |
Purity Specifications for Fluorocarbon and Other Refrigerants |
ANSIAmerican National Standards Institute
11 West 42nd Street
New York, NY 10036
|
Standard reference number |
Title |
|
Z21.8-1994 (R2002) |
Installation of Domestic Gas Conversion Burners |
ASHRAEAmerican Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329
|
Standard reference number |
Title |
|
Handbook-2009 |
ASHRAE Fundamentals Handbook- |
|
15-2010 |
Safety Standard for Refrigeration Systems |
|
34-2010 |
Designation and Safety Classification of Refrigerants |
|
62.1-2010 |
Ventilation for Acceptable Indoor Air Quality |
|
62.2. -2010 |
Ventilation for Acceptable Indoor Air Quality in Low-Rise Residential Buildings |
|
170-2008 |
Ventilation of Health Care Facilities (with addendums a through h-2011) |
ASMEAmerican Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
|
Standard reference number |
Title |
|
B1.20.1-1983 (R2006) |
Pipe Threads, General Purpose (Inch |
|
B16.3-2006 |
Malleable Iron Threaded Fittings, Classes 150 & 300 |
|
B16.5-2009 |
Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24-. |
|
B16.9- 2007 |
Factory Made Wrought Steel Buttwelding Fittings |
|
B16.11-2009 |
Forged Fittings, Socket-welding and Threaded |
|
B16.15-2006 |
Cast Bronze Threaded Fittings |
|
B16.18-2001 (Reaffirmed 2005) |
Cast Copper Alloy Solder Joint Pressure Fittings |
|
B16.22-2001 (Reaffirmed 2005) |
Wrought Copper and Copper Alloy Solder Joint Pressure Fittings |
|
B16.23-2002 (Reaffirmed 2006) |
Cast Copper Alloy Solder Joint Drainage Fittings DWV |
|
B16.24-2006 |
Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900, 1500 and |
|
B16.26-2006 |
Cast Copper Alloy Fittings for Flared Copper Tubes |
|
B16.28-1994 |
Wrought Steel Buttwelding Short Radius Elbows and Returns |
|
B16.29-2007 |
Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings- |
|
B31.9-2010 |
Building Services Piping |
|
BPVC- 2010 |
Boiler & Pressure Vessel Code |
|
BPVC Section IX- 2010 |
Welding and Brazing Qualifications |
|
CSD-1- 2009 |
Controls and Safety Devices for Automatically Fired Boilers |
ASSEAmerican Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake, OH 44145
|
Standard reference number |
Title |
|
1017-09 |
Temperature Actuated Mixing Valves for Hot Water Distribution Systems |
ASTMASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
|
Standard reference number |
Title |
|
A 53/A 53M-10 |
Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless |
|
A 106/A106M-10 |
Specification for Seamless Carbon Steel Pipe for High-Temperature Service |
|
A 126-04 (2009) |
Specification for Gray Iron Castings for Valves, Flanges and Pipe Fittings |
|
A 254-97 (2007) |
Specification for Copper Brazed Steel Tubing |
|
A 420/A 420M-10 |
Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Low-Temperature Service |
|
A 539-99 |
Specification for Electric-Resistance-Welded Coiled Steel Tubing for Gas and Fuel Oil Lines |
|
B 32-08 |
Specification for Solder Metal |
|
B 42-10 |
Specification for Seamless Copper Pipe, Standard Sizes |
|
B 43-09 |
Specification for Seamless Red Brass Pipe, Standard |
|
B 68-02 |
Specification for Seamless Copper Tube, Bright Annealed |
|
B 75-02 |
Specification for Seamless Copper |
|
B 88-09 |
Specification for Seamless Copper Water |
|
B 135-10 |
Specification for Seamless Brass Tube |
|
B 251-10 |
Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube |
|
B 280-08 |
Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service |
|
B 302-07 |
Specification for Threadless Copper Pipe, Standard |
|
B 813-10 |
Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube |
|
C 315-07 |
Specification for Clay Flue Liners and Chimney Pots |
|
C 411-05 |
Test Method for Hot-surface Performance of High-temperature Thermal Insulation |
|
D 56-05 (2010) |
Test Method for Flash Point by Tag Closed Tester |
|
D 93-10a |
Test Method for Flash Point of Pensky-Martens Closed Cup Tester |
|
D 1527-99(2005) |
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80 |
|
D 1693-08 |
Test Method for Environmental Stress-Cracking of Ethylene Plastics |
|
D 1785-06 |
Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe, Schedules 40, 80 and 120 |
|
D 2235-04 |
Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings |
|
D 2241-09 |
Specification for Poly (Vinyl Chloride)(PVC) Pressure-rated Pipe (SDR-Series |
|
D 2282-99(2005) |
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR) |
|
D 2412-10 |
Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-plate Loading |
|
D 2447-03 |
Specification for Polyethylene (PE) Plastic Pipe, Schedules 40 and 80, Based on Outside Diameter |
|
D 2466-06 |
Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 40 |
|
D 2467-06 |
Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 80 |
|
D 2468-96a |
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40 |
|
D 2513-09a |
Specification for Thermoplastic Gas Pressure Pipe, Tubing, and |
|
D 2564-04(2009)e01 |
Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems |
|
D 2657-07 |
Standard Practice for Heat Fusion Joining ofPolyolefinPipe and Fittings |
|
D 2683-10 |
Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing |
|
D 2837-08 |
Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials or Pressure Design Basis for Thermoplastic Pipe Products |
|
D 2846/D 2846M-09b |
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold Water Distribution Systems |
|
D 2996-01(2007)e01 |
Specification for Filament-wound Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Pipe |
|
D 3035-08 |
Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter |
|
D 3278-96(2004)e01 |
Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus |
|
D 3261-10a |
Standard Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and |
|
D 3309-96a(2002) |
Specification for Polybutylene (PB) Plastic Hot and Cold Water Distribution Systems |
|
D 3350-10 |
Specification for Polyethylene Plastics Pipe and Fittings Materials |
|
E 84-10b |
Test Method for Surface Burning Characteristics of Building Materials |
|
E 119-10b |
Test Method for Fire Tests of Building Construction and |
|
E 136-09b |
Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C |
|
E 814-10 |
Test Method for Fire Tests of Through-penetration Fire |
|
E 1509-04 |
Specification for Room Heaters, Pellet Fuel-burning |
|
E 2231-09 |
Standard Practice For Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surface Burning Characteristics |
|
E 2336-04 (2009) |
Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems |
|
F 438-09 |
Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40 |
|
F 439-09 |
Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 |
|
F 441/F 441M-09 |
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and |
|
F 442/F 442M-09 |
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR). |
|
F 493-10 |
Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings |
|
F 876-10 |
Specification forCrosslinkedPolyethylene (PEX) Tubing |
|
F 877-07 |
Specification for Crosslinked Polyethylene (PEX) Plastic Hot and Cold Water Distribution Systems. |
|
F 1055-98(2006) |
Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene Pipe and |
|
F 1281-07 |
Specification for Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Pressure Pipe |
|
F 1282-10 |
Standard Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe |
|
F 1476-07 |
Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications |
|
F 1924-05 |
Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing |
|
F 1974-09 |
Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe |
|
F 2389-10 |
Specification for Pressure-Rated Polypropylene Piping Systems |
|
F 2623-08 |
Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing1 |
AWSAmerican Welding Society
550 N.W. LeJeune Road P.O. Box 351040
Miami, FL 33135
|
Standard reference number |
Title |
|
A5.8-2004 |
Specifications for Filler Metals for Brazing and Braze Welding. |
AWWAAmerican Water Work Association
6666 West Quincy Avenue
Denver, CO 80235
|
Standard reference number |
Title |
|
C110/A21.10- 08 |
Standard for Ductile Iron & Gray Iron Fittings, 2 inches Through 48 inches for Water |
|
C115/A21.15-05 |
Standard for Flanged Ductile-iron Pipe with Ductile Iron or Grey-iron Threaded Flanges |
|
C151/A21.51-09 |
Standard for Ductile-Iron Pipe, Centrifugally Cast for Water |
|
C153/A21.53-06 |
Standard for Ductile-Iron Compact Fittings for Water Service |
CSACanadian Standards Association
5060 Spectrum Way Mississauga,
Ontario, Canada L4W 5N6
|
Standard reference number |
Title |
|
B137.9-M91 CAN/CSA |
Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-Pipe Systems |
|
B137.10-05 |
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure-Pipe Systems |
|
ANSI CSA America FC1-04 |
Stationary Fuel Cell Power Systems |
DOLDepartment of Labor Occupational Safety and Health Administration
c/o Superintendent of Documents
US Government Printing Office
Washington, DC 20402-9325
|
Standard reference number |
Title |
|
29CFRPart 1910.1000 (1974) |
Air Contaminants |
|
29CFRPart 1910. 1025 |
Toxic and Hazardous Substances |
FSFederal Specifications*
General Services Administration
7th & D Streets Specification Section, Room 6039
Washington, DC 20407
|
Standard reference number |
Title |
|
WW-P-325B (1976) |
Pipe, Bends, Traps, Caps and Plugs; Lead (for Industrial Pressure and Soil and Waste Applications |
*Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325.
ICCInternational Code Council, Inc.
500 New Jersey Ave, NW
6th FloorICC
Washington, DC 20001
|
Standard reference number |
Title |
|
IFGC-09 |
International Fuel Gas Code (including ICC Emergency Amendment changing IFGC Sections 406.7 ) |
IIAR International Institute of Ammonia Refrigeration
1110 North Glebe Road
Arlington, VA 22201
|
Standard reference number |
Title |
|
299 (with Addendum A-2005) |
Equipment, Design, and Installation of Ammonia Mechanical Refrigerating Systems |
MSSManufacturers Standardization Society of the Valve & Fittings Industry, Inc. 1
27 Park Street, N.E.
Vienna, VA 22180
|
Standard reference number |
Title |
|
SP-69-2003 |
Pipe Hangers and Supports-Selection and Application |
NAIMANorth American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310 Alexandria, VA 22314
|
Standard reference number |
Title |
|
AH116-02 |
Fibrous Glass Duct Construction Standards |
NFPANational Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
|
Standard reference number |
Title |
|
30A-08 |
Code for Motor Fuel-dispensing Facilities and Repair Garages |
|
31-06 |
Installation of Oil-burning Equipment |
|
37-10 |
Stationary Combustion Engines and Gas Turbines |
|
58-11 |
Liquefied Petroleum Gas Code |
|
69-08 |
Explosion Prevention Systems |
|
70-11 |
National Electrical Code |
|
72-10 |
National Fire Alarm and SignalingCode |
|
75-09 |
Protection of Information Technology Equipment |
|
82-09 |
Incinerators and Waste and Linen Handling Systems and Equipment |
|
85-07 |
Boiler and Combustion Systems Hazards Code |
|
91-10 |
Exhaust Systems for Air Conveying of Vapors, Gases, and Noncombustible Particulate Solids |
|
92B-09 |
Smoke Management Systems in Malls, Atria and Large Spaces |
|
211-10 |
Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances |
|
262-07 |
Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-handling Spaces |
|
704-07 |
Identification of the Hazards of Materials for Emergency Response |
|
853-10 |
Installation of Stationary Fuel Power Plants |
SMACNASheet Metal & Air Conditioning Contractors National Assoc., Inc.
4201 Lafayette Center Drive
Chantilly, VA 20151-1209
|
Standard reference number |
Title |
|
SMACNA/ANSI-2005 |
HVAC Duct Construction Standards-Metal and Flexible (2005) |
|
SMACNA-03 |
Fibrous Glass Duct Construction Standards |
ULUnderwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
|
Standard reference number |
Title |
|
17-08 |
Vent or Chimney Connector Dampers for Oil-fired Appliances |
|
103-10 |
Factory-built Chimneys, Residential Type and Building Heating Appliance |
|
127-08 |
Factory-built Fireplaces |
|
174-04 |
Household Electric Storage Tank Water Heaters-with Revisions through May 2006 |
|
181-05 |
Factory-made Air Ducts and Air Connectors-with Revisions through December 1998 |
|
181A-05 |
Closure Systems for Use with Rigid Air Ducts and Air Connectors-with Revisions through December 1998 |
|
181B-05 |
Closure Systems for Use with Flexible Air Ducts and Air Connectors-with Revisions through December 1998 |
|
207-01 |
Refrigerant-containing Components and Accessories, Nonelectrical-with Revisions through November 2004 |
|
263-03 |
Standard for Fire Test of Building Construction and Materials |
|
268-09 |
Smoke Detectors for Fire Prevention Signaling Systems |
|
268A-08 |
Smoke Detectors for Duct Applications |
|
343-08 |
Pumps for Oil-Burning Appliances |
|
391-10 |
Solid-fuel and Combination-fuel Central and Supplementary Furnaces |
|
412-04 |
Refrigeration Unit Coolers-with Revisions through February 2007 . |
|
471-10 |
Commercial Refrigerators and Freezers |
|
508-99 |
Industrial Control Equipment-with Revisions through July 2005 |
|
536-97 |
Flexible Metallic Hose-with Revisions through June 2003 |
|
555-06 |
Fire Dampers-with Revisions through January 2002. |
|
555C-06 |
Ceiling Dampers |
|
555S-99 |
Smoke Dampers-with Revisions through July 2006 |
|
586-09 |
High-efficiency, Particulate, Air Filter Units |
|
641-95 |
Type L Low-temperature Venting Systems-with Revisions through August 2005 |
|
710-95 |
Exhaust Hoods for Commercial Cooking Equipment-with Revisions through February 2007. |
|
710B-04 |
Recirculating Systems |
|
723-08 |
Standard for Test for Surface Burning Characteristics of Building Materials |
|
726-95 |
Oil-fired Boiler Assemblies-with Revisions through March 2006 |
|
727-06 |
Oil-fired Central Furnaces |
|
729-03 |
Oil-fired Floor Furnaces-with Revisions through January 1999 |
|
730-03 |
Oil-fired Wall Furnaces-with Revisions through January 1999 |
|
731-95 |
Oil-fired Unit Heaters-with Revisions through February 2006 |
|
732-95 |
Oil-fired Storage Tank Water Heaters-with Revisions through February 2005 |
|
737-07 |
Fireplace Stoves |
|
762-03 |
Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances |
|
791-06 |
Residential Incinerators. |
|
834-04 |
Heating, Water Supply and Power Boilers Electric-with Revisions through March 2006 |
|
858-05 |
Household Electric Ranges-with Revisions through April 2006 |
|
867-00 |
Electrostatic Air Cleaners-with Revisions through May 2004 |
|
875-09 |
Electric Dry Bath Heater |
|
896-93 |
Oil-burning Stoves-with Revisions through May 2004 |
|
900-04 |
Air Filter Units |
|
923-08 |
Microwave Cooking Appliances |
|
959-01 |
Medium Heat Appliance Factory-built Chimneys-with Revisions through September 2006 |
|
1240-05 |
Electric Commercial Clothes |
|
1261-01 |
Electric Water Heaters for Pools and Tubs-with Revisions through June 2004 |
|
1453-04 |
Electric Booster and Commercial Storage Tank Water Heaters-with Revisions through May 2006 |
|
1482-10 |
Solid-fuel Type Room Heaters |
|
1777-07 |
Chimney Liners . |
|
1812-09 |
Standard for Ducted Heat Recovery Ventilators |
|
1815-09 |
Standard for Nonducted Heat Recovery Ventilators |
|
1820-04 |
Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics |
|
1887-04 |
Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics |
|
1978-05 |
Grease Ducts |
|
1995-05 |
Heating and Cooling Equipment . |
|
2158-97 |
Electric Clothes Dryers-with Revisions through May 2004 |
|
2162-01 |
Outline of Investigation for Commercial Wood-fired Baking Ovens-Refractory Type |
|
2200-98 |
Stationery Engine Generator Assemblies |
|
2221-10 |
Tests of Fire Resistive Grease Duct Enclosure Assemblies |
Effective:
03/01/2013
R.C.
119.032 review dates:
11/01/2016
Promulgated
Under: 119.03
Statutory
Authority:
3781.10(A)
Rule Amplifies:
3781.10,
3781.11,
3791.04
Prior
Effective Dates: 7/1/82, 3/1/85, 3/1/86, 1/1/89, 9/1/92, 7/1/95, 2/1/96,
3/1/98, 7/1/98, 1/1/02, 1/1/04, 3/1/05, 9/6/05, 3/1/06, 7/1/07, 1/1/08,
3/31/08(Emer.), 6/24/08, 1/1/09,
11/1/11