Special purpose personnel elevators used for access to agricultural storage and processing facilities shall comply with ANSI A 17.1 -2000, Safety Code for Elevators and Escalators, with the following modifications:
(A) Change section 5.7.9, Locking Devices for Hoistway Doors or Gates, to read: “Hoistway doors or gates shall be provided with hoistway-door interlocks or with locking devices and electric contacts conforming to the requirements of section 2.12.”
(B) Section 5.7.19, add subsection 2.26. 1.5 -Inspection Operation with Open Door Circuits.
(C) Section 5.7.19, add subsection 2.26. 2.29 -Ascending Car Overspeed Protection Device.
(D) Section 5.7.19, add subsection 2.26. 2.30 -Unintended Car Movement Device.
(E) Section 5.7.19, add subsection 2.26. 12.3 -Braille.
Eff 1-1-04
Rule promulgated under: RC 119.03
Rule authorized by: RC 4105.011
Rule amplifies: RC 4105.011
RC 119.032 review dates: 10/01/07