Chapter 4101:8-3 Approved Standards

4101:8-3-01.2 Climatic and geographic design criteria.

301.2 Climatic and geographic design criteria. Buildings shall be constructed in accordance with the provisions of this code as limited by the provisions of this section. Additional criteria shall be established by the local jurisdiction and set forth in Table 301.2(1).

See Tables and Figures at http://www.com.state.oh.us/dic/Documents/ResidentialCodeboardchangestotheOBOA2004ResidentialCodeofOhio.pdf

TABLE 301.2(1) Climatic and Geographic Design Criteria

TABLE 301.2(2)Component and Cladding Loads for a Building with a Mean Roof Height of 30 Feet Located In Exposure B (Psf)

TABLE 301.2(3) Height and Exposure Adjustment Coefficients for Table 301.2(2)

FIGURE 301.2(1) Isolines of The 971/2 Percent Winter (December, January and February) Design Temperatures (& 176;F)

Figure 301.2(2) Seismic Design Categories – Site Class D

FIGURE 301.2(3) Weathering Probability Map for Concrete

FIGURE 301.2(4) Basic Wind Speeds for 50-Year Mean Recurrence Interval

FIGURE 301.2(5) Ground Snow Loads, Pg , for the United States (lb/ft2)

FIGURE 301.2(6) Termite Infestation Probability Map

FIGURE 301.2(7) Decay Probability Map

FIGURE 301.2(8) Component and Cladding Pressure Zones

Effective: 05/27/2006

R.C. 119.032 review dates: 05/27/2011

Promulgated Under: 119.03

Statutory Authority: 3781.10(A)

Rule Amplifies: 3781.10, 3781.11, 3791.04

4101:8-3-01.2.5 Freezing and thawing exposures.

301.2.5 Freezing and thawing exposures. Deleted, including all subsections.

Effective: 05/27/2006

R.C. 119.032 review dates: 05/27/2011

Promulgated Under: 119.03

Statutory Authority: 3781.10(A)

Rule Amplifies: 3781.10, 3781.11, 3791.04

4101:8-3-10.5 Replacement windows.

310.5 Replacement windows. Deleted

Effective: 05/27/2006

R.C. 119.032 review dates: 05/27/2011

Promulgated Under: 119.03

Statutory Authority: 3781.10(A)

Rule Amplifies: 3781.10, 3781.11, 3791.04

4101:8-3-17.1 Two-family dwellings.

317.1 Two-family dwellings. Dwelling units in two-family dwellings shall be separated from each other by wall and/or floor assemblies having not less than 1-hour fireresistance rating when tested in accordance with ASTM E 119. Fire-resistance-rated floor-ceiling and wall assemblies shall extend to and be tight against the exterior wall, and wall assemblies shall extend to the underside of the roof sheathing.

Exception: A fire resistance rating of 1/2 hour shall be permitted in buildings equipped throughout with an automatic sprinkler system installed in accordance with NFPA 13.

Effective: 05/27/2006

R.C. 119.032 review dates: 05/27/2011

Promulgated Under: 119.03

Statutory Authority: 3781.10(A)

Rule Amplifies: 3781.10, 3781.11, 3791.04

4101:8-3-17.2 Residential structures with more than two dwelling units.

317.2 Residential structures with more than two dwelling units. In structures with more than two dwelling units, each dwelling unit shall be separated from the adjacent unit by two one-hour fire-resistance-rated wall assemblies, or a common 2-hour fireresistance- rated wall when such wall does not contain plumbing or mechanical equipment, ducts or vents in the cavity of the common wall (penetrations of electrical outlet boxes shall be in accordance with Section 317.3 ).

Within any grouping of two units, the units may be separated by one-hour fire-resistancerated wall and/or floor assemblies when the grouping is separated from adjacent units or other groupings of two units by two one-hour fire-resistance rated wall assemblies or a single 2-hour wall constructed as indicated above.

When assemblies are required to be fire-resistance-rated, the supporting construction of such assemblies shall have an equal or greater fire-resistive rating.

Effective: 05/27/2006

R.C. 119.032 review dates: 05/27/2011

Promulgated Under: 119.03

Statutory Authority: 3781.10(A)

Rule Amplifies: 3781.10, 3781.11, 3791.04

4101:8-3-22 Accessibility.

322.1 Accessibility. Where there are four or more dwelling units or sleeping units in a single structure, the provisions of Chapter 11 of the OBC shall apply.

When non-required accessibility components are intended to be installed, they shall comply with the ANSI A 117.1 listed in Chapter 35 of the OBC to the extent of the installation.

Effective: 05/27/2006

R.C. 119.032 review dates: 05/27/2011

Promulgated Under: 119.03

Statutory Authority: 3781.10(A)

Rule Amplifies: 3781.10, 3781.11, 3791.04