602.3 Design and construction. Exterior walls of wood-frame construction shall be designed and constructed in accordance with the provisions of this chapter and Figures 602.3(1) and 602.3(2) or in accordance with AF&PA’s NDS. Components of exterior walls shall be fastened in accordance with Table 602.3(1) through 602.3(4). Exterior walls covered with foam plastic sheathing shall be braced in accordance with Section 602.10. Structural sheathing shall be fastened directly to structural framing members.
See Tables and Figures at http://www.com.state.oh.us/dic/Documents/ResidentialCodeboardchangestotheOBOA2004ResidentialCodeofOhio.pdf
TABLE 602.3(1) Fastener Schedule for Structural Members
TABLE 602.3(2) ALTERNATE ATTACHMENTS SPACINGc OF FASTENERS
TABLE 602.3(3) ALLOWABLE STUD SPACING FOR WOOD STRUCTURAL PANEL WALL SHEATHING
TABLE 602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING
TABLE 602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDS
FIGURE 602.3(1) Typical Wall, Floor and Roof Framing
FIGURE 602.3(2) Framing Details
Effective: 05/27/2006
R.C. 119.032 review dates: 05/27/2011
Promulgated Under: 119.03
Statutory Authority: 3781.10(A)
Rule Amplifies: 3781.10, 3781.11, 3791.04