4123:1-5-99 Table of standard materials and dimensions.

Where required by Chapter 4123:1-5 of the Administrative Code, the following table to this rule shall be used.

Table of standard materials and dimensions*

 

 

	

Material Distance of opening from hazard zone Maximum width of opening allowable Minimum gauge (U.S. Standard) or thickness Minimum height of guard from floor or platform level

Inches                                  Inches                                                                            Feet

Woven wire Under 4 *see table below No. 16 7

4-15 No. 12 7

Expanded metal Under 4 *see table below No. 18 7

No. 13 7

Perforated metal Under 4 *see table below No. 20 7

4-15 No. 14 7

Sheet metal Under 4 *see table below No. 22 7

4-15 No. 22 7

Wood or metal strip not crossed Under 4 *see table below Wood 3/4 Metal No. 16 7

4-15 Wood 3/4 Metal No. 16 7

Standard guard railing* Minimum 15 – – -

Maximum 20

 

	

Distance of opening from hazard zone (inches)

0.5 to 1.5 0.25

Over 1.5 to 2.5 0.3725

Over 2.5 to 3.5 0.5

Over 3.5 to 5.5 0.625

Over 5.5 to 6.5 0.75

Over 6.5 to 7.5 0.875

Over 7.5 to 12.5 1.25

Over 12.5 to 15.5 1.5

Over 15.5 to 17.5 1.875

Over 17.5 to 31.5 2.125

Effective: 04/10/2011

R.C. 119.032 review dates: 03/03/2010 and 03/01/2016

Promulgated Under: 119.03

Statutory Authority: 4121.12, 4121.121, 4121.13

Rule Amplifies: 4121.47

Prior Effective Dates: 1/1/86