Ohio Administrative Code Search
| Rule |
|---|
|
Rule 3745-66-43 | Financial assurance for facility closure.
...An owner or operator of each facility shall establish financial assurance for closure of the facility. The owner or operator shall choose from among the options specified in paragraphs (A) to (E) of this rule. (A) Closure trust fund. (1) An owner or operator may satisfy the requirements of this rule by establishing a closure trust fund which conforms to the requirements of paragraphs (A) to (A)(11)(b) of this rule ... |
|
Rule 3745-66-43 | Financial assurance for facility closure.
...An owner or operator of each facility shall establish financial assurance for closure of the facility. The owner or operator shall choose from among the following options: (A) Closure trust fund. (1) An owner or operator may satisfy the requirements of this rule by establishing a closure trust fund which conforms to the requirements of paragraph (A) of this rule and submitting an originally signed d... |
|
Rule 3745-66-43 | Financial assurance for facility closure.
...An owner or operator of each facility shall establish financial assurance for closure of the facility. The owner or operator shall choose from the options as specified in paragraphs (A) to (E) of this rule: (A) Closure trust fund. (1) An owner or operator may satisfy the requirements of this rule by establishing a closure trust fund which conforms to the requirements of paragraph (A) of this rule and ... |
|
Rule 3745-66-45 | Financial assurance for post-closure care.
...An owner or operator of each facility with a hazardous waste disposal unit shall establish financial assurance for post-closure care of the disposal units. (A) Post-closure trust fund. (1) An owner or operator may satisfy the requirements of this rule by establishing a post-closure trust fund which conforms to the requirements of paragraphs (A) to (A)(12)(b) of this rule and submitting an originally signed duplicat... |
|
Rule 3745-66-45 | Financial assurance for post-closure care.
...An owner or operator of each facility with a hazardous waste disposal unit shall establish financial assurance for post-closure care of the disposal units. (A) Post-closure trust fund. (1) An owner or operator may satisfy the requirements of this rule by establishing a post-closure trust fund which conforms to the requirements of paragraph (A) of this rule and submitting an originally signed duplica... |
|
Rule 3745-66-45 | Financial assurance for post-closure care.
...The owner or operator of a facility with a hazardous waste disposal unit shall establish financial assurance for post-closure care of the disposal units. (A) Post-closure trust fund. (1) The owner or operator may satisfy the requirements of this rule by establishing a post-closure trust fund which conforms to the requirements of paragraph (A) of this rule and submitting an originally signed duplicat... |
|
Rule 3745-66-47 | Liability requirements.
...(A) Coverage for sudden accidental occurrences. An owner or operator of a hazardous waste treatment, storage, or disposal facility, or a group of such facilities, shall demonstrate financial responsibility for bodily injury and property damage to third parties caused by sudden accidental occurrences arising from operations of the facility or group of facilities. The owner or operator shall have and maintain liability... |
|
Rule 3745-66-47 | Liability requirements.
...(A) Coverage for sudden accidental occurrences. An owner or operator of a hazardous waste treatment, storage, or disposal facility, or a group of such facilities, shall demonstrate financial responsibility for bodily injury and property damage to third parties caused by sudden accidental occurrences arising from operations of the facility or group of facilities. The owner or operator shall have an... |
|
Rule 3745-66-92 | Design and installation of new tank systems or components.
...(A) Owners or operators of new tank systems or components must ensure that the foundation, structural support, seams, connections, and pressure controls (if applicable) are adequately designed and that the tank system has sufficient structural strength, compatibility with the waste(s) to be stored or treated, and corrosion protection so that it will not collapse, rupture, or fail. The owner or operator must obtain a ... |
|
Rule 3745-66-92 | Design and installation of new tank systems or components.
...(A) Owners or operators of new tank systems or components shall ensure that the foundation, structural support, seams, connections, and pressure controls (if applicable) are adequately designed and that the tank system has sufficient structural strength, compatibility with the wastes to be stored or treated, and corrosion protection so that the tank system will not collapse, rupture, or fail. The ... |
|
Rule 3745-66-93 | Containment and detection of releases- tanks.
...(A) In order to prevent the release of hazardous waste or hazardous constituents to the environment, secondary containment that complies with this rule shall be provided [except as provided in paragraphs (F) and (G) of this rule] for the following: (1) For all new and existing tank systems or components, prior to being put into service. (2) For tank systems that store or treat materials that... |
|
Rule 3745-66-93 | Containment and detection of releases - tanks.
...(A) In order to prevent the release of hazardous waste or hazardous constituents to the environment, secondary containment that complies with this rule shall be provided [except as provided in paragraphs (F) and (G) of this rule] for the following: (1) For all new and existing tank systems or components, prior to being put into service; (2) For tank systems that store or treat materials that... |
|
Rule 3745-66-93 | Containment and detection of releases - tanks.
...(A) In order to prevent the release of hazardous waste or hazardous constituents to the environment, secondary containment that complies with this rule shall be provided [except as provided in paragraphs (F) and (G) of this rule]: (1) For all new and existing tank systems or components, prior to being put into service; and (2) For tank systems that store or treat materials that become hazard... |
|
Rule 3745-66-93 | Containment and detection of releases - tanks.
...(A) In order to prevent the release of hazardous waste or hazardous constituents to the environment, secondary containment that meets the requirements of this rule shall be provided [except as provided in paragraphs (F) and (G) of this rule]: (1) For all new and existing tank systems or components, prior to being put into service; and (2) For tank systems that store or treat materials that b... |
|
Rule 3745-66-95 | Inspections- tank systems.
...(A) The owner or operator shall inspect, where present, at least once each operating day, data gathered from monitoring and leak-detection equipment (e.g., pressure or temperature gauges, monitoring wells) to ensure that the tank system is being operated according to the tank system's design. (B) Except as noted under paragraph (C) of this rule, the owner or operator shall inspect at least once per operating day all... |
|
Rule 3745-66-95 | Inspections- tank systems.
...(A) The owner or operator shall inspect, where present, at least once each operating day, data gathered from monitoring and leak-detection equipment (e.g., pressure or temperature gauges, monitoring wells) to ensure that the tank system is being operated according to the tank system's design. [Comment: Paragraph (C) of rule 3745-65-15 of the Administrative Code requires the owner or operator to r... |
|
Rule 3745-66-96 | Response to leaks or spills and disposition of leaking or unfit for use tank systems.
...A tank system or secondary containment system from which there has been a leak or spill, or which is unfit for use, shall be removed from service immediately, and the owner or operator shall satisfy all of the following requirements: (A) Cessation of use; prevent flow or addition of wastes. The owner or operator shall immediately stop the flow of hazardous waste into the tank system or secondary containment system a... |
|
Rule 3745-66-96 | Response to leaks or spills and disposition of leaking or unfit-for-use tank systems.
...A tank system or secondary containment system from which there has been a leak or spill, or which is unfit for use, shall be removed from service immediately, and the owner or operator shall satisfy all of the following: (A) Cessation of use; prevent flow or addition of wastes. The owner or operator shall immediately stop the flow of hazardous waste into the tank system or secondary containment system ... |
|
Rule 3745-66-96 | Response to leaks or spills and disposition of leaking or unfit-for-use tank systems.
...A tank system or secondary containment system from which there has been a leak or spill, or which is unfit for use, shall be removed from service immediately, and the owner or operator shall satisfy the following requirements: (A) Cessation of use; prevent flow or addition of wastes. The owner or operator shall immediately stop the flow of hazardous waste into the tank system or secondary containment system and insp... |
|
Rule 3745-66-97 | Closure and post-closure care.
...(A) At closure of a tank system, the owner or operator must remove or decontaminate all waste residues, contaminated containment system components (liners, etc.), contaminated soils, and structures and equipment contaminated with waste, and manage them as hazardous waste, unless excluded under provisions contained in paragraph (D) of rule 3745-51-03 of the Administrative Code. The closure plan, closure activities, co... |
|
Rule 3745-67-24 | Response actions- surface impoundments.
...(A) The owner or operator of surface impoundment units subject to paragraph (A) of rule 3745-67-21 of the Administrative Code shall submit a response action plan to the director when submitting the proposed action leakage rate under rule 3745-67-22 of the Administrative Code. The response action plan shall describe the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action... |
|
Rule 3745-67-24 | Response actions- surface impoundments.
...(A) The owner or operator of surface impoundment units subject to paragraph (A) of rule 3745-67-21 of the Administrative Code shall develop a response action plan and keep the response action plan on-site until closure of the facility. The response action plan shall describe the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan shall describe ... |
|
Rule 3745-67-28 | Closure and post closure care.
...(A) At closure, the owner or operator must: (1) Remove or decontaminate all waste residues, contaminated waste containment system components (liners, etc.), contaminated subsoils, and structures and equipment contaminated with waste and leachate, and manage them as hazardous waste unless paragraph (D) of rule 3745-51-03 of the Administrative Code applies; or (2) Close the impoundment and provide post-closure care f... |
|
Rule 3745-67-59 | Response actions- waste piles.
...(A) The owner or operator of waste pile units subject to rule 3745-67-54 of the Administrative Code shall submit a response action plan to the director when submitting the proposed action leakage rate under rule 3745-67-55 of the Administrative Code. The response action plan shall describe the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan shall describe the a... |
|
Rule 3745-67-59 | Response actions- waste piles.
...(A) The owner or operator of waste pile units subject to rule 3745-67-54 of the Administrative Code shall develop a response action plan and keep the response action plan on-site until closure of the facility. The response action plan shall describe the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan shall describe the actions specified in p... |