Ohio Revised Code Search
Section |
---|
Section 4101.12 | Duty of employer to furnish safe place of employment.
...ll fail to furnish, provide, and use safety devices and safeguards, or fail to obey and follow orders or to adopt and use methods and processes reasonably adequate to render such employment and place of employment safe. No employer shall fail to do every other thing reasonably necessary to protect the life, health, safety, and welfare of such employees or frequenters. No such employer or other person shall construct,... |
Section 4101.13 | Duties of employees.
...e, damage, destroy, or carry off any safety device or safeguard furnished or provided for use in any employment or place of employment, or interfere in any way with the use thereof by any other person. No employee shall interfere with the use of any method or process adopted for the protection of any employee in such employment or place of employment, or frequenter of such place of employment, or fail to follow and o... |
Section 4101.14 | Substantial compliance.
...on of a technical nature in respect thereto. |
Section 4101.15 | Prohibited acts.
...No employer, employee, or other person shall violate this chapter or Chapter 4121. of the Revised Code, do any act prohibited by such chapters, fail to perform any duty lawfully enjoined, within the time prescribed by the bureau of workers' compensation, for which violation no penalty has been specifically provided, or fail to obey any lawful order given or made by the bureau, or any judgment or decree made by ... |
Section 4101.16 | Every day a separate violation.
...Every day during which any person, or corporation, or any officer, agent, or employee thereof fails to observe and comply with any order of the bureau of workers' compensation, or to perform any duty enjoined by this chapter and Chapter 4121. of the Revised Code, constitutes a separate violation of the order or chapters. |
Section 4101.99 | Penalty.
... of the Revised Code shall be fined not less than fifty nor more than one thousand dollars for a first offense; for each subsequent offense such person shall be fined not less than one hundred nor more than five thousand dollars. |
Section 4104.01 | Boiler definitions.
...te from processing systems and are complete within themselves. (D) "Power boiler" means a boiler in which steam or other vapor (to be used externally to itself) is generated at a pressure of more than fifteen psig. (E) "High pressure, high temperature water boiler" means a water heating boiler operating at pressures exceeding one hundred sixty psig or temperatures exceeding two hundred fifty degrees Fahrenhei... |
Section 4104.02 | Board of building standards - powers and duties.
...ating the construction and sizes of safety valves for boilers and pressure vessels of different sizes and pressures, for the construction, use, and location of fusible plugs, appliances for indicating the pressure of steam and level of water in the boiler or pressure vessels, and such other appliances as the board considers necessary to safety in operating boilers; (4) Adopt rules that prescribe the conditions... |
Section 4104.03 | Rights of municipal corporations.
...f the installation and inspection of boilers and boiler plants for the purpose of the prevention of the emission of smoke. |
Section 4104.04 | Exemptions - safety devices.
...taining only water under pressure for domestic supply purposes, including those containing air, the compression of which serves only as a cushion or airlift pumping system, when located in private residences or in apartment houses of less than six family units; (5) Portable boilers used in pumping, heating, steaming, and drilling, in the open field, for water, gas, and oil; (6) Portable boilers used in the construc... |
Section 4104.05 | Operation of boilers and stationery steam engines.
...more than three hundred sixty square feet of heating surface, unless one of the following applies to that person: (1) The person is licensed as a steam engineer, high pressure boiler operator, or low pressure boiler operator in accordance with section 4104.19 of the Revised Code. (2) The person is working under the direct supervision of a steam engineer, high pressure boiler operator, or low pressure boiler ... |
Section 4104.06 | Inspectors - rules - right of entry.
... and revocation of certificates of competency and certificates of operation, for conducting hearings in accordance with Chapter 119. of the Revised Code related to these actions, and for the inspection of boilers and their appurtenances, and pressure vessels. (C) Notwithstanding division (B) of this section, the superintendent shall not adopt rules relating to construction, maintenance, or repair of boilers an... |
Section 4104.07 | Inspector of boilers and unfired pressure vessels - application for examination - certification.
...d Code. (B) The superintendent shall determine if an applicant meets all the requirements for examination in accordance with rules adopted by the board of building standards under section 4104.02 of the Revised Code. An application shall be rejected which contains any willful falsification, or untruthful statements. (C) An applicant shall be examined by the superintendent, by a written examination, prescribed by ... |
Section 4104.08 | Director of commerce may appoint general and special inspectors.
... Revised Code, general inspectors of boilers and pressure vessels. (B) Any company authorized to insure boilers and pressure vessels against explosion in this state may designate from holders of certificates of competency issued by the superintendent of industrial compliance, or holders of certificates of competency or commissions issued by other states or nations whose examinations for certificates or commissions... |
Section 4104.09 | Revoking certificate of competency or commission.
...The certificate of competency issued under section 4104.07 of the Revised Code or the commission provided for in section 4104.08 of the Revised Code may be revoked by the superintendent of industrial compliance for the incompetence of the holder thereof, or for willful falsification of any matter or statement contained in the holder's application or in a report of any inspection in accordance with Chapter 119. of the... |
Section 4104.10 | Inspection of unfired pressure vessels.
...ected during fabrication and upon completion and shall not be operated until a copy of the manufacturers' data report, properly executed and signed by the inspector is filed in the office of the superintendent of industrial compliance. All unfired pressure vessels shall conform in every detail with applicable rules adopted by the board of building standards pursuant to section 4104.02 of the Revised Code. |
Section 4104.101 | Registration and permits from division of industrial compliance.
...ajor repairs or modifications to any boiler without first registering to do so with the division of industrial compliance. (B) No person shall make any installation or major repair or modification of any boiler without first obtaining a permit to do so from the division. The permit application form shall provide the name and address of the owner, location of the boiler, and type of repair or modification that will ... |
Section 4104.11 | Inspecting boilers.
...(A) All power boilers and high pressure, high temperature water boilers and their appurtenances shall be thoroughly inspected internally and externally and under operating conditions at intervals of not more than one year, unless approved for biennial inspection under section 4104.13 of the Revised Code, and shall not be operated at pressures in excess of the safe working pressure stated in the certificate of operati... |
Section 4104.12 | Inspecting boiler installation.
...ected during construction and upon completion, by either a general or special inspector, and which does not conform in every detail with the rules adopted by the board of building standards and unless, upon completion, such boiler is distinctly stamped under such rules by such inspector. |
Section 4104.13 | Interval inspection of boilers.
... limiting serious corrosion, and other deteriorating factors shall be thoroughly inspected internally and externally and under operating conditions at intervals of not more than two years and shall not be operated at pressures in excess of the safe working pressure stated in the certificate of operation mentioned in sections 4104.12 and 4104.15 of the Revised Code. Process boilers having internal continuous water tr... |
Section 4104.14 | Preparing boiler for inspection.
...thoroughly cleaning the boiler and its setting. The inspector, when making inspections under operating conditions, shall observe the pressure carried and the general condition of each boiler, and ascertain if the safety valve and the appliances for indicating the pressure and level of water in the boiler are in proper working order. No person shall remove or tamper with any safety appliances prescribed by the board ... |
Section 4104.15 | Certificates of inspection and operation.
...emises and shall be accessible at all times. (C) If an inspector at any inspection finds that the boiler or pressure vessel is not in safe working condition, or is not provided with the fittings necessary to safety, or if the fittings are improperly arranged, the inspector shall immediately notify the owner or user and person in charge of the boiler and shall report the same to the superintendent who may revoke, sus... |
Section 4104.16 | Notifying superintendent of the division of industrial compliance of safety defect or of relocation.
...iance in case a defect affecting the safety of the boiler is discovered. The owner or user of any stationary boiler required by such sections to be inspected, who moves the same, shall report to the superintendent the new location of the boiler. Such boiler shall be inspected before it is again operated. |
Section 4104.17 | Certificates of operation - issuance and renewal.
...Certificates of operation issued for boilers subject to inspection under Chapter 4104. of the Revised Code shall be issued and renewed in accordance with and at dates prescribed by rules and regulations adopted by the superintendent of industrial compliance. |
Section 4104.18 | Fees.
... be paid into the state treasury to the credit of the industrial compliance operating fund created in section 121.084 of the Revised Code. (G) Any person who fails to pay an invoiced renewal fee or an invoiced inspection fee required for any inspection conducted by the division of industrial compliance pursuant to this chapter within forty-five days of the invoice date shall pay a late payment fee equal to twenty-f... |