Rule 3701:1-52-19 | Operating and emergency procedures.
(A) The licensee shall have and follow written operating procedures for:
(1) Operation of the irradiator, including entering and leaving the radiation room;
(2) Use of personnel dosimeters;
(3) Surveying the shielding of panoramic irradiators;
(4) Monitoring pool water for contamination while the water is in the pool and before release of pool water to unrestricted areas;
(5) Leak testing of sources;
(6) Inspection and maintenance checks required by rule 3701:1-52-23 of the Administrative Code;
(7) Loading, unloading, and repositioning sources, if the operations will be performed by the licensee; and
(8) Inspection of movable shielding required by paragraph (H) of rule 3701:1-52-08 of the Administrative Code, if applicable.
(B) The licensee shall have and follow emergency or abnormal event procedures, appropriate for the irradiator type, for:
(1) Sources stuck in the unshielded position;
(2) Personnel overexposures;
(3) A radiation alarm from the product exit portal monitor or pool monitor;
(4) Detection of leaking sources, pool contamination, or alarm caused by contamination of pool water;
(5) A low or high water level indicator, an abnormal water loss, or leakage from the source storage pool;
(6) A prolonged loss of electrical power;
(7) A fire alarm or explosion in the radiation room;
(8) An alarm indicating unauthorized entry into the radiation room, area around pool, or another alarmed area;
(9) Natural phenomena, including an earthquake, a tornado, flooding, or other phenomena as appropriate for the geographical location of the facility; and
(10) The jamming of automatic conveyor systems.
(C) The licensee may revise operating and emergency procedures without director approval only if all of the following conditions are met:
(1) The revisions do not reduce the safety of the facility;
(2) The revisions are consistent with the outline or summary of procedures submitted with the license application;
(3) The revisions have been reviewed and approved by the radiation safety officer; and
(4) The users or operators are instructed and tested on the revised procedures before they are put into use.
Last updated August 1, 2023 at 2:40 PM