Rule 3745-34-59 | Information to be evaluated by the director.
(A) For a new class I hazardous waste injection well, the owner shall submit all information listed in paragraph (B) of this rule as part of the permit application except for those items of information which are current, accurate, and available in the existing permit record. For both existing and new class I hazardous waste injection wells, certain maps, cross-sections, tabulations of wells within the area of review and other data may be included in the application by reference provided they are current and readily available to the director and sufficiently identifiable to be retrieved.
(B) Prior to the issuance of a permit for an existing class I hazardous waste injection well to operate or the construction or conversion of a new class I hazardous waste injection well, the director shall review the following to assure that the requirements of this chapter are met:
(1) Information required by rules 3745-34-12, 3745-34-13, and 3745-34-14 of the Administrative Code.
(2) A map showing the injection well for which a permit is sought and the applicable area of review. Within the area of review, the map shall show the number or name and location of all producing wells, injection wells, abandoned wells, dry holes, surface bodies of water, springs, mines (surface and subsurface), quarries, water wells and other pertinent surface features, including residences and roads. The map should also show faults, if known or suspected.
(3) A tabulation of all wells within the area of review which penetrate the proposed injection zone or confining zone. Such data shall include a description of each well's type, construction, date drilled, location, depth, record of plugging and/or completion and any additional information the director may require.
(4) The protocol followed to identify, locate and ascertain the condition of abandoned wells within the area of review which penetrate the injection or the confining zones.
(5) Maps and cross-sections indicating the general vertical and lateral limits of all underground sources of drinking water within the area of review, their position relative to the injection formation and the direction of water movement, where known, in each underground source of drinking water which may be affected by the proposed injection.
(6) Maps and cross-sections detailing the geologic structure of the local area.
(7) Maps and cross-sections illustrating the regional geologic setting.
(8) Proposed operating data:
(a) Average and maximum daily rate and volume of the fluid to be injected.
(b) Average and maximum injection pressure and calculation of proposed maximum injection pressure.
(9) Proposed formation testing program to obtain an analysis of the chemical, physical and radiological characteristics of and other information on the injection formation and the confining zone.
(10) Proposed stimulation program.
(11) Proposed injection procedure.
(12) Schematic or other appropriate drawings of the surface and subsurface construction details of the well.
(13) Contingency plans to cope with all shut-ins or well failures so as to prevent migration of fluids into any USDW.
(14) Plans (including maps) for meeting monitoring requirements of rule 3745-34-57 of the Administrative Code.
(15) For wells within the area of review which penetrate the injection zone or the confining zone but are not properly completed or plugged, the plan and comprehensive schedule for corrective action to be taken under rule 3745-34-53 of the Administrative Code.
(16) Construction procedures including a cementing and casing program, well materials specifications and their life expectancy, logging procedures, deviation checks, and a drilling, testing and coring program.
(17) A certificate that the applicant has assured, through a performance bond or other appropriate means, the resources necessary to close, plug or abandon the well and for post closure care.
(C) Prior to the director's granting approval for the operation of a Class I hazardous waste injection well, the owner shall submit to the director for review the following information, which shall be included in the completion report:
(1) All available logging and testing program data on the well.
(2) A demonstration of mechanical integrity pursuant to rule 3745-34-58 of the Administrative Code.
(3) The anticipated maximum pressure and flow rate at which the permittee will operate.
(4) The results of the injection zone and confining zone testing program as required in rule 3745-34-60 of the Administrative Code.
(5) The actual injection procedure.
(6) The compatibility of injected waste with fluids in the injection zone and minerals in both the injection zone and confining zone and with materials used to construct the well.
(7) The calculated area of review based on data obtained during logging and testing of the well and the formation, and where necessary revisions to the information submitted under rule 3745-34-60 of the Administrative Code.
(8) The status of corrective action on wells identified in rule 3745-34-60 of the Administrative Code.
(D) Prior to granting approval for the plugging and abandonment or closure of a Class I hazardous waste injection well, the director shall review the information required by rules 3745-34-61 and 3745-34-62 of the Administrative Code.
(E) Any permit issued for a Class I hazardous waste injection well for disposal on the premises where the waste is generated shall contain a certification by the owner or operator that:
(1) The generator of the hazardous waste has a program to reduce the volume or quantity and toxicity of such waste to the degree determined by the generator to be economically practicable.
(2) Injection of the waste is that practicable method of disposal currently available to the generator which minimizes the present and future threat to human health and the environment.
Last updated December 12, 2024 at 8:10 AM