Ohio Administrative Code Search
| Rule |
|---|
|
Rule 3745-535-600 | General operations.
... operator shall ensure the following: (1) An individual meeting the definition of operator is thoroughly familiar with the proper operational procedures, license, permits, and other authorizations pertaining to the facility. (2) The working face is supervised by a person or persons knowledgeable regarding operations at the working face. (B) The owner or operator shall conduct operations at the ... |
|
Rule 3745-535-610 | Waste acceptance and placement.
...zations related to the following: (1) Leachate treatment and disposal. (2) Discharges to surface water. (3) Management of surface water runoff. (4) Air emissions. (B) The owner or operator shall not begin filling in a new phase until the following have occurred: (1) The approved limits of waste placement in the previous phase have been reached, except to the extent necessary for ... |
|
Rule 3745-535-620 | Disposal restrictions.
...se of any of the following materials: (1) Asbestos or asbestos-containing waste material that is subject to the provisions of 40 C.F.R. Part 61, subpart M (1984), without the necessary permits. (2) Containerized bulk liquids or non-containerized liquids. For the purposes of this rule, bulk liquid containers do not include small containers that are of a size normally found in household waste. (3... |
|
Rule 3745-535-630 | Daily, intermediate, and final cover.
... vectors, and rodents as follows: (1) Except for solid waste approved as alternative daily cover in accordance with paragraph (A)(3)(c) of this rule, ensure solid waste is not exposed for more than twenty-four hours after unloading. (2) Apply only cover material that is nonputrescible, does not contain large objects in such quantities as may interfere with its application and intended purpos... |
|
Rule 3745-535-660 | Annual report.
...perator shall identify the following: (1) The calendar year that the submittal represents. (2) The areal extent of each phase of construction. (3) The areal extent of closed areas of all units that have a final cap system or have transitional cover. (4) Areas that have intermediate cover. (5) The current working phase and unit. (6) The projected phase and unit for filling in the coming y... |
|
Rule 3745-535-800 | General groundwater monitoring requirements.
...ative Code are applicable as follows: (1) To the owner or operator of a solid waste landfill subject to rule 3745-27-14 of the Administrative Code who ceased waste acceptance after March 1, 1990, unless on the effective date of this rule, the owner or operator is in post-closure care and conducting groundwater monitoring pursuant to a past version of rule 3745-27-10 of the Administrative Code under an existing order... |
|
Rule 3745-535-801 | Detection monitoring parameter list.
...lene (CAS RN 96-47-6), m-xylene (CAS RN 108- 38-3), p-xylene (CAS RN 106-42-3), and unspecified xylenes (dimethylbenzenes) (CAS RN 1330-20-7). Compound: CAS RN: 1) Antimony 7440-36-0 2) Arsenic 7440-38-2 3) Barium 7440-39-3 4) Beryllium 7440-41-7 5) Cadmium 7440-43-9 6) Chromium 7440-47-3 7) Cobalt 7440-48-4 8) Copper 7440-50-8 9) Lead 7439-92-1 10) Nickel 7440-02-0 11)... |
|
Rule 3745-535-802 | Assessment monitoring parameter list.
...ical name have the following meaning: (1) "a" means small case "a." (2) "A" means alpha. (3) "b" means small case "b." (4) "B" means beta. (D) CAS No. 108-60-1. This substance is often called bis(2-Chloroisopropyl) ether, the name chemical abstracts service applies to its commercial isomer, propane, 2, 2" -oxybis [2-Chloro- CAS RN 39638-32-9). (E) Chlordane includes alpha-chlordane (CAS RN 5103-71-9), beta-Chlo... |
|
Rule 3745-535-805 | Groundwater monitoring system.
...samples that represent the following: (1) The background groundwater quality that has not been affected by past or present operations at the solid waste landfill. (2) The groundwater quality passing directly downgradient of the limits of solid waste placement. (B) The director may order or otherwise authorize an owner or operator to conduct surface water monitoring as part of the groundwater monitoring system in a... |
|
Rule 3745-535-820 | Groundwater detection monitoring.
...nimum a description of the following: (1) A groundwater monitoring system in accordance with rule 3475-535-805 of the Administrative Code. (2) Sampling and analysis procedures, including an appropriate statistical method, in accordance with rules 3745-535-810 and 3745-535-815 of the Administrative Code. (3) Detection monitoring procedures, including monitoring frequency and a parameter list, in accordance with par... |
|
Rule 3745-535-825 | Groundwater detection monitoring alternative monitoring parameters and frequency.
...parameters contained in rule 3745-535-801 of the Administrative Code if the removed parameters are not reasonably expected to be in or derived from the waste contained or deposited in the facility. The owner or operator shall at a minimum include the following in the request for an alternative parameter list: (1) The parameters proposed for deletion in rule 3745-535-801 of the Administrative Code. (2) The types, q... |
|
Rule 3745-535-830 | Groundwater quality assessment monitoring program.
...ment plan to the director as follows: (1) Not later than one hundred eighty days after withdrawing a groundwater sample from the monitoring well that upon analysis demonstrates a statistically significant increase above background. (2) Not later than ninety days after notification by the director that the report submitted under paragraph (D) of rule 3745-535-820 of the Administrative Code does not successfully make... |
|
Rule 3745-535-840 | Compliance monitoring program.
...or demonstrates one of the following: (1) A release of constituents to groundwater has occurred pursuant to paragraph (G) of rule 3745-535-830 of the Administrative Code and the concentrations of all waste-derived constituents are above background values but below the groundwater remediation standards. (2) The concentrations of all waste-derived constituents are below groundwater remediation standards in the monito... |
|
Rule 3745-535-850 | Corrective measures general requirements.
... and at a minimum does the following: (1) Is protective of human health and safety and the environment. (2) Attains the proposed groundwater concentration levels specified in rule 3745-535-860 of the Administrative Code. (3) Controls the source of the releases to reduce or eliminate, to the maximum extent practicable, further releases of waste-derived constituents into the environment. (4) Complies with standards... |
|
Rule 3745-535-855 | Corrective measures implementation and completion.
...r or operator shall do the following: (1) Implement the selected remedy as specified in paragraph (H) of rule 3745-535-850 of the Administrative Code. (2) Implement the corrective measures monitoring program in accordance with paragraph (B)(5) of rule 3745-535-850 of the Administrative Code. (3) If, at any time during the implementation of the remedy, the director determines that the facility threatens human healt... |
|
Rule 3745-535-860 | Groundwater remediation standards.
...f the Administrative Code as follows: (1) For constituents with a maximum contaminant level specified in Chapter 3745-81 of the Administrative Code, the maximum contaminant level for that constituent. (2) For constituents without a maximum contaminant level specified in Chapter 3745-81 of the Administrative Code, the background concentration for the constituent well established in accordance with paragraphs (D) and... |
|
Rule 3745-550-300 | Permit to install.
...tains at a minimum the following: (1) Plan sheets in accordance with paragraph (D) of this rule and a narrative report in accordance with paragraph (E) of this rule. Detail engineering plans, specifications, and information as specified in this rule shall be sufficiently detailed to allow for technical review of the permit application and to provide assurance that the facility is designed and... |
|
Rule 3745-550-300 | Permit to install.
... contains at a minimum the following: (1) Plan sheets in accordance with paragraph (D) of this rule and a narrative report in accordance with paragraph (E) of this rule. Detail engineering plans, specifications, and information as specified in this rule shall be sufficiently detailed to allow for technical review of the permit application and to provide assurance that the facility is designed and... |
|
Rule 3745-550-350 | Permit to install issuance.
...e procedures set forth in rule 3745-500-120 of the Administrative Code, Chapter 3745-49 of the Administrative Code, and section 3734.09 of the Revised Code. The director shall not approve any permit to install application for a facility unless the director determines the following: (1) The owner or operator is capable of operating the facility in compliance with Chapters 3704., 3734., 3745., and ... |
|
Rule 3745-550-600 | Operations.
...ired by Chapters 3704., 3734., and 6111. of the Revised Code and the rules adopted thereunder. The owner or operator shall make copies of the approved detail plans, specifications, and information as specified in paragraph (D) of rule 3745-550-300 of the Administrative Code available for inspection by the board of health or the director upon request. (B) The owner or operator of a facility sh... |
|
Rule 3745-550-700 | Closure.
...le if any of the following occur: (1) The facility ceases solid waste acceptance. (2) A facility license held by the owner or operator of the facility expires and no license renewal has been applied for in the manner prescribed in Chapter 3745-501 of the Administrative Code. (3) A facility license held by the owner or operator of the facility expires and a license renewal has been appli... |
|
Rule 3745-555-150 | Surface waters.
... of the state as defined in rule 3745-1-02 of the Administrative Code in existence on the date Ohio EPA receives the permit to install application. |
|
Rule 3745-555-300 | Permit to install application procedures.
... information required in rule 3745-555-310 of the Administrative Code such that the director can determine if the criteria set forth in rule 3745-555-320 of the Administrative Code are satisfied. (B) An application for a permit to install shall be accompanied by the application fee prescribed in division (A)(2)(c) of section 3734.05 of the Revised Code. (C) For regulatory review purposes, the ... |
|
Rule 3745-555-300 | Permit to install application procedures.
... information required in rule 3745-555-310 of the Administrative Code such that the director can determine if the criteria set forth in rule 3745-555-320 of the Administrative Code are satisfied. (B) An application for a permit to install shall be accompanied by the application fee prescribed in division (A)(2)(c) of section 3734.05 of the Revised Code. (C) For regulatory review purposes, the ... |
|
Rule 3745-555-310 | Transfer facility permit to install application.
...four inches by thirty-six inches. (1) The detail engineering plan cover sheet, to be numbered sheet 1, shall contain the following information: (a) The name of the transfer facility. (b) The precise geographic location and boundary of the transfer facility, to be shown on a road map. (c) The name, address, and telephone number of the applicant. (d) The name and address of the owner and operat... |