Ohio Administrative Code Search
| Rule |
|---|
|
Rule 3701:1-46-43 | Manufacture, preparation, or transfer for commercial distribution of radioactive drugs containing radioactive material for medical use.
...(A) An application for a specific license to manufacture, prepare, or transfer for commercial distribution radioactive drugs containing radioactive material for use by persons authorized pursuant to Chapter 3701:1-58 of the Administrative Code or equivalent regulations of an agreement state will be approved if: (1) The applicant satisfies the general requirements specified in rule 3701:1-40-15 of the Administrative ... |
|
Rule 3701:1-46-43 | Manufacture, preparation, or transfer for commercial distribution of radioactive drugs containing radioactive material for medical use.
...(A) An application for a specific license to manufacture, prepare, or transfer for commercial distribution radioactive drugs containing radioactive material for use by persons authorized pursuant to Chapter 3701:1-58 of the Administrative Code or equivalent regulations of an agreement state will be approved if: (1) The applicant satisfies the general requirements specified in rule 3701:1-40-15 of the Administrative ... |
|
Rule 3701:1-48-16 | Training.
...(A) The licensee may not permit any individual to act as a radiographer until the individual: Has received training in the subjects in paragraph (G) of this rule, in addition to a minimum of two months of on-the-job training, is certified through a radiographer certification program by a certifying entity in accordance with the criteria specified in appendix A to this rule and is approved by the director. (B) In ad... |
|
Rule 3701:1-49-07 | Leak testing of sealed sources.
...(A) Each licensee who uses a sealed source shall have the source tested for leakage. The licensee shall keep a record of leak test results in units of microcuries and retain the record for inspection by the director for three years after the leak test is performed. (B) The wipe of a sealed source must be performed using a leak test kit or method approved by the director, the United States nuclear regulatory commissi... |
|
Rule 3701:1-49-15 | Use of a sealed source in a well without a surface casing.
...The licensee may use a sealed source in a well without a surface casing for protecting fresh water aquifers only if the licensee follows a procedure for reducing the probability of the source becoming lodged in the well. The procedure must be approved by the director pursuant to paragraph (B)(3) of rule 3701:1-49-03 of the Administrative Code, the United States nuclear regulatory commission or an agreement state. |
|
Rule 3701:1-50-06 | Exemption for low-level materials.
...(A) A licensee is exempt from all the requirements of this chapter with respect to shipment or carriage of the following low-level materials: (1) Natural material and ores containing naturally occurring radionuclides that are either in their natural state, or have only been processed for purposes other than for the extraction of the radionuclides, and which are not intended to be processed for th... |
|
Rule 3701:1-50-23 | Advance notification of shipment of irradiated reactor fuel and nuclear waste.
...(A) (1) As specified in paragraphs (B), (C) and (D) of this rule, each licensee shall provide advance notification to the governor of a state, or the governor's designee, of the shipment of licensed material, through, or across the boundary of the state, before the transport, or delivery to a carrier, for transport, of licensed material outside the confines of the licensee's plant or other ... |
|
Rule 3701:1-50-23 | Advance notification of shipment of irradiated reactor fuel and nuclear waste.
...(A) (1) As specified in paragraphs (B), (C) and (D) of this rule, each licensee shall provide advance notification to the governor of a state, or the governor's designee, of the shipment of licensed material, through, or across the boundary of the state, before the transport, or delivery to a carrier, for transport, of licensed material outside the confines of the licensee's plant or other ... |
|
Rule 3701:1-50-25 | Determination of A1 and A2 values for radionuclides.
... |
|
Rule 3701:1-50-25 | Determination of A[1] and A[2] values for radionuclides.
... |
|
Rule 3701:1-52-20 | Personnel monitoring.
...(A) Irradiator operators shall wear a personnel dosimeter that is processed and evaluated by an accredited national voluntary laboratory accreditation program (NVLAP) processor while operating a panoramic irradiator or while in the area around the pool of an underwater irradiator. The personnel dosimeter processor must be accredited for high energy photons in the normal and accident dose ranges as indicated in paragr... |
|
Rule 3701:1-52-28 | Records and retention periods.
...The licensee shall maintain the following records at the irradiator for the periods specified. (A) A copy of the license, license conditions, documents incorporated into a license by reference, and amendments thereto until superseded by new documents or until the director terminates the license. (B) Records of each individual's training, tests, and safety reviews provided to meet the requirements of paragraphs (A),... |
|
Rule 3701:1-54-03 | Assured isolation facility.
...(A) This rule covers the licensing of the storage and safe isolation of licensable radioactive waste, and not disposal of such waste as delineated in rules 3701:1-54-06 to 3701:1-54-12 of the Administrative Code, over the term of a license prior to disposal in accordance with Chapter 3701:1-38 of the Administrative Code, and other rules promulgated under Chapter 3748. of the Revised Code. The requirements of this rul... |
|
Rule 3701:1-54-03 | Assured isolation facility.
...(A) This rule covers the licensing of the storage and safe isolation of licensable radioactive waste, and not disposal of such waste as delineated in rules 3701:1-54-06 to 3701:1-54-12 of the Administrative Code, over the term of a license prior to disposal in accordance with Chapter 3701:1-38 of the Administrative Code, and other rules promulgated under Chapter 3748. of the Revised Code. The requ... |
|
Rule 3701:1-54-07 | Land disposal - license.
...(A) No person shall receive, possess or dispose of radioactive waste received from another licensee at a land disposal facility unless authorized by a license issued by the department pursuant to this rule. Each person shall file an application with the department in accordance with the procedural requirements of Chapter 3701:1-40 of the Administrative Code as if those rules also included source, and special nuclear ... |
|
Rule 3701:1-54-10 | Land disposal - waste classifications and characteristics.
...(A) The criteria to use for classifying waste for disposal are recorded below. (1) Determination of the classification of radioactive waste involves two considerations. First, consideration must be given to the concentration of long-lived radionuclides (and their shorter-lived precursors) whose potential hazard will persist long after such precautions as institutional controls and improved waste form have ceased to ... |
|
Rule 3701:1-54-10 | Land disposal - waste classifications and characteristics.
...(A) The criteria to use for classifying waste for disposal are recorded below. (1) Determination of the classification of radioactive waste involves two considerations. First, consideration must be given to the concentration of long-lived radionuclides (and their shorter-lived precursors) whose potential hazard will persist long after such precautions as institutional controls and improved waste form have ceased to ... |
|
Rule 3701:1-58-41 | Training for the oral administration of sodium iodide iodine-131 requiring a written directive in quantities less than or equal to 1.22 gigabecquerels (thirty-three millicuries).
...Except as provided in rule 3701:1-58-21 of the Administrative Code, the licensee shall require an authorized user for the oral administration of sodium iodide iodine-131 requiring a written directive in quantities less than or equal to 1.22 gigabecquerels (thirty-three millicuries) to be a physician who: (A) Is certified by a medical specialty board whose certification process includes all of the requirements in par... |
|
Rule 3701:1-58-42 | Training for the oral administration of sodium iodide iodine-131 requiring a written directive in quantities greater than 1.22 gigabecquerels (thirty-three millicuries).
...Except as provided in rule 3701:1-58-21 of the Administrative Code, the licensee shall require an authorized user for the oral administration of sodium iodide iodine-131 requiring a written directive in quantities greater than 1.22 gigabecquerels (thirty-three millicuries) to be a physician who: (A) Is certified by a medical specialty board whose certification process includes all of the requirements in paragraphs (... |
|
Rule 3701:1-58-51 | Training for use of manual brachytherapy sources.
...Except as provided in rule 3701:1-58-21 of the Administrative Code, the licensee shall require an authorized user of a manual brachytherapy source for the uses authorized under rule 3701:1-58-43 of the Administrative Code to be a physician who: (A) Is certified by a medical specialty board whose certification process has been recognized by the director, United States nuclear regulatory commission, or an agreement st... |
|
Rule 3701:1-58-66 | Periodic spot-checks for gamma stereotactic radiosurgery units.
...(A) A licensee authorized to use a gamma stereotactic radiosurgery unit for medical use shall perform spot-checks of each gamma stereotactic radiosurgery facility and on each unit: (1) Monthly; (2) Before the first use of the unit on a given day; and (3) After each source installation. (B) A licensee shall: (1) Perform the measurements required by paragraph (A) of this rule in accordance with written procedures ... |
|
Rule 3701:1-58-71 | Training for use of remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units.
...Except as provided in rule 3701:1-58-21 of the Administrative Code, the licensee shall require an authorized user of a sealed source for a use authorized under rule 3701:1-58-55 of the Administrative Code to be a physician who: (A) Is certified by a medical specialty board whose certification process has been recognized by the director, United States nuclear regulatory commission, or an agreement state and who meets... |
|
Rule 3701:1-58-104 | Training for the parenteral administration of unsealed radioactive material requiring a written directive.
...(A) Except as provided in rule 3701:1-58-21 of the Administrative Code, the licensee shall require an authorized user for the parenteral administration of unsealed radioactive material requiring a written directive, to be a physician who: (1) Is an authorized user under rule 3701:1-58-40 of the Administrative Code for uses listed in paragraph (B)(1)(b)(vi)(c) or (B)(1)(b)(vi)(d) of rule 3701:1-58-40 of the Administr... |
|
Rule 3701:1-66-01 | Definitions.
...(A) As used in this chapter: (1) "Air kerma" means the sum of the initial kinetic energy of all charged ionizing particles liberated by uncharged ionizing radiation in a given mass of air. The unit for air kerma is joules per kilogram which is given the special name of gray (Gy). To determine air kerma in Gy from exposure in units of roentgens (R) multiply exposure by the conversion factor 0.0087... |
|
Rule 3701:1-66-01 | Definitions.
...(A) As used in this chapter: (1) "Air kerma" means the sum of the initial kinetic energy of all charged ionizing particles liberated by uncharged ionizing radiation in a given mass of air. The unit for air kerma is joules per kilogram which is given the special name of gray (Gy). To determine air kerma in Gy from exposure in units of roentgens (R) multiply exposure by the conversion factor 0.00876 Gy/R. (2) "Air ke... |