Ohio Administrative Code Search
| Rule |
|---|
|
Rule 3745-205-86 | Containers - air emission standards for tanks, surface impoundments, and containers.
...(A) This rule applies to the control of air pollutant emissions from containers for which paragraph (B) of rule 3745-205-82 of the Administrative Code references the use of this rule for such air emission control. (B) General requirements. (1) The owner or operator shall control air pollutant emissions from each container subject to this rule in accordance with the following requirements, as app... |
|
Rule 3745-205-86 | Containers - air emission standards for tanks, surface impoundments, and containers.
...(A) The provisions of this rule apply to the control of air pollutant emissions from containers for which paragraph (B) of rule 3745-205-82 of the Administrative Code references the use of this rule for such air emission control. (B) General requirements. (1) The owner or operator shall control air pollutant emissions from each container subject to this rule in accordance with the following requirements, as applica... |
|
Rule 3745-205-87 | Closed-vent systems and control devices - air emission standards for tanks, surface impoundments, and containers.
...(A) This rule applies to each closed-vent system and control device installed and operated by the owner or operator to control air emissions in accordance with standards of rules 3745-205-80 to 3745-205-90 of the Administrative Code. (B) The closed-vent system shall meet the following requirements: (1) The closed-vent system shall route the gases, vapors, and fumes emitted from the hazardous ... |
|
Rule 3745-205-87 | Closed-vent systems and control devices - air emission standards for tanks, surface impoundments, and containers.
...(A) This rule applies to each closed-vent system and control device installed and operated by the owner or operator to control air emissions in accordance with standards of rules 3745-205-80 to 3745-205-90 of the Administrative Code. (B) The closed-vent system shall meet the following requirements: (1) The closed-vent system shall route the gases, vapors, and fumes emitted from the hazardous ... |
|
Rule 3745-205-89 | Recordkeeping - air emission standards for tanks, surface impoundments, and containers.
...(A) Each owner or operator of a facility subject to requirements of rules 3745-205-80 to 3745-205-90 of the Administrative Code shall record and maintain the information specified in paragraphs (B) to (J) of this rule, as applicable to the facility. Except for air emission control equipment design documentation and information required by paragraphs (I) and (J) of this rule, records required by th... |
|
Rule 3745-205-101 | Design and operating standards for containment buildings.
...(A) All containment buildings shall comply with the following design standards: (1) The containment buildings shall be completely enclosed with a floor, walls, and a roof to prevent exposure to the elements (e.g., precipitation, wind, run-on), and to assure containment of managed wastes. (2) The floor and containment walls of the unit, including the secondary containment system if required under paragraph (B) of th... |
|
Rule 3745-205-101 | Design and operating standards for containment buildings.
...(A) All containment buildings shall comply with the following design standards: (1) The containment buildings shall be completely enclosed with a floor, walls, and a roof to prevent exposure to the elements (e.g., precipitation, wind, run-on), and to assure containment of managed wastes. (2) The floor and containment walls of the unit, including the secondary containment system if required u... |
|
Rule 3745-256-33 | Closed-vent systems and control devices - process vents.
...(A) (1) Owners or operators of closed-vent systems and control devices used to comply with rules 3745-256-30 to 3745-256-35 of the Administrative Code shall comply with this rule. (2) (a) The owner or operator of an existing facility who cannot install a closed-vent system and control device to comply with rules 3745-256-30 to 3745-256-35 of the Administrative Code on the effective date t... |
|
Rule 3745-256-33 | Closed-vent systems and control devices - process vents.
...(A) (1) Owners or operators of closed-vent systems and control devices used to comply with rules 3745-256-30 to 3745-256-35 of the Administrative Code shall comply with this rule. (2) (a) The owner or operator of an existing facility who cannot install a closed-vent system and control device to comply with rules 3745-256-30 to 3745-256-35 of the Administrative Code on the effective date that the facility becomes... |
|
Rule 3745-256-35 | Recordkeeping - process vents.
...(A) (1) Each owner or operator subject to rules 3745-256-30 to 3745-256-35 of the Administrative Code shall comply with the recordkeeping requirements of this rule. (2) An owner or operator of more than one hazardous waste management unit subject to rules 3745-256-30 to 3745-256-35 of the Administrative Code may comply with the recordkeeping requirements for these hazardous waste management un... |
|
Rule 3745-256-52 | Pumps in light liquid service - equipment leaks.
...(A) (1) Each pump in light liquid service shall be monitored monthly to detect leaks by the methods specified in paragraph (B) of rule 3745-256-63 of the Administrative Code, except as provided in paragraphs (D), (E), and (F) of this rule. (2) Each pump in light liquid service shall be checked by visual inspection each calendar week for indications of liquids dripping from the pump seal. (B) ... |
|
Rule 3745-256-60 | Closed-vent systems and control devices - equipment leaks.
...(A) Owners and operators of closed-vent systems and control devices subject to rules 3745-256-50 to 3745-256-64 of the Administrative Code shall comply with rule 3745-256-33 of the Administrative Code. (B) (1) The owner or operator of an existing facility who cannot install a closed-vent system and control device to comply with rules 3745-256-50 to 3745-256-64 of the Administrative Code on... |
|
Rule 3745-256-62 | Alternate standards for valves in gas or vapor service or in light liquid service; skip period leak detection and repair - equipment leaks.
...(A) An owner or operator subject to the requirements of rule 3745-256-57 of the Administrative Code may elect for all valves within a hazardous waste management unit to comply with one of the alternative work practices specified in paragraphs (B)(2) and (B)(3) of this rule. (B) (1) An owner or operator shall comply with the requirements for valves, as described in rule 3745-256-57 of the A... |
|
Rule 3745-256-64 | Recordkeeping - equipment leaks.
...(A) (1) Each owner or operator subject to rules 3745-256-50 to 3745-256-64 of the Administrative Code shall comply with the recordkeeping requirements of this rule. (2) An owner or operator of more than one hazardous waste management unit subject to rules 3745-256-50 to 3745-256-64 of the Administrative Code may comply with the recordkeeping requirements for these hazardous waste management un... |
|
Rule 3745-256-84 | Waste determination procedures - tanks, surface impoundments, and containers.
...(A) Waste determination procedure to determine average volatile organic (VO) concentration of a hazardous waste at the point of waste origination. (1) An owner or operator shall determine the average VO concentration at the point of waste origination for each hazardous waste placed in a waste management unit exempted under paragraph (C)(1) of rule 3745-256-83 of the Administrative Code from using air emission contro... |
|
Rule 3745-256-85 | Tanks - air emission standards for tanks, surface impoundments, and containers.
...(A) Rules 3745-256-80 to 3745-256-90 of the Administrative Code apply to the control of air pollutant emissions from tanks for which paragraph (B) of rule 3745-256-83 of the Administrative Code references the use of this rule for such air emission control. (B) The owner or operator shall control air pollutant emissions from each tank subject to this rule in accordance with the following requireme... |
|
Rule 3745-256-86 | Surface impoundments - air emission standards for tanks, surface impoundments, and containers.
...(A) This rule applies to the control of air pollutant emissions from surface impoundments for which paragraph (B) of rule 3745-256-83 of the Administrative Code references the use of this rule for such air emission control. (B) The owner or operator shall control air pollutant emissions from the surface impoundment by installing and operating either of the following: (1) A floating membrane ... |
|
Rule 3745-256-87 | Containers - tanks, surface impoundments, and containers.
...(A) This rule applies to the control of air pollutant emissions from containers for which paragraph (B) of rule 3745-256-83 of the Administrative Code references the use of this rule for such air emission control. (B) General requirements. (1) The owner or operator shall control air pollutant emissions from each container subject to this rule in accordance with the following requirements, as app... |
|
Rule 3745-256-87 | Containers - tanks, surface impoundments, and containers.
...(A) The provisions of this rule apply to the control of air pollutant emissions from containers for which paragraph (B) of rule 3745-256-83 of the Administrative Code references the use of this rule for such air emission control. (B) General requirements. (1) The owner or operator shall control air pollutant emissions from each container subject to this rule in accordance with the following requirements, as applica... |
|
Rule 3745-256-88 | Closed-vent systems and control devices - tanks, surface impoundments, and containers.
...(A) This rule applies to each closed-vent system and control device installed and operated by the owner or operator to control air emissions in accordance with standards of rules 3745-256-80 to 3745-256-90 of the Administrative Code. (B) The closed-vent system shall meet the following requirements: (1) The closed-vent system shall route the gases, vapors, and fumes emitted from the hazardous ... |
|
Rule 3745-256-88 | Closed-vent systems and control devices - tanks, surface impoundments, and containers.
...(A) This rule applies to each closed-vent system and control device installed and operated by the owner or operator to control air emissions in accordance with standards of rules 3745-256-80 to 3745-256-90 of the Administrative Code. (B) The closed-vent system shall meet the following requirements: (1) The closed-vent system shall route the gases, vapors, and fumes emitted from the hazardous ... |
|
Rule 3745-256-90 | Recordkeeping - tanks, surface impoundments, and containers.
...(A) Each owner or operator of a facility subject to requirements in rules 3745-256-80 to 3745-256-90 of the Administrative Code shall record and maintain the information specified in paragraphs (B) to (J) of this rule, as applicable to the facility. Except for air emission control equipment design documentation and information required by paragraphs (I) and (J) of this rule, records required by th... |
|
Rule 3745-256-101 | Design and operating standards for containment buildings.
...(A) All containment buildings shall comply with all of the following design standards: (1) The containment building shall be completely enclosed with a floor, walls, and a roof to prevent exposure to the elements, (e.g., precipitation, wind, run-on), and to assure containment of managed wastes. (2) The floor and containment walls of the unit, including the secondary containment system if required under paragraph (B... |
|
Rule 3745-256-101 | Design and operating standards for containment buildings.
...(A) All containment buildings shall comply with all of the following design standards: (1) The containment building shall be completely enclosed with a floor, walls, and a roof to prevent exposure to the elements, (e.g., precipitation, wind, run-on), and to assure containment of managed wastes. (2) The floor and containment walls of the unit, including the secondary containment system if req... |
|
Rule 3745-266-80 | Applicability and requirements- spent lead-acid batteries being reclaimed.
...(A) Are spent lead-acid batteries exempt from hazardous waste management requirements? If you generate, collect, transport, store, or regenerate lead-acid batteries for reclamation purposes, you may be exempt from certain hazardous waste management requirements. Use the following table to determine which requirements apply to you. Alternatively, you may choose to manage your spent lead-acid batteries under Chapter 37... |