Skip to main content
The Legislative Service Commission staff updates the Revised Code on an ongoing basis, as it completes its act review of enacted legislation. Updates may be slower during some times of the year, depending on the volume of enacted legislation.

Ohio Revised Code Search

Titles
Busy
 
Keywords
:
credit fc Visitez le site Buyfc26coins.com Assistance rapide et efficace pour mes FC 26 coins.dUZ5
{"removedFilters":"","searchUpdateUrl":"\/ohio-revised-code\/search\/update-search","keywords":"credit+fc+Visitez+le+site+Buyfc26coins.com++Assistance+rapide+et+efficace+pour+mes+FC+26+coins.dUZ5","start":8801,"pageSize":25,"sort":"BestMatch","title":""}
Results 8,801 - 8,825 of 13,160
Sort Options
Sort Options
Sort Options
Sections
Section
Section 4104.41 | Power or process piping definitions.

... systems, and that may be installed in petroleum refineries, chemical, pharmaceutical, textile, paper, semiconductor, and cryogenic plants, and related processing plants and terminals.

Section 4104.42 | Owner to ensure compliance with pressure piping standards.

... piping, published by the American society of mechanical engineers: (1) The design, fabrication, assembly, installation, testing, examination, and inspection of power and process piping systems; (2) Qualification of personnel and qualification of welding and brazing procedures; (3) The implementation of an inspection program. (B) The owner of a power piping or process piping system shall do both of the follo...

Section 4104.43 | Board of building standards to adopt requirements for building services piping.

...rd of building standards shall adopt rules establishing requirements for the design, installation, inspection of and design review procedure for building services piping. (2) The board of building standards shall adopt rules establishing requirements for the design, installation, inspection of and design review procedure for nonflammable medical gas, medical oxygen, and medical vacuum piping systems. (B) A m...

Section 4104.44 | Welding and brazing to conform to industry standards.

.... The owner shall maintain, at the job site, the certified performance qualification records of all welders and brazers employed at the facility. The owner shall submit copies of all certified welding and brazing procedure specifications, procedure qualification records, and performance qualification records for building services piping for review to the superintendent of industrial compliance in the department...

Section 4104.45 | Inspectors or testing witnesses to be certified.

... witnesses the testing of any nonflammable medical gas and vacuum piping system shall be certified to do so pursuant to division (E) of section 3781.10 of the Revised Code.

Section 4104.46 | Design, installation, and testing of nonflammable medical gas and vacuum piping systems.

...btain certification by the American society of sanitary engineers in accordance with the American society of sanitary engineering series 6000 requirements.

Section 4104.48 | Prohibitions.

...(A) No person shall violate sections 4104.41 to 4104.48 of the Revised Code, fail to perform any duty lawfully enjoined in connection with those sections, or fail to comply with any order issued by the superintendent of industrial compliance or any judgment or decree issued by any court in connection with the enforcement of sections 4104.41 to 4104.48 of the Revised Code. (B) Every day during which a person vi...

Section 4104.99 | Penalty.

...(A) Whoever violates division (A) or (B) of section 4104.101 or section 4104.20 of the Revised Code is guilty of a misdemeanor of the third degree. (B) Whoever violates section 4104.05 of the Revised Code is guilty of a minor misdemeanor.

Section 4105.01 | Definitions.

...r, cage, or platform which moves on or between permanent rails or guides and serves two or more fixed landings in a building or structure to which section 3781.06 of the Revised Code applies or in a private residence. "Elevator" includes dumb-waiters other than hand-powered dumb-waiters, escalators, manlifts, moving walks, of the endless belt type, other lifting or lowering apparatus permanently installed on or betwe...

Section 4105.011 | Board of building standards - powers and duties.

... protection of the public health and safety and shall follow generally accepted engineering standards, formulae, and practices established and pertaining to such elevator design, construction, repair, alteration, and maintenance. The board may adopt existing published standards as well as amendments thereto subsequently published by the same authority. (B) Prescribe the tests that shall be used to ascertain the qual...

Section 4105.02 | Certificate of competency in elevator inspection.

...s the person holds a certificate of competency from the division of industrial compliance. Application for examination as an inspector of elevators shall be in writing, accompanied by a fee to be established as provided in section 4105.17 of the Revised Code, and upon a blank to be furnished by the division, stating the school education of the applicant, a list of the applicant's employers, the applicant's period o...

Section 4105.03 | Superintendent to hire assistant and general inspectors.

...rom the holders of certificates of competency.

Section 4105.04 | Employment or designation of special inspectors.

...es of competency in the inspection of elevators, any company that is authorized to insure elevators in the state, may designate persons to inspect elevators covered by such company's policies, and the department of public safety of any city and the clerk of any village may designate persons to inspect elevators in such city or village. Such persons shall, upon the payment of a fee to be established as provided...

Section 4105.05 | Suspension or revocation of special inspector's commission.

...f industrial compliance, for the incompetence or untrustworthiness of the holder thereof, or for the falsification of any matter or statement contained in the holder's application or in a report of any inspection.

Section 4105.06 | Lost certificate or commission.

...If a certificate or commission issued under sections 4105.02 and 4105.04 of the Revised Code is lost or destroyed a new one shall be issued in its place by the division of industrial compliance without another examination, upon the payment of a fee to be established as provided in section 4105.07 of the Revised Code.

Section 4105.07 | Insurance company may inspect.

...If an elevator is insured by a company authorized to insure elevators in the state, the inspection may be made by a special inspector of such company, and the only fee collectible by the state shall be the certificate fee provided for in section 4105.17 of the Revised Code.

Section 4105.08 | General inspector may inspect - fee.

...If an elevator is not inspected by a special inspector, the inspection shall be made by a general inspector, and for each inspection there shall be a fee charged as provided in section 4105.17 of the Revised Code.

Section 4105.09 | Registration of elevators.

...The owner or user of any elevator shall register, with the division of industrial compliance, every elevator operated by the owner or user, giving the type, capacity, and description, name of manufacturer, and purpose for which each is used. Such registration shall be made on a form to be furnished by the division.

Section 4105.10 | Frequency of inspection.

...s, permanently installed, either on or between rails or guides, shall be inspected at least once every twelve months. (3) The board of building standards may designate, by rule, classifications of passenger elevators with a capacity of seven hundred fifty pounds or less that shall be inspected once every twelve months. (B) Division (A) of this section does not apply to an elevator installed in a private residence...

Section 4105.11 | Responsibility for inspections - adjudication orders.

...on order shall specify what appliances, site preparations, additions, repairs, or alterations to any elevators, plans, materials, assemblages, or procedures are necessary for the same to comply with this chapter, or any rules adopted pursuant thereto. Such adjudication order shall be issued pursuant to Chapter 119. of the Revised Code and shall be effective without prior hearing, within thirty days after the re...

Section 4105.12 | Rules.

... and revocation of certificates of competency and certificates of operation, for the conduct of hearings related to these actions, and for the inspection of elevators. (B) Notwithstanding division (A) of this section, the superintendent shall not adopt rules relating to construction, maintenance, and repair of elevators.

Section 4105.13 | Safety equipment - vertical wheelchair lifts.

...s, guides, cables, doors, and gates, safety stops and mechanism, electrical apparatus and wiring, mechanical apparatus, counterweights, and all other appurtenances, in accordance with state laws and rules as are authorized in respect thereto. Where reasonable safety is obtained without complying to the literal requirements of such rules as in cases of practical difficulty or unnecessary hardship, the literal requirem...

Section 4105.14 | Seats for use of operator of passenger elevators.

..., or corporation operating a passenger elevator shall provide a seat for the use of the operator of such elevator. Any person, firm, or corporation operating a passenger elevator may regulate the use of such seats by the operator. At no time shall a person operating a passenger elevator be compelled to stand a longer period of time than two consecutive hours in any working day.

Section 4105.15 | Certificate of operation - renewal.

...No certificate of operation for any elevator shall be issued by the director of commerce until such elevator has been inspected as required by this chapter. Certificates of operation shall be renewed by the owner or user of the elevator in accordance with rules adopted by the superintendent of industrial compliance pursuant to section 4105.12 of the Revised Code.

Section 4105.16 | Permit for erection or repair - final inspection.

...ms to be furnished by the division, together with complete construction plans in duplicate. In all cases where any changes or repairs are made which alter its construction of classification, grade or rated lifting capacity, except when made pursuant to a report of an inspector, an application of specifications in duplicate shall be submitted to the division, containing such information, or approval, except in ...