Ohio Revised Code Search
Section |
---|
Section 1567.54 | Adequate fire protection - firefighting equipment.
...ch the only means of egress is by vertical shaft, the operator shall provide adequate fire protection to secure the safety of such shaft, and, when but one shaft is the only available means of egress, shall keep in attendance a competent person when persons are inside of such mine. Each underground coal mine shall be provided with suitable firefighting equipment adapted for the size and conditions of the mine. The c... |
Section 1567.55 | Report of coal seam fire - covering of exposed surface to prevent fire.
...s by the state. Whenever, after August 26, 1949, the surface of a natural deposit of coal is exposed by mining operations, the chief may order the owner, lessee, or agent of the mine at which such exposure occurs to cover such exposed surface with earth or other noncombustible material if, in the judgment of the chief, such covering is necessary to prevent a fire in the coal that would endanger life or property. Suc... |
Section 1567.57 | Two-way communication system.
...Every operator of a mine shall install and maintain in efficient working condition a system of two-way communications approved by the chief of the division of mineral resources management connecting the surface and each landing of main shafts and slopes between the surface and each working section of any coal mine that is more than one hundred feet from a portal. No operator of a mine shall refuse or neglect to comp... |
Section 1567.58 | Lights in mines.
...The operator of each mine shall provide an enclosed lard or signal oil lamp or lantern approved by the deputy mine inspector, or incandescent electric light, at such points in the mine as are necessary, including at the top of extreme grades and in underground stations where machinery is installed. No open light shall be used for fixed or stationary purposes, and no coal oil or kerosene lamp or lanterns shall be used... |
Section 1567.59 | Flame safety lamps.
...The operator of an underground coal mine shall keep on hand in proper condition for use not less than one approved flame safety lamp, other approved methane detector, or other approved device capable of detecting methane gas in equivalent quantities as a flame safety lamp, for each fifty men employed in said mine, and upon the order of the deputy mine inspector, shall provide such additional flame safety lamps or ap... |
Section 1567.60 | Recording pressure gauge.
...The operator of any underground mine shall have a U tube or recording pressure gauge for the purpose of recording pressure or vacuum of the main air current installed in such mine. A record of the readings of such gauge shall be kept in a book which shall be accessible to the deputy mine inspector and all of such records of readings shall be kept so accessible for not less than one year. No operator of a mine shall ... |
Section 1567.61 | First aid and emergency medical equipment - report of arrangements for emergency medical assistance and transportation.
...s used in this section, "emergency medical service organization" has the same meaning as in section 4765.01 of the Revised Code. The operator at all mines and quarries shall keep first aid and emergency medical equipment in a dry and sanitary condition in accessible places. Each operator shall report to the chief of the division of mineral resources management, the name, title, and address of each emergency medical... |
Section 1567.62 | Obstruction of airway.
...No person shall place refuse in or obstruct any airway or break-through used as an airway. |
Section 1567.63 | Use of traveling ways - loitering prohibited.
...Each employee of a mine shall go to and from his place of duty by the traveling ways provided. He shall not travel around the mine, or the buildings, tracks, or machinery connected therewith, where duty does not require, and when not on duty, he shall not loiter at, in, or around the mine, or the buildings, tracks, or machinery connected therewith. |
Section 1567.64 | Operator to provide tag lines or tie-off lines for miners.
... (B) The operator of an underground coal mine shall provide tag lines or tie-off lines for each miner at the mine. The operator shall provide and employees of the mine shall use tag lines or tie-off lines in accordance with requirements and procedures established in rules adopted under this section. (C) The chief of the division of mineral resources management, in consultation with a statewide association re... |
Section 1567.65 | Prohibition against smoking or carrying smoking materials.
...No person shall smoke or carry smoking materials or matches or lighters for smoking material in an underground coal mine or any underground gaseous metal or nonmetal mine. Smoking in nongaseous metal and nonmetal underground mines or in or about surface structures of any mine shall be restricted to places where it will not cause a fire or hazard. |
Section 1567.66 | Prohibition against intoxicants.
...No person shall go into, to, or around a mine, or the buildings, tracks, or machinery connected therewith, while under the influence of intoxicants. No person shall use, carry, or have in his possession any intoxicants at, in, or around a mine, or the buildings, tracks, or machinery connected therewith. |
Section 1567.67 | Protective clothing.
...Each man working in and about a mine shall exercise discretion in wearing such clothes as will protect him from injury and minimize the danger of getting clothing caught in machinery or other places. |
Section 1567.68 | Safety provisions for machinery and equipment.
...Coal spilled beneath belt conveyor drives or tail pieces shall not be removed while the conveyor is in motion, except where such coal can be removed without endangering persons. Mobile and stationary machinery and equipment shall be maintained in safe operating condition and machinery or equipment in unsafe condition shall be removed from service immediately. Machinery and equipment shall be operated only by person... |
Section 1567.681 | Fire detection devices required on conveyor belts.
...(A) The operator of an underground coal mine that uses conveyor belts in the operation of the mine shall install fire detection devices on each conveyor belt that is used in the mine. The fire detection devices shall be of a design and type established in rules adopted under this section. The chief of the division of mineral resources management shall inspect the fire detection devices after the operator of the... |
Section 1567.69 | Longwall mining plans or revisions - contents.
... and after July 20, 1984, no operator shall begin longwall mining in any coal mine until plans for the longwall mining have been filed with and approved by the chief of the division of mineral resources management. All revisions to approved plans shall also be submitted for approval to the chief. The chief shall not approve any plan or revision unless it meets the requirements of this section and shall approve all p... |
Section 1567.70 | Plan for recovery of longwall roof support - approval by chief.
...An operator conducting longwall mining shall develop a plan for recovery of chocks and shields or other longwall roof support and shall not initiate recovery until the recovery plan is approved by the chief of the division of mineral resources management. An operator shall also submit all revisions of an approved recovery plan for approval to the chief. Approval of a plan or revision, or portion thereof, under compa... |
Section 1567.71 | Two-way communication facilities.
...(A) An operator conducting longwall mining shall provide two-way communication facilities, approved by the chief of the division of mineral resources management, at the headgate and tailgate and across each longwall working face that, during the production of coal, are a separate system from the mine communication facilities. Longwall working section communication facilities shall be located at points not more than o... |
Section 1567.72 | De-energizing electrical power on longwall working face conveyor.
...(A) An operator conducting longwall mining shall provide all longwall working face conveyors installed on and after the effective date of this section with lock-out type de-energizing devices to de-energize the electrical power on the longwall working face conveyor. The de-energizing devices shall be provided at intervals of not more than fifty feet when the average height of the coal seam is at or below forty-eight ... |
Section 1567.73 | Installation of methane monitors.
...(A) The chief of the division of mineral resources management or the chief's representative shall require installation on a longwall working section of a federally approved methane monitor capable of giving warning automatically when the concentration of methane reaches a maximum percentage of not more than 1.0 volume per cent of methane. The sensoring unit indicating the atmospheric conditions on the methane monitor... |
Section 1567.74 | Safety requirements for longwall working face.
...(A) No person shall cross the longwall working face conveyor while it is in operation unless a safe crossover is provided. (B) The operator shall provide telephone pager communications or other means of providing an effective warning signal in a longwall working section. Prior to starting a longwall working face conveyor, the person who is going to activate the conveyor shall sound the telephone pager communications... |
Section 1567.75 | Cutting and welding.
...g and welding being performed on a longwall working section, methane gas examinations shall be made by a certified foreman or a person qualified to make the examinations designated by a certified foreman. No person shall perform cutting and welding when the methane gas concentration is one per cent or more. A certified foreman or person qualified to make examinations for gas shall be continuously present during all c... |
Section 1567.76 | Maintenance of hydraulic lines and roof support units.
...(A) An operator shall ensure that all hydraulic line repairs are performed in accordance with maintaining the functioning of the line at a level consistent with that at the time of initial installation of the line. (B) An operator shall ensure that all hydraulic roof support units and associated apparatus on a longwall working face are visually inspected at least once each day, at any time of the day, by a qualified... |
Section 1567.77 | First aid equipment.
...An operator shall maintain first aid equipment required on each working section by section 1567.61 of the Revised Code in the headgate entry at a point not to exceed one hundred fifty feet outby the longwall working face. No operator shall fail to comply with this section. |
Section 1567.78 | Maintaining accessible tailgate travel route.
...An operator shall maintain an accessible travel route at all times off the tailgate end of the longwall working face unless the operator develops and the chief of the division of mineral resources management approves a plan to continue operation of the longwall working section in the event the tailgate route becomes impassable. Such a plan shall include necessary provisions to be taken to provide additional protectiv... |