Skip to main content
Back To Top Top Back To Top
The Legislative Service Commission staff updates the Revised Code on an ongoing basis, as it completes its act review of enacted legislation. Updates may be slower during some times of the year, depending on the volume of enacted legislation.

Ohio Revised Code Search

Titles
Busy
 
Keywords
:
public ind
{"removedFilters":"","searchUpdateUrl":"\/ohio-revised-code\/search\/update-search","keywords":"public+ind","start":901,"pageSize":25,"sort":"BestMatch","title":""}
Results 901 - 925 of 4,960
Sort Options
Sort Options
Sort Options
Sections
Section
Section 4101.13 | Duties of employees.

...No employee shall remove, displace, damage, destroy, or carry off any safety device or safeguard furnished or provided for use in any employment or place of employment, or interfere in any way with the use thereof by any other person. No employee shall interfere with the use of any method or process adopted for the protection of any employee in such employment or place of employment, or frequenter of such place of em...

Section 4101.14 | Substantial compliance.

...A substantial compliance with the applicable sections of sections 4101.01 to 4101.16, inclusive, and 4121.01 to 4121.29, inclusive, of the Revised Code, is sufficient to give effect to orders, and such orders shall not be declared inoperative, illegal, or void for any omission of a technical nature in respect thereto.

Section 4101.15 | Prohibited acts.

...No employer, employee, or other person shall violate this chapter or Chapter 4121. of the Revised Code, do any act prohibited by such chapters, fail to perform any duty lawfully enjoined, within the time prescribed by the bureau of workers' compensation, for which violation no penalty has been specifically provided, or fail to obey any lawful order given or made by the bureau, or any judgment or decree made by ...

Section 4101.16 | Every day a separate violation.

...Every day during which any person, or corporation, or any officer, agent, or employee thereof fails to observe and comply with any order of the bureau of workers' compensation, or to perform any duty enjoined by this chapter and Chapter 4121. of the Revised Code, constitutes a separate violation of the order or chapters.

Section 4101.99 | Penalty.

...(A) Whoever violates section 4101.15 of the Revised Code shall be fined not less than fifty nor more than one thousand dollars for a first offense; for each subsequent offense such person shall be fined not less than one hundred nor more than five thousand dollars.

Section 4104.01 | Boiler definitions.

...rintendent" means the superintendent of industrial compliance created by section 121.04 of the Revised Code. (C) "Boiler" means a closed vessel in which water is heated, steam is generated, steam is superheated, or any combination thereof, under pressure or vacuum for use externally to itself by the direct application of heat from the combustion of fuels, or from electricity or nuclear energy. "Boiler" includes...

Section 4104.02 | Board of building standards - powers and duties.

...ation of fusible plugs, appliances for indicating the pressure of steam and level of water in the boiler or pressure vessels, and such other appliances as the board considers necessary to safety in operating boilers; (4) Adopt rules that prescribe the conditions and requirements for design, certification, reporting, installation, operation, and periodic testing and maintenance of controls and safety devices o...

Section 4104.03 | Rights of municipal corporations.

...Sections 4104.01 to 4104.20, inclusive, of the Revised Code do not affect the rights of municipal corporations under section 715.44 of the Revised Code insofar as such section provides for the regulation of the installation and inspection of boilers and boiler plants for the purpose of the prevention of the emission of smoke.

Section 4104.04 | Exemptions - safety devices.

...ed in the construction of and repair to public roads, railroads, and bridges; (7) Historical steam boilers of riveted construction, preserved, restored, or maintained for hobby or demonstration use.

Section 4104.05 | Operation of boilers and stationery steam engines.

...(A) Unless otherwise provided by the rules adopted by the board of building standards pursuant to division (A)(4) of section 4104.02 of the Revised Code, no person shall operate a low pressure steam boiler that has more than three hundred sixty square feet of heating surface, unless one of the following applies to that person: (1) The person is licensed as a steam engineer, high pressure boiler operator, or l...

Section 4104.06 | Inspectors - rules - right of entry.

...he Revised Code. The superintendent of industrial compliance shall administer and enforce such sections and rules adopted by the board of building standards pursuant to section 4104.02 of the Revised Code. (B) The superintendent shall adopt, amend, and repeal rules exclusively for the issuance, renewal, suspension, and revocation of certificates of competency and certificates of operation, for conducting hear...

Section 4104.07 | Inspector of boilers and unfired pressure vessels - application for examination - certification.

...o be furnished by the superintendent of industrial compliance. Any moneys collected under this section shall be paid into the state treasury to the credit of the industrial compliance operating fund created in section 121.084 of the Revised Code. (B) The superintendent shall determine if an applicant meets all the requirements for examination in accordance with rules adopted by the board of building standards under...

Section 4104.08 | Director of commerce may appoint general and special inspectors.

...petency issued by the superintendent of industrial compliance, or holders of certificates of competency or commissions issued by other states or nations whose examinations for certificates or commissions have been approved by the board of building standards, persons to inspect and stamp boilers and pressure vessels covered by the company's policies, and the superintendent shall issue to such persons commissions autho...

Section 4104.09 | Revoking certificate of competency or commission.

...may be revoked by the superintendent of industrial compliance for the incompetence of the holder thereof, or for willful falsification of any matter or statement contained in the holder's application or in a report of any inspection in accordance with Chapter 119. of the Revised Code. If a certificate or commission is lost or destroyed, a new certificate or commission shall be issued in its place without another exam...

Section 4104.10 | Inspection of unfired pressure vessels.

...in the office of the superintendent of industrial compliance. All unfired pressure vessels shall conform in every detail with applicable rules adopted by the board of building standards pursuant to section 4104.02 of the Revised Code.

Section 4104.101 | Registration and permits from division of industrial compliance.

...gistering to do so with the division of industrial compliance. (B) No person shall make any installation or major repair or modification of any boiler without first obtaining a permit to do so from the division. The permit application form shall provide the name and address of the owner, location of the boiler, and type of repair or modification that will be made. The application permit fee shall be one hundred dol...

Section 4104.11 | Inspecting boilers.

...(A) All power boilers and high pressure, high temperature water boilers and their appurtenances shall be thoroughly inspected internally and externally and under operating conditions at intervals of not more than one year, unless approved for biennial inspection under section 4104.13 of the Revised Code, and shall not be operated at pressures in excess of the safe working pressure stated in the certificate of operati...

Section 4104.12 | Inspecting boiler installation.

...s been issued by the superintendent of industrial compliance. The certificate of operation required by this section shall not be issued for any boiler which has not been thoroughly inspected during construction and upon completion, by either a general or special inspector, and which does not conform in every detail with the rules adopted by the board of building standards and unless, upon completion, such boile...

Section 4104.13 | Interval inspection of boilers.

...Power boilers and high pressure, high temperature water boilers having internal continuous water treatment under the general supervision of a registered professional engineer having experience in the treatment of boiler water where said water treatment is for the purpose of controlling and limiting serious corrosion, and other deteriorating factors shall be thoroughly inspected internally and externally and under ope...

Section 4104.14 | Preparing boiler for inspection.

...the safety valve and the appliances for indicating the pressure and level of water in the boiler are in proper working order. No person shall remove or tamper with any safety appliances prescribed by the board of building standards, and no person shall in any manner load the safety valve to a greater pressure than that allowed by the certificate of operation. If in the judgment of the inspector it is advisable to ap...

Section 4104.15 | Certificates of inspection and operation.

...oner withdrawn by the superintendent of industrial compliance. The owner or user of any such boiler shall obtain an appropriate certificate of operation for such boiler, and shall not operate such boiler, or permit it to be operated unless a certificate of operation has been obtained in accordance with section 4104.17 of the Revised Code. (B) If a boiler owner or user is in compliance with sections 4104.13, 4104.17,...

Section 4104.16 | Notifying superintendent of the division of industrial compliance of safety defect or of relocation.

...mmediately notify the superintendent of industrial compliance in case a defect affecting the safety of the boiler is discovered. The owner or user of any stationary boiler required by such sections to be inspected, who moves the same, shall report to the superintendent the new location of the boiler. Such boiler shall be inspected before it is again operated.

Section 4104.17 | Certificates of operation - issuance and renewal.

...tions adopted by the superintendent of industrial compliance.

Section 4104.18 | Fees.

...ion, shall pay to the superintendent of industrial compliance an initial certificate of operation fee in the following amount, as applicable: (1) Fifty dollars for boilers subject to annual inspections under section 4104.11 of the Revised Code; (2) One hundred dollars for boilers subject to biennial inspection under section 4104.13 of the Revised Code; (3) One hundred fifty dollars for boilers subject to trienn...

Section 4104.19 | Operator's license.

... application with the superintendent of industrial compliance on a form prescribed by the superintendent with the appropriate application fee as set forth in section 4104.18 of the Revised Code. The application shall contain information satisfactory to the superintendent to demonstrate that the applicant meets the requirements of division (B) of this section. The application shall be filed with the superintendent not...