Skip to main content
Back To Top Top Back To Top
This website publishes administrative rules on their effective dates, as designated by the adopting state agencies, colleges, and universities.

Rule 3701:1-52-21 | Radiation surveys.

 

(A) A radiation survey of the area outside the shielding of the radiation room of a panoramic irradiator must be conducted with the sources in the exposed position before the facility starts to operate. A radiation survey of the area above the pool for pool irradiators must be conducted after the sources are loaded but before the facility starts to operate. Additional radiation surveys of the shielding must be performed at intervals not to exceed three years and before resuming operation after addition of new sources or any modification to the radiation room shielding or structure that might increase dose rates.

(B) If the radiation levels specified in rule 3701:1-52-09 of the Administrative Code are exceeded, the facility must be modified to comply with the requirements in rule 3701:1-52-09 of the Administrative Code.

(C) Portable radiation survey meters must be calibrated at least annually to an accuracy of plus or minus twenty per cent for the gamma energy of the sources in use. The calibration must be done at two points on each scale or, for digital instruments, at one point per decade over the range that will be used. Portable radiation survey meters must be of a type that does not saturate and read zero at high radiation dose rates.

(D) Water from the irradiator pool, other potentially contaminated liquids, and sediments from pool vacuuming must be monitored for radioactive contamination before release to unrestricted areas. Radioactive concentrations must not exceed those specified in accordance with table II or table III of appendix C to rule 3701:1-38-12 of the Administrative Code, "Annual Limits on Intake (ALI) and Derived Air Concentrations (DAC) of Radionuclides for Occupational Exposure; Effluent Concentrations; Concentrations for Release to Sanitary Sewerage".

(E) Before releasing resins for unrestricted use, they must be monitored before release in an area with a background level less than 0.5 microsievert (0.05 millirem) per hour. The resins may be released only if the survey does not detect radiation levels above background radiation levels. The survey meter used must be capable of detecting radiation levels of 0.5 microsievert (0.05 millirem) per hour.

Last updated August 1, 2023 at 2:41 PM

Supplemental Information

Authorized By: 3748.04
Amplifies: 3748.04
Five Year Review Date: 4/19/2027
Prior Effective Dates: 10/20/2002