Rule |
---|
Rule 3701:1-46-37 | Calibration or reference sources containing americium-241 or radium-226: requirements for license to manufacture or initially transfer.
...eference sources containing americium-241 or radium-226, for distribution to persons generally licensed under rule 3701:1-46-08 of the Administrative Code, will be approved if: (A) The applicant satisfies the general requirements of rule 3701:1-40-15 of the Administrative Code; (B) The applicant submits sufficient information regarding each type of calibration or reference source pertinent to evaluation of the pote... |
Rule 3701:1-46-38 | Calibration or reference sources containing americium-241 or radium-226: labeling of devices.
...(A) Each person licensed under rule 3701:1-46-37 of the Administrative Code shall affix to each source, or storage container for the source, a label which shall contain sufficient information relative to safe use and storage of the source and shall include one of the following statements or a substantially similar statement which contains the information called for in one of the following statements: (1) For americi... |
Rule 3701:1-46-39 | Calibration or reference sources containing americium-241 or radium-226: leak testing of each source.
...Each person licensed under rule 3701:1-46-37 of the Administrative Code shall perform a dry wipe test upon each source containing more than 3.7 kilobecquerels (0.1 microcurie) of americium-241 or radium-226 prior to transferring the source to a general licensee under rule 3701:1-46-08 of the Administrative Code. This test shall be performed by wiping the entire radioactive surface of the source with a filter paper wi... |
Rule 3701:1-46-40 | Ice detection devices containing strontium-90; requirements for license to manufacture or initially transfer.
...ersons generally licensed under rule 3701:1-46-10 of the Administrative Code will be approved if: (A) The applicant satisfies the general requirements specified in rule 3701:1-40-15 of the Administrative Code; (B) The applicant submits sufficient information regarding each type of device pertinent to evaluation of the potential radiation exposure, including: (1) Chemical and physical form and maximum quantity of s... |
Rule 3701:1-46-41 | Ice detection devices containing strontium-90: quality assurance; prohibition of transfer.
...(A) Each person licensed under rule 3701:1-46-40 of the Administrative Code shall visually inspect each device and shall reject any which has an observable physical defect that could affect containment of the strontium-90. (B) Each person licensed under rule 3701:1-46-40 of the Administrative Code shall test each device for possible loss of strontium-90 or for contamination by wiping with filter paper an area of at ... |
Rule 3701:1-46-42 | Manufacture and distribution of radioactive material for certain in-vitro clinical or laboratory testing under general license.
...se under the general license in rule 3701:1-46-11 of the Administrative Code will be approved if: (A) The applicant satisfies the general requirements specified in rule 3701:1-40-15 of the Administrative Code. (B) The radioactive material is to be prepared for distribution in prepackaged units of: (1) Iodine-125 in units not exceeding 0.37 megabecquerel (ten microcuries) each. (2) Iodine-131 in units not exceedin... |
Rule 3701:1-46-42 | Manufacture and distribution of radioactive material for certain in-vitro clinical or laboratory testing under general license.
... under the general license in rule 3701:1-46-11 of the Administrative Code will be approved if: (A) The applicant satisfies the general requirements specified in rule 3701:1-40-15 of the Administrative Code. (B) The radioactive material is to be prepared for distribution in prepackaged units of: (1) Iodine-125 in units not exceeding 0.37 megabecquerel (ten microcuries) each. (2) Iodine-131 in ... |
Rule 3701:1-46-43 | Manufacture, preparation, or transfer for commercial distribution of radioactive drugs containing radioactive material for medical use.
...rsons authorized pursuant to Chapter 3701:1-58 of the Administrative Code or equivalent regulations of an agreement state will be approved if: (1) The applicant satisfies the general requirements specified in rule 3701:1-40-15 of the Administrative Code; (2) The applicant submits evidence that the applicant is at least one of the following: (a) Registered with the United States food and drug administration as the ... |
Rule 3701:1-46-43 | Manufacture, preparation, or transfer for commercial distribution of radioactive drugs containing radioactive material for medical use.
...rsons authorized pursuant to Chapter 3701:1-58 of the Administrative Code or equivalent regulations of an agreement state will be approved if: (1) The applicant satisfies the general requirements specified in rule 3701:1-40-15 of the Administrative Code; (2) The applicant submits evidence that the applicant is at least one of the following: (a) Registered with the United States food and drug administration as the ... |
Rule 3701:1-46-44 | Manufacture and distribution of sources or devices containing radioactive material for medical use.
...persons licensed pursuant to Chapter 3701:1-58 of the Administrative Code or equivalent regulations of the United States nuclear regulatory commission or agreement state for use as a calibration, transmission, or reference source or for the uses listed in rules 3701:1-58-43, 3701:1-58-53, 3701:1-58-55, and 3701:1-58-72 of the Administrative Code or equivalent regulations of the United States nuclear regulatory commis... |
Rule 3701:1-46-49 | Registration of product information.
...46 North High Street Columbus, Ohio 43215" (C) The request for review of a sealed source or a device must include sufficient information about the design, manufacture, prototype testing, quality control program, labeling, proposed uses and leak testing and, for a device, the request must also include sufficient information about installation, service and maintenance, operating and safety instructions, and its poten... |
Rule 3701:1-46-51 | General license for certain items and self-luminous products containing radium-226.
...ufactured prior to November 30, 2007: (1) Antiquities originally intended for use by the general public. For the purposes of this paragraph, antiquities mean products originally intended for use by the general public and distributed in the late nineteenth and early twentieth centuries, such as radium emanator jars, revigators, radium water jars, radon generators, refrigerator cards, radium bath salts, and healing pa... |
Rule 3701:1-48-01 | Definitions.
...Terms defined in rule 3701:1-38-01 of the Administrative Code shall have the same meaning when used in this chapter except terms redefined within a given rule for use within that rule only, and additionally, as used in this chapter: (A) "Annual Refresher Safety Training" means a review conducted or provided by the licensee for its employees on radiation safety aspects of industrial radiography. The review may includ... |
Rule 3701:1-48-04 | Specific license for industrial radiography.
...neral requirements specified in rule 3701:1-40-15 of the Administrative Code for radioactive material, as appropriate, and any special requirements contained in this chapter. (B) The applicant submits an adequate program for training radiographers and radiographers' assistants that meets the requirements of rule 3701:1-48-16 of the Administrative Code. (C) The applicant submits procedures for verifying and document... |
Rule 3701:1-48-05 | Performance requirements for industrial radiography equipment.
...he following minimum criteria: (A) (1) Each radiographic exposure device, source assembly or sealed source, and all associated equipment must meet the requirements specified in american national standards institute, N432-1980 "Radiological Safety for the Design and Construction of Apparatus for Gamma Radiography," (published as NBS handbook 136, issued January 1981). This publication may be pu... |
Rule 3701:1-48-07 | Locking of radiographic exposure devices, storage containers and source containers.
...phic installations as stated in rule 3701:1-48-21 of the Administrative Code. In addition, during radiographic operations the sealed source assembly must be secured in the shielded position each time the source is returned to that position. (B) Each sealed source storage container and source changer must have a lock or outer locked container designed to prevent unauthorized or accidental removal of the sealed source... |
Rule 3701:1-48-08 | Radiation survey instruments.
...required by this chapter and Chapter 3701:1-38 of the Administrative Code. Instrumentation required by this rule must be capable of measuring a range from 0.02 millisievert (two millirem) per hour through 0.01 sievert (one rem) per hour. (B) The licensee shall have each radiation survey instrument required under paragraph (A) of this rule calibrated: (1) At intervals not to exceed six months and after instrument se... |
Rule 3701:1-48-09 | Leak testing and replacement of sealed sources.
...r an agreement state to do so. (C) (1) Each licensee who uses a sealed source shall have the source tested for leakage at intervals not to exceed six months. The leak testing of the source must be performed using a method approved by the director, the United States nuclear regulatory commission or by an agreement state. The wipe sample should be taken from the nearest accessible point to the sealed source where c... |
Rule 3701:1-48-10 | Quarterly inventory.
...ccordance with paragraph (E) of rule 3701:1-48-23 of the Administrative Code. |
Rule 3701:1-48-11 | Inspection and maintenance of radiographic exposure devices, transport and storage containers, associated equipment, source changers, and survey instruments.
...ee shall have written procedures for: (1) Inspection and routine maintenance of radiographic exposure devices, source changers, associated equipment, transport and storage containers, and survey instruments at intervals not to exceed three months or before the first use thereafter to ensure the proper functioning of components important to safety. Replacement components shall meet design specifications. If equipment... |
Rule 3701:1-48-12 | Permanent radiographic installations.
...raphic installation must have either: (1) An entrance control of the type described in paragraph (A) of rule 3701:1-38-15 of the Administrative Code that reduces the radiation level upon entry into the area; or (2) Both conspicuously visible and audible warning signals to warn of the presence of radiation. The visible signal must be actuated by radiation whenever the source is exposed. The audible signal must be ac... |
Rule 3701:1-48-13 | Labeling, storage, and transportation.
...ng papers in accordance with Chapter 3701:1-50 of the Administrative Code. (C) Locked radiographic exposure devices and storage containers must be physically secured to prevent tampering or removal by unauthorized personnel. The licensee shall store licensed material in a manner which will minimize danger from explosion or fire. (D) The licensee shall lock and physically secure the transport package containing lice... |
Rule 3701:1-48-14 | Conducting industrial radiographic operations.
...equirements of paragraph (C) of rule 3701:1-48-16 of the Administrative Code. The additional qualified individual shall observe the operations and be capable of providing immediate assistance to prevent unauthorized entry. Radiography may not be performed if only one qualified individual is present. (B) All radiographic operations conducted at locations of use authorized on the license must be conducted in a permane... |
Rule 3701:1-48-15 | Radiation safety officer for industrial radiography.
...ndustrial radiography are as follows: (1) Completion of the training and testing requirements of paragraph (A) of rule 3701:1-48-16 of the Administrative Code; (2) Two thousand hours of hands-on experience as a qualified radiographer in industrial radiographic operations; and (3) Formal training in the establishment and maintenance of a radiation protection program. (B) The director will consider alternatives to ... |
Rule 3701:1-48-16 | Training.
... a radiographer until the individual: (1) Has received copies of and instruction in the requirements described in this chapter, Chapter 3701:1-38, and rule 3701:1-40-05 of the Administrative Code; in applicable regulations as specified in Chapter 3701:1-50 of the Administrative Code; in the Ohio license(s) under which the radiographer will perform industrial radiography; and the licensee's operating and emergency pr... |