Rule 3701:1-58-54 | Training for use of sealed sources and medical devices for diagnosis.
...Except as provided in rule 3701:1-58-21 of the Administrative Code, the licensee shall require the authorized user of a diagnostic sealed source or a device authorized under rule 3701:1-58-53 of the Administrative Code to be a physician, dentist, or podiatrist who: (A) Is certified by a specialty board whose certification process includes all of the requirements in paragraphs (C) and (D) of this rule a... |
Rule 3701:1-58-55 | Use of a sealed source in a remote afterloader unit, teletherapy unit, or gamma stereotactic radiosurgery unit.
...equirements of paragraph (A) of rule 3701:1-58-17 of the Administrative Code are met. |
Rule 3701:1-58-55 | Use of a sealed source in a remote afterloader unit, teletherapy unit, or gamma stereotactic radiosurgery unit.
...see must only use sealed sources: (1) Approved and as provided for in the sealed source and device registry in photon emitting remote afterloader units, teletherapy units, or gamma stereotactic radiosurgery units to deliver therapeutic doses for medical uses; or (2) In research involving photon-emitting remote afterloader units, teletherapy units, or gamma stereotactic radiosurgery units in ... |
Rule 3701:1-58-56 | Surveys of patients and human research subjects treated with a remote afterloader unit.
...hese surveys in accordance with rule 3701:1-58-87 of the Administrative Code. |
Rule 3701:1-58-57 | Installation, maintenance, adjustment, and repair of remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units.
...urgery units in accordance with rule 3701:1-58-91 of the Administrative Code. |
Rule 3701:1-58-58 | Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units.
...(A) A licensee shall: (1) Secure the unit, the console, the console keys, and the treatment room when not in use or unattended; (2) Permit only individuals approved by the authorized user, radiation safety officer, or authorized medical physicist to be present in the treatment room during treatment with the source(s); (3) Prevent dual operation of more than one radiation producing device in a treatment room if app... |
Rule 3701:1-58-58 | Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units.
...(A) A licensee shall: (1) Secure the unit, the console, the console keys, and the treatment room when not in use or unattended; (2) Permit only individuals approved by the authorized user, radiation safety officer, or authorized medical physicist to be present in the treatment room during treatment with the source(s); (3) Prevent dual operation of more than one radiation producing device in... |
Rule 3701:1-58-60 | Dosimetry equipment.
...following two conditions must be met: (1) The system must have been calibrated using a system or source traceable to the "National Institute of Standards and Technology" (NIST) and published protocols accepted by nationally recognized bodies; or by a calibration laboratory accredited by the "American Association of Physicists in Medicine" (AAPM). The calibration must have been performed within the previous two yea... |
Rule 3701:1-58-61 | Full calibration measurements on teletherapy units.
...easurements on each teletherapy unit: (1) Before the first medical use of the unit; (2) Before medical use under the following conditions: (a) Whenever spot-check measurements, as described in rule 3701:1-58-64 of the Administrative Code, indicate that the output differs by more than five per cent from the output obtained at the last full calibration corrected mathematically for radioactive decay; (b) Following r... |
Rule 3701:1-58-62 | Full calibration measurements on remote afterloader units.
...alibration measurements on each unit: (1) Before the first medical use of the unit; (2) Before medical use under the following conditions: (a) Following replacement of the source or following reinstallation of the unit in a new location outside the facility; and (b) Following any repair of the unit that includes removal of the source or major repair of the components associated with the source exposure assembly; ... |
Rule 3701:1-58-63 | Full calibration measurements on gamma stereotactic radiosurgery units.
...alibration measurements on each unit: (1) Before the first medical use of the unit; (2) Before medical use under the following conditions: (a) Whenever spot-check measurements, as described in rule 3701:1-58-66 of the Administrative Code, indicate that the output differs by more than five per cent from the output obtained at the last full calibration corrected mathematically for radioactive decay; (b) Following ... |
Rule 3701:1-58-64 | Periodic spot-checks for teletherapy units.
... month that include determination of: (1) Timer accuracy, and timer linearity over the range of use; (2) On-off error; (3) The coincidence of the radiation field and the field indicated by the light beam localizing device; (4) The accuracy of all distance measuring and localization devices used for medical use; (5) The output for one typical set of operating conditions measured with the dosimetry system describe... |
Rule 3701:1-58-65 | Periodic spot-checks for remote afterloader units.
...fterloader facility and on each unit: (1) Before the first use on any given day that a high dose-rate, medium dose-rate, or pulsed dose-rate remote afterloader is in operation; (2) Before each patient treatment with a low dose-rate remote afterloader unit; and (3) After each source installation. (B) A licensee shall perform the measurements required by paragraph (A) of this rule in accordance with written procedu... |
Rule 3701:1-58-66 | Periodic spot-checks for gamma stereotactic radiosurgery units.
...diosurgery facility and on each unit: (1) Monthly; (2) Before the first use of the unit on a given day; and (3) After each source installation. (B) A licensee shall: (1) Perform the measurements required by paragraph (A) of this rule in accordance with written procedures established by the authorized medical physicist. That individual need not actually perform the spot-check measurements. (2) Have the authoriz... |
Rule 3701:1-58-67 | Additional technical requirements for mobile remote afterloader units.
...ile remote afterloader service shall: (1) Check survey instruments before medical use at each address of use or on each day of use, whichever is more frequent; and (2) Account for all sources before departure from a client's address of use. (B) In addition to the periodic spot-checks required by rule 3701:1-58-65 of the Administrative Code, a licensee authorized to use mobile afterloaders for medical use shall per... |
Rule 3701:1-58-68 | Radiation surveys for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units.
...on to the survey requirement in rule 3701:1-38-14 of the Administrative Code, a person subject to rules 3701:1-58-55 to 3701:1-58-71 of the Administrative Code shall make surveys to ensure that the maximum radiation levels and average radiation levels from the surface of the main source safe with the source(s) in the shielded position do not exceed the levels stated in the sealed source and device registry. (B) The ... |
Rule 3701:1-58-69 | Five-year inspection for teletherapy and gamma stereotactic radiosurgery units.
...nd servicing in accordance with rule 3701:1-58-100 of the Administrative Code. |
Rule 3701:1-58-69 | Full-inspection servicing for teletherapy and gamma stereotactic radiosurgery units.
...nd servicing in accordance with rule 3701:1-58-100 of the Administrative Code. |
Rule 3701:1-58-71 | Training for use of remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units.
...Except as provided in rule 3701:1-58-21 of the Administrative Code, the licensee shall require an authorized user of a sealed source for a use authorized under rule 3701:1-58-55 of the Administrative Code to be a physician who: (A) Is certified by a medical specialty board whose certification process has been recognized by the director, United States nuclear regulatory commission, or an agreement state and who meets... |
Rule 3701:1-58-71 | Training for use of remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units.
...Except as provided in rule 3701:1-58-21 of the Administrative Code, the licensee shall require an authorized user of a sealed source for a use authorized under rule 3701:1-58-55 of the Administrative Code to be a physician who: (A) Is certified by a medical specialty board whose certification process has been recognized by the director, the United States nuclear regulatory commission, or an agreement s... |
Rule 3701:1-58-71 | Training for use of remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units.
...Except as provided in rule 3701:1-58-21 of the Administrative Code, the licensee shall require an authorized user of a sealed source for a use authorized under rule 3701:1-58-55 of the Administrative Code to be a physician who: (A) Is certified by a medical specialty board whose certification process has been recognized by the director, the United States nuclear regulatory commission, or an agreement s... |
Rule 3701:1-58-72 | Other medical uses of radioactive material or radiation from radioactive material.
...not specifically addressed in rules 3701:1-58-32, 3701:1-58-34, 3701:1-58-37, 3701:1-58-43, 3701:1-58-53 and 3701:1-58-55 of the Administrative Code if: (A) The applicant or licensee has submitted the information required by paragraphs (B) to (D) of rule 3701:1-58-07 of the Administrative Code; and (B) The applicant or licensee has received written approval from the director in a license or license amendment and u... |
Rule 3701:1-58-73 | Records of authority and responsibilities for radiation protection programs.
...ccordance with paragraph (A) of rule 3701:1-58-12 of the Administrative Code for five years. The record must include a summary of the actions taken and a signature of licensee management. (B) The licensee shall retain a copy of both authority, duties, and responsibilities of the radiation safety officer as required by paragraph (E) of rule 3701:1-58-12 of the Administrative Code, and a signed copy of each radiation... |
Rule 3701:1-58-73 | Records of authority and responsibilities for radiation protection programs.
...dance with paragraph (A) of rule 3701:1-58-12 of the Administrative Code for five years. The record must include a summary of the actions taken and a signature of licensee management. (B) The licensee shall retain a record of the authority, duties, and responsibilities of the radiation safety officer as required by paragraph (E) of rule 3701:1-58-12 of the Administrative Code, and a signed co... |
Rule 3701:1-58-74 | Records of radiation protection program changes.
...ccordance with paragraph (A) of rule 3701:1-58-13 of the Administrative Code for five years. The record must include a copy of the old and new procedures, the effective date of the change, and the signature of the licensee management that reviewed and approved the change. |