Ohio Administrative Code Search
Rule |
---|
Rule 3745-205-63 | Test methods and procedures - equipment leaks.
...mply with the following requirements: (1) Monitoring shall comply with reference method 21 in 40 CFR Part 60. (2) The detection instrument shall meet the performance criteria of reference method 21. (3) The instrument shall be calibrated before use on each day of its use by the procedures specified in reference method 21. (4) Calibration gases shall be: (a) Zero air (less than ten parts p... |
Rule 3745-205-64 | Recordkeeping - equipment leaks.
...(A) (1) Each owner or operator subject to rules 3745-205-50 to 3745-205-65 of the Administrative Code shall comply with the recordkeeping requirements of this rule. (2) An owner or operator of more than one hazardous waste management unit subject to rules 3745-205-50 to 3745-205-65 of the Administrative Code may comply with the recordkeeping requirements for these hazardous waste management un... |
Rule 3745-205-80 | Applicability and definitions - air emission standards for tanks, surface impoundments, and containers.
...o 3745-55-79, 3745-55-90 to 3745-55-100, or 3745-56-20 to 3745-56-32 of the Administrative Code except as rule 3745-54-01 of the Administrative Code and paragraph (B) of this rule provide otherwise. (B) Rules 3745-205-80 to 3745-205-90 of the Administrative Code do not apply to the following waste management units at the facility: (1) A waste management unit that holds hazardous waste placed... |
Rule 3745-205-80 | Applicability and definitions - air emission standards for tanks, surface impoundments, and containers.
...745-55-79, or 3745-55-90 to 3745-55-100, or 3745-56-20 to 3745-56-32 of the Administrative Code, except as rule 3745-54-01 of the Administrative Code and paragraph (B) of this rule provide otherwise. (B) Rules 3745-205-80 to 3745-205-90 of the Administrative Code do not apply to the following waste management units at the facility: (1) A waste management unit that holds hazardous waste place... |
Rule 3745-205-82 | Tanks, surface impoundments, and containers.
...agement unit is one of the following: (1) A tank, surface impoundment, or container for which all hazardous waste entering the unit has an average volatile organic (VO) concentration at the point of waste origination of less than five hundred parts per million by weight (ppmw). The average VO concentration shall be determined using the procedures specified in paragraph (A) of rule 3745-205-83 of ... |
Rule 3745-205-82 | Tanks, surface impoundments, and containers.
...agement unit is one of the following: (1) A tank, surface impoundment, or container for which all hazardous waste entering the unit has an average volatile organic (VO) concentration at the point of waste origination of less than five hundred parts per million by weight (ppmw). The average VO concentration shall be determined using the procedures specified in paragraph (A) of rule 3745-205-83 of ... |
Rule 3745-205-83 | Waste determination procedures - air emission standards for tanks, surface impoundments, and containers.
...t the point of waste origination. (1) An owner or operator shall determine the average VO concentration at the point of waste origination for each hazardous waste placed in a waste management unit exempted under paragraph (C)(1) of rule 3745-205-82 of the Administrative Code from using air emission controls in accordance with standards specified in rules 3745-205-84 to 3745-205-87 of the Admi... |
Rule 3745-205-84 | Tanks - air emission standards for tanks, surface impoundments, and containers.
...following requirements as applicable: (1) For a tank that manages hazardous waste that meets all of the conditions specified in paragraphs (B)(1)(a) to (B)(1)(c) of this rule, the owner or operator shall control air pollutant emissions from the tank in accordance with the "Tank Level 1" controls specified in paragraph (C) of this rule or the "Tank Level 2" controls specified in paragraph (D) of t... |
Rule 3745-205-85 | Surface impoundments - air emission standards for tanks, surface impoundments, and containers.
... operating either of the following: (1) A floating membrane cover in accordance with the provisions specified in paragraph (C) of this rule; or (2) A cover that is vented through a closed-vent system to a control device in accordance with the provisions specified in paragraph (D) of this rule. (C) The owner or operator who controls air pollutant emissions from a surface impoundment using a fl... |
Rule 3745-205-86 | Containers - air emission standards for tanks, surface impoundments, and containers.
...n control. (B) General requirements. (1) The owner or operator shall control air pollutant emissions from each container subject to this rule in accordance with the following requirements, as applicable to the container, except when the special provisions for waste stabilization processes specified in paragraph (B)(2) of this rule apply to the container. (a) For a container having a design capacity... |
Rule 3745-205-87 | Closed-vent systems and control devices - air emission standards for tanks, surface impoundments, and containers.
... meet the following requirements: (1) The closed-vent system shall route the gases, vapors, and fumes emitted from the hazardous waste in the waste management unit to a control device that meets the requirements specified in paragraph (C) of this rule. (2) The closed-vent system shall be designed and operated in accordance with the requirements specified in paragraph (K) of rule 3745-205-33 ... |
Rule 3745-205-87 | Closed-vent systems and control devices - air emission standards for tanks, surface impoundments, and containers.
... meet the following requirements: (1) The closed-vent system shall route the gases, vapors, and fumes emitted from the hazardous waste in the waste management unit to a control device that meets the requirements specified in paragraph (C) of this rule. (2) The closed-vent system shall be designed and operated in accordance with the requirements specified in paragraph (K) of rule 3745-205-33 ... |
Rule 3745-205-89 | Recordkeeping - air emission standards for tanks, surface impoundments, and containers.
... include the following information: (1) For each tank using air emission controls in accordance with the requirements of rule 3745-205-84 of the Administrative Code, the owner or operator shall record: (a) A tank identification number (or other unique identification description as selected by the owner or operator). (b) A record for each inspection required by rule 3745-205-84 of the Administrati... |
Rule 3745-205-90 | Reporting - air emission standards for tanks, surface impoundments, and containers.
... conditions specified in paragraph (C)(1) or (C)(2) of rule 3745-205-82 of the Administrative Code, as applicable. Examples of such occurrences include placing in the waste management unit a hazardous waste having an average VO concentration equal to or greater than five hundred parts per million by weight (ppmw) at the point of waste origination; or placing in the waste management unit a treated... |
Rule 3745-205-100 | Applicability- containment buildings.
...Rules 3745-205-100 to 3745-205-102 of the Administrative Code apply to owners or operators who store or treat hazardous waste in units designed and operated under rule 3745-205-101 of the Administrative Code. The owner or operator is not subject to the definition of "land disposal" in rule 3745-270-02 of the Administrative Code, provided that the unit meets the following requirements: (A) Is a completely enclosed, s... |
Rule 3745-205-100 | Applicability- containment buildings.
...Rules 3745-205-100 to 3745-205-102 of the Administrative Code apply to owners or operators who store or treat hazardous waste in units designed and operated under rule 3745-205-101 of the Administrative Code. The owner or operator is not subject to the definition of "land disposal" in rule 3745-270-02 of the Administrative Code, provided that the unit meets the following requirements: (A) Is a completely e... |
Rule 3745-205-101 | Design and operating standards for containment buildings.
... with the following design standards: (1) The containment buildings shall be completely enclosed with a floor, walls, and a roof to prevent exposure to the elements (e.g., precipitation, wind, run-on), and to assure containment of managed wastes. (2) The floor and containment walls of the unit, including the secondary containment system if required under paragraph (B) of this rule, shall be designed and constructed... |
Rule 3745-205-101 | Design and operating standards for containment buildings.
... with the following design standards: (1) The containment buildings shall be completely enclosed with a floor, walls, and a roof to prevent exposure to the elements (e.g., precipitation, wind, run-on), and to assure containment of managed wastes. (2) The floor and containment walls of the unit, including the secondary containment system if required under paragraph (B) of this rule, shall be desi... |
Rule 3745-256-30 | Applicability and definitions - air emission standards for process vents.
...except as provided in rule 3745-65-01 of the Administrative Code). (B) Except for paragraphs (D) and (E) of rule 3745-256-34 of the Administrative Code, rules 3745-256-30 to 3745-256-35 of the Administrative Code apply to process vents associated with distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operations that manage hazardous wastes with orga... |
Rule 3745-256-30 | Applicability and definitions - air emission standards for process vents.
...except as provided in rule 3745-65-01 of the Administrative Code). (B) Except for paragraphs (D) and (E) of rule 3745-256-34 of the Administrative Code, rules 3745-256-30 to 3745-256-35 of the Administrative Code apply to process vents associated with distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping operations that manage hazardous wastes with orga... |
Rule 3745-256-33 | Closed-vent systems and control devices - process vents.
...(A) (1) Owners or operators of closed-vent systems and control devices used to comply with rules 3745-256-30 to 3745-256-35 of the Administrative Code shall comply with this rule. (2) (a) The owner or operator of an existing facility who cannot install a closed-vent system and control device to comply with rules 3745-256-30 to 3745-256-35 of the Administrative Code on the effective date t... |
Rule 3745-256-33 | Closed-vent systems and control devices - process vents.
...(A) (1) Owners or operators of closed-vent systems and control devices used to comply with rules 3745-256-30 to 3745-256-35 of the Administrative Code shall comply with this rule. (2) (a) The owner or operator of an existing facility who cannot install a closed-vent system and control device to comply with rules 3745-256-30 to 3745-256-35 of the Administrative Code on the effective date that the facility becomes... |
Rule 3745-256-34 | Test methods and procedures - process vents.
...mply with the following requirements: (1) Monitoring shall comply with reference method 21 in 40 CFR Part 60. (2) The detection instrument shall meet the performance criteria of reference method 21. (3) The instrument shall be calibrated before use on each day of its use by the procedures specified in reference method 21. (4) Calibration gases shall be: (a) Zero air (less than ten parts per million (ppm) of hydr... |
Rule 3745-256-35 | Recordkeeping - process vents.
...(A) (1) Each owner or operator subject to rules 3745-256-30 to 3745-256-35 of the Administrative Code shall comply with the recordkeeping requirements of this rule. (2) An owner or operator of more than one hazardous waste management unit subject to rules 3745-256-30 to 3745-256-35 of the Administrative Code may comply with the recordkeeping requirements for these hazardous waste management un... |
Rule 3745-256-50 | Applicability and definitions - air emission standards for equipment leaks.
...except as provided in rule 3745-65-01 of the Administrative Code). (B) Except as provided in paragraph (K) of rule 3745-256-64 of the Administrative Code, rules 3745-256-50 to 3745-256-64 of the Administrative Code apply to equipment that contains or contacts hazardous wastes with organic concentrations of at least ten per cent by weight that are managed in one of the following: (1) A unit that ... |