Rule 4123:1-5-21 | Storage batteries.
...mployees will be instructed that: (1) When charging batteries, acid will be poured into water; water will not be poured into acid; (2) When charging batteries, make certain vent caps are functioning: keep vent caps in place to avoid electrolyte spray, and open covers to dissipate heat; and (3) Smoking and open flames are not permitted. (C) In designated battery charging and changing ar... |
Rule 4123:1-5-22 | Confined spaces.
...or recommended entry procedures): (1) Air sampling shall be performed by qualified, trained personnel prior to and periodically during occupancy to determine that the atmosphere within the confined space contains an adequate concentration of oxygen (minimum of nineteen and one-half per cent to a maximum of twenty-three and one-half per cent), and any known or expected harmful atmospheric cont... |
Rule 4123:1-5-22 | Confined spaces.
...or recommended entry procedures): (1) Air sampling will be performed by qualified, trained personnel prior to and periodically during occupancy to determine that the atmosphere within the confined space contains an adequate concentration of oxygen (minimum of nineteen and one-half per cent to a maximum of twenty-three and one-half per cent), and any known or expected harmful atmospheric conta... |
Rule 4123:1-5-23 | Electrical conductors and equipment.
...trical conductor, the employer shall: (1) Assure that the conductor is deenergized and grounded, or (2) Assure that the conductor is moved, or (3) Assure that the conductor is guarded from accidental contact and an employee is designated to act as signalman to direct the operator in the movement of the equipment, or (4) Assure that an insulated boom or an insulated type guard about the boom or arm of the equipmen... |
Rule 4123:1-5-23 | Electrical conductors and equipment.
...ctrical conductor, the employer will: (1) Assure that the conductor is deenergized and grounded, or (2) Assure that the conductor is moved, or (3) Assure that the conductor is guarded from accidental contact and an employee is designated to act as signalman to direct the operator in the movement of the equipment, or (4) Assure that an insulated boom or an insulated type guard about the boom or arm of the equipmen... |
Rule 4123:1-5-25 | Vehicle-mounted elevating and rotating work platforms.
...stable support for the aerial device. (1) Alternative configuration. (a) If the aerial device is capable of alternative configurations, these configurations, including the rated capacity in each situation, shall be stated on the operating instruction plate(s). Examples of alternative configurations requiring such a description on operating instruction plate(s) are as follows: (i) Without extending outriggers vs. w... |
Rule 4123:1-5-25 | Vehicle-mounted elevating and rotating work platforms.
...stable support for the aerial device. (1) Alternative configuration. (a) If the aerial device is capable of alternative configurations, these configurations, including the rated capacity in each situation, will be stated on the operating instruction plate(s). Examples of alternative configurations needing such a description on operating instruction plate(s) are as follows: (i) Without extending... |
Rule 4123:1-5-26 | Trenches and excavations.
...(A) General specifications. (1) Utility companies and municipally owned utilities will be contacted and advised of proposed work prior to the start of actual excavation. Prior to opening an excavation, effort will be made to determine whether underground installations, i.e., sewer, telephone, water, fuel, electric lines, etc., will be encountered and, if so, where such underground installations are located. (2) An ... |
Rule 4123:1-5-28 | Helicopters.
... |
Rule 4123:1-5-99 | Table of standard materials and dimensions.
... |
Rule 4123:1-7-01 | Scope and definitions.
...s chapter supplement those of Chapter 4123:1-5 of the Administrative Code, and are minimum requirements of an employer for the protection of such employer's employees and no others and apply to the manufacture of castings containing iron, steel, brass, copper, tin, zinc, lead, aluminum, or any of the baser metals, but do not apply to steel making or any processes used in conjunction with steel manufacturing and fabr... |
Rule 4123:1-7-01 | Scope and definitions.
...hapter supplement those of Chapter 4123:1-5 of the Administrative Code, and pertain to the employer for the protection of such employer's employees and no others and apply to the manufacture of castings containing iron, steel, brass, copper, tin, zinc, lead, aluminum, or any of the baser metals, but do not apply to steel making or any processes used in conjunction with steel manufacturing and ... |
Rule 4123:1-9-01 | Scope and definitions.
...uirements supplement those of Chapter 4123:1-5 of the Administrative Code, "Specific Safety Requirements of the Ohio Bureau of Workers' Compensation Relating to All Workshops and Factories," and are minimum requirements of an employer for the protection of such employer's employees and no others and apply to steel making and the processes used in conjunction with steel manufacturing and fabricating but do not apply ... |
Rule 4123:1-9-01 | Scope and definitions.
...hapter supplement those of Chapter 4123:1-5 of the Administrative Code, and pertain to the employer for the protection of such employer's employees and no others and apply to steel making and the processes used in conjunction with steel manufacturing and fabricating but do not apply to the manufacture of foundry type operations. Installations or constructions built or contracted for prior to ... |
Rule 4123:1-11-01 | Scope and definitions.
...ecific requirements supplement Chapter 4123:1-5 of the Administrative Code, "Specific Safety Requirements of the Ohio Bureau of Workers' Compensation Relating to All Workshops and Factories," and are minimum requirements of an employer for the protection of such employer's employees and no others and apply to places of employment wherein laundering or drycleaning processes are performed. Installations or constructio... |
Rule 4123:1-11-01 | Scope and definitions.
...of this chapter supplement Chapter 4123:1-5 of the Administrative Code and pertain to the employer for the protection of such employer's employees and no others and apply to places of employment wherein laundering or drycleaning processes are performed. Installations or constructions built or contracted for prior to the effective date of any specification are deemed to comply with the provisi... |
Rule 4123:1-13-01 | Scope and definitions.
...ements supplement those of Chapter 4123:1-5 of the Administrative Code, "Specific Safety Requirements of the Ohio Bureau of Workers' Compensation Relating to All Workshops and Factories," and are minimum requirements of an employer for the protection of such employer's employees and no others and apply to the rubber and plastic industries where crude, synthetic, or reclaimed rubber or plastics are... |
Rule 4123:1-13-01 | Scope and
definitions.
...ements supplement those of Chapter 4123:1-5 of the Administrative Code and are minimum requirements of an employer for the protection of such employer's employees and no others and apply to the rubber and plastic industries where crude, synthetic, or reclaimed rubber or plastics are processed. Equipment used in the laboratory varies greatly from manufacturing equipment in size, speed, and height ... |
Rule 4123:1-13-02 | Mills.
...or on a platform. (B) Mill controls. (1) Safety trip control. A safety trip control shall be provided in front and in back of each mill to stop the mill when it is tripped. It shall be accessible and shall operate readily on contact. The safety trip control shall be one of the following types or a combination thereof. (a) Pressure-sensitive body bars. Installed at front and back of each mill twenty inches (50.8... |
Rule 4123:1-13-02 | Mills.
...or on a platform. (B) Mill controls. (1) Safety trip control. A safety trip control shall be provided in front and in back of each mill to stop the mill when it is tripped. The safety trip control shall be accessible and operate readily on contact. The safety trip control shall be one of the following types or a combination thereof. (a) Pressure-sensitive body bars. Installed at front and back of each mill twen... |
Rule 4123:1-17-01 | Scope and definitions.
...afety requirements supplement Chapter 4123:1-5 of the Administrative Code, "Specific Safety Requirements of the Ohio Bureau of Workers' Compensation Relating to all Workshops and Factories," but, to the extent of inconsistency between these and any provision of Chapter 4123:1-5 of the Administrative Code, these shall apply. These requirements are minimum requirements of an employer for the protection of such employ... |
Rule 4123:1-17-01 | Scope and definitions.
...hapter supplement those of Chapter 4123:1-5 of the Administrative Code, but to the extent of inconsistency between these and any provision of Chapter 4123:1-5 of the Administrative Code, these provisions shall apply. These provisions are minimum requirements of an employer for the protection of such employer's employees and no others. These provisions constitute protective standards for all em... |
Rule 4123:1-17-02 | Ladders.
...requirements of paragraph (C) of rule 4123:1-5-03 of the Administrative Code in addition to the following: (A) Metal ladders shall not be provided for use where exposed electrical contacts are present. (B) Metal ladders shall not be provided when damaging chemicals are to be used, unless the ladder used has been appropriately treated to protect it from such chemicals. (C) The use of ladders with hooks attached, t... |
Rule 4123:1-17-02 | Ladders.
...hall comply with paragraph (C) of rule 4123:1-5-03 of the Administrative Code in addition to the following: (A) Metal ladders shall not be provided for use where exposed electrical contacts are present. (B) Metal ladders shall not be provided when damaging chemicals are to be used unless the ladder used has been appropriately treated to protect it from such chemicals. (C) The use of ladders with hook... |
Rule 4123:1-17-03 | Swinging scaffolds.
...nging scaffold in compliance with rule 4123:1-17-06 of the Administrative Code. (J) Employees shall not be required to use a bridge, or to move directly, between one swinging scaffold and another. (K) Each swinging scaffold shall be securely fastened to the building or structure at each work location to prevent it from swaying. Window cleaners' anchors shall not be used for this purpose. Tie-in anchors designed fo... |