Rule 4901:1-10-26 | Annual system improvement plan report.

... The annual report shall include: (1) A plan for investment in and improvements to the electric utility's or transmission owner's transmission and distribution facilities/equipment that will ensure high quality, safe, and reliable delivery of energy to customers and will provide the delivery reliability needed for fair and open competition. Each plan shall also contain the estimated cost of i...

Rule 4901:1-10-26 | Annual system improvement plan report.

... The annual report shall include: (1) A plan for investment in and improvements to the electric utility's or transmission owner's transmission and distribution facilities/equipment. Each plan shall: (a) Cover all of the electric utility's service territory, and shall describe the relevant characteristics of the service territory including the following: (i) Miles of overhead distribut...

Rule 4901:1-10-27 | Inspection, maintenance, repair, and replacement of transmission and distribution facilities (circuits and equipment).

...ce pursuant to paragraph (F) of rule 4901:1-10-02 of the Administrative Code, does not apply to this rule. (B) Distribution system performance assessment. For electric distribution circuits, the electric utility shall comply with rule 4901:1-10-11 of the Administrative Code. (C) Transmission system performance assessment. Every five years each electric utility and transmission owner shall file with the commission a...

Rule 4901:1-10-27 | Inspection, maintenance, repair, and replacement of transmission and distribution facilities (circuits and equipment).

... pursuant to paragraph (F) of rule 4901:1-10-02 of the Administrative Code, does not apply to this rule. (B) Distribution system performance assessment. For electric distribution circuits, the electric utility shall comply with rule 4901:1-10-11 of the Administrative Code. (C) Transmission system performance assessment. Every five years each electric utility and transmission owner shall file w...

Rule 4901:1-10-27 | Inspection, maintenance, repair, and replacement of transmission and distribution facilities (circuits and equipment).

... pursuant to paragraph (F) of rule 4901:1-10-02 of the Administrative Code, does not apply to this rule. (B) Transmission system performance assessment. Every five years each electric utility and transmission owner shall file with the commission a report setting forth its methodology used to assess the reliability of its transmission circuits. That methodology shall be subject to review and acc...

Rule 4901:1-10-28 | Net metering.

... following definitions shall apply: (1) "Advanced meter" means any electric meter that meets the pertinent engineering standards using digital technology and is capable of providing two-way communications with the electric utility to provide usage and/or other technical data. (2) "CRES provider" shall mean any provider of competitive retail electric service. (3) "Customer-generator" shall...

Rule 4901:1-10-28 | Net metering.

... the following definitions apply: (1) "Advanced meter" means any electric meter that meets the pertinent engineering standards using digital technology and is capable of providing two-way communications with the electric utility to provide usage and/or other technical data. (2) "CRES provider" means any provider of competitive retail electric service. (3) "Customer-generator" has the me...

Rule 4901:1-10-30 | Failures to comply with the rules or commission orders.

...ing but not limited to the following: (1) Forfeiture to the state of not more than ten thousand dollars for each such failure, with each day's continuance of the violation being a separate offense. (2) Corrective action to effectuate compliance. (3) Restitution or damages to the customer/consumer. (B) Enforcement of any rule in this chapter or commission order, direction or requirement promulgated thereunder, wil...

Rule 4901:1-10-31 | Environmental disclosure.

...ion of environmental disclosure data. (1) Contents of environmental disclosure data. (a) Approximate generation resource mix. Each electric utility shall specifically identify each of the following generation sources used in the generation of the power that is made available under its standard offer: biomass power, coal-fired power, hydro power, natural gas-fired power, nuclear power, oil-fired power, other source...

Rule 4901:1-10-31 | Environmental disclosure.

...of environmental disclosure data. (1) Contents of environmental disclosure data. (a) Approximate generation resource mix. Each electric utility shall specifically identify each of the following generation sources used in the generation of the power that is made available under its standard offer: biomass power, coal-fired power, hydro power, natural gas-fired power, nuclear power, oil-fired...

Rule 4901:1-10-32 | Cooperation with certified governmental aggregators.

...ment list, the following information: (1) An updated list of names, account numbers, service addresses, billing addresses, rate codes, percentage of income payment plan codes, load data, and other related customer information, consistent with the information that is provided to other electric services companies, must be available in spreadsheet, word processing, or an electronic non-image-based format, with formulas...

Rule 4901:1-10-32 | Cooperation with certified governmental aggregators.

... list, the following information: (1) An updated list of names, account numbers, service addresses, billing addresses, rate codes, percentage of income payment plan codes, load data, and other related customer information, consistent with the information that is provided to other electric services companies, must be available in spreadsheet, word processing, or an electronic non-image-based f...

Rule 4901:1-10-33 | Consolidated billing requirements.

...e at least the following information: (1) The customer's name, billing address, and service address. (2) The electric utility's twenty-four hour, local and toll-free telephone numbers for reporting service emergencies. (3) The dates of the service period covered by the bill. (4) Current electric charges, separated from gas charges, if these charges appear on the same bill, but only to the extent that the biller p...

Rule 4901:1-10-33 | Consolidated billing requirements.

... least the following information: (1) The customer's name, billing address, and service address. (2) The electric utility's twenty-four hour, local and toll-free telephone numbers for reporting service emergencies. (3) The dates of the service period covered by the bill. (4) Current electric charges, separated from gas charges, if these charges appear on the same bill, but only to the ...

Rule 4901:1-10-33 | Consolidated billing requirements.

... at least the following information: (1) The customer's name, billing address, and service address. (2) The electric utility's twenty-four hour, local and toll-free telephone numbers for reporting service emergencies. (3) The dates of the service period covered by the bill. (4) Current electric charges, separated from gas charges, if these charges appear on the same bill, but only to the ...

Rule 4901:1-10-34 | Compliance with PURPA.

...he following definitions shall apply: (1) "Day-ahead energy market" means the day-ahead hourly forward market in which participants offer to sell and bid to buy energy. (2) "Locational marginal price" means the hourly integrated market clearing price for energy at the location the energy is delivered or received. (3) "PURPA" means the Public Utility Regulatory Policies Act of 1978, as amended by the Energy Policy...

Rule 4901:1-10-34 | Compliance with PURPA.

... the following definitions apply: (1) "Day-ahead energy market" means the day-ahead hourly forward market in which participants offer to sell and bid to buy energy. (2) "Locational marginal price" means the hourly integrated market clearing price for energy at the location the energy is delivered or received. (3) "PURPA" means the Public Utility Regulatory Policies Act of 1978, as amended ...

Rule 4901:1-10-35 | Disclosures of Renewable Energy Resource, Energy Efficiency, and Peak Demand Reduction Compliance Costs.

...he following definitions shall apply: (1) "Energy efficiency" has the meaning set forth in paragraph (N) of rule 4901:1-39-01 of the Administrative Code. (2) "Renewable energy resource" has the meaning set forth in division (A)(37) of section 4928.01 of the Revised Code. (B) Each electric distribution utility (EDU) shall list on all customer bills sent by the EDU, the individual customer cost of compliance for par...

Rule 4901:1-10-35 | Disclosures of renewable energy resource, energy efficiency, and peak demand reduction compliance costs.

... the following definitions apply: (1) "Energy efficiency" has the meaning set forth in paragraph (N) of rule 4901:1-39-01 of the Administrative Code. (2) "Renewable energy resource" has the meaning set forth in division (A)(37) of section 4928.01 of the Revised Code. (B) Each electric distribution utility (EDU) shall list on all customer bills sent by the EDU, the individual customer co...

Rule 4901:1-12-01 | Definitions.

..., without adherence to section 4909.18 or 4909.19 of the Revised Code, recover on a uniform basis per unit of sales Ohio coal research and development costs, determined to be reasonable by the commission. (D) "Ohio coal research and development costs" means all reasonable costs associated with a facility or project undertaken by a public utility, for which a recommendation to allow the recove...

Rule 4901:1-12-01 | Definitions.

..., without adherence to section 4909.18 or 4909.19 of the Revised Code, recover on a uniform basis per unit of sales Ohio coal research and development costs, determined to be reasonable by the commission. (D) "Ohio coal research and development costs" has the same meaning as in section 4905.01 of the Revised Code. (E) "Ohio coal research and development project" means any coal research and d...

Rule 4901:1-12-04 | Applicability.

...provided under paragraph (A) of rule 4901:1-12-06 of the Administrative Code. (B) The provisions of this chapter shall not apply to municipal ordinance rates established under section 743.26 or 4909.34 of the Revised Code or Section 4 of Article XVIII, Ohio Constitution, except in instances where a municipal ordinance adopts, by reference or otherwise, rates established by the commission. (C) Th...

Rule 4901:1-12-04 | Applicability.

...provided under paragraph (A) of rule 4901:1-12-06 of the Administrative Code. (B) The commission may, upon an application or a motion filed by a party, waive any requirement of this chapter, other than a requirement mandated by statute, for good cause shown.

Rule 4901:1-12-05 | Monthly reports.

...omponent as specified in paragraphs (A)(1) and (A)(2) of rule 4901:1-12-06 of the Administrative Code. (B) Semiannual reports. Each gas or natural gas company subject to the provisions of this chapter shall submit semiannual Ohio coal research and development reports with every sixth monthly report. The semiannual report shall include the data required by the Ohio coal research and development cost form to calculat...

Rule 4901:1-12-05 | Semiannual reports.

...graphs (B), (C), and (D) of rule 4901:1-12-06 of the Administrative Code.