Rule 901:5-2-03 | Design requirements - bulk liquid fertilizer storage.

...(A) Permanent storage vessels: (1) Shall be constructed entirely of materials recommended by the manufacturer or specified in applicable standards for use with the type of liquid to be stored in the vessel; (2) Shall be designed according to generally accepted engineering standards and practices for liquid storage vessels and shall take into consideration the full hydrostatic head pressu...

Rule 901:5-2-04 | Inspection, maintenance alteration, repair and reconstruction.

...more permanent storage vessels shall: (1) Once each week: (a) Check all liquid level gauging equipment to ensure it is functioning properly; (b) Check roof drains for obstructions; (c) Check vents and pressure-relief devices for obstructions; (d) Check electrical grounding lines and connections for integrity; (e) Visually inspect the dike of the secondary containment facility for erosion, cracks and deteriorati...

Rule 901:5-2-04 | Inspection, maintenance alteration, repair and reconstruction.

... permanent storage vessels shall: (1) Once each week: (a) Check all liquid level gauging equipment to ensure it is functioning properly; (b) Check roof drains for obstructions; (c) Check vents and pressure-relief devices for obstructions; (d) Check electrical grounding lines and connections for integrity; (e) Visually inspect the dike of the secondary containment facility for erosion, cr...

Rule 901:5-2-07 | Required records.

...the storage facility is administered: (1) A record of all discharges at the storage facility, including the date and time of discharge, the type of liquid bulk fertilizer discharged, the volume of the discharge, the cause of the discharge, any action taken to control or recover the discharge, and the method of disposal of any recovered discharge. The discharge record shall be completed on the day the discharge is di...

Rule 901:5-2-09 | Existing permanent storage vessels erected on site.

...ed on site shall, no later than January 1, 2003, have a baseline inspection done on each vessel by an authorized inspector to determine if the vessels comply with the API 650 standard. (1) The baseline inspection report for each exsisting permanent storage vessel erected on site that complies with the API 650 standard shall be kept on the property where the vessel is located. (2) The baseline inspecton report for e...

Rule 901:5-2-10 | New permanent storage vessels erected on site.

...(A) After January 1, 2002, no person shall either erect on site or cause to be erected on site a new permanent storage vessel unless; (1) It is built to: (a) The API 650 standard; or (b) Exceed the API 650 standard. If the vessel is to be built to exceed the API 650 standard, plans and specifications for the vessel shall be submitted to the director prior to installation of the vessel. The plans and specification...

Rule 901:5-2-10 | New permanent storage vessels erected on site.

... permanent storage vessel unless: (1) It is built to: (a) The API 650 standard; or (b) Exceed the API 650 standard. If the vessel is to be built to exceed the API 650 standard, plans and specifications for the vessel shall be submitted to the director prior to installation of the vessel. The plans and specifications submitted under this section shall include documentation prepared by a prof...

Rule 901:5-2-11 | Underground piping systems for loading and unloading liquid fertilizer.

...rds required by paragraph (D) of rule 901:5-2-07 of the Administrative Code. If the underground piping system is to be used and designed as pressure piping without secondary containment, a professional engineer must certify, by letter to the department, that the underground piping system as designed meets the following requirements: (A) All underground piping systems in place prior to the effective date of this rul...

Rule 901:5-2-11 | Underground piping systems for loading and unloading liquid fertilizer.

...s required by paragraph (D) of rule 901:5-2-07 of the Administrative Code. If the underground piping system is to be used and designed as pressure piping without secondary containment, a professional engineer must certify, by letter to the department, that the underground piping system as designed meets the following requirements: (A) The department shall be notified by the owner prior to: (1) Beginnin...

Rule 901:5-3-12 | Systems utilizing stationary, pier-mounted or skid-mounted storage.

... filling and discharge connections: (1) Each filling connection shall be provided with combination back-pressure check valve and excess flow valve; one double or two single back-pressure check valves; or a positive shut-off valve in conjunction with either an internal back-pressure check valve or an internal excess flow valve; (2) All vapor and liquid connections, except safety-relief valves a...

Rule 901:5-3-12 | Systems utilizing stationary, pier-mounted or skid-mounted storage.

...es, filling and discharge connections (1) Each filling connection shall be provided with combination back-pressure check valve and excess flow valve; one double or two single back-pressure check valves; or a positive shut-off valve in conjunction with either an internal back-pressure check valve or an internal excess flow valve. (2) All vapor and liquid connections, except safety-relief valves and those specificall...

Rule 901:5-4-03 | Education requirements.

...cates the applicant on the following: (1) The proper times to apply fertilizer, including time of day and time of season; (2) The proper place to apply fertilizer; (3) The form of fertilizer that should be applied; (4) The proper amount of fertilizer to be applied; (5) The storage and handling of fertilizer; and (6) The proper fertilizer application techniques. (B) Each applicant for an initial fertilizer cer...

Rule 901:5-7-01 | Definitions and terms.

...rican feed control officials (AAFCO): (1) The official definitions of the feed ingredients, the official feed terms, and the process and procedures as contained in the 2013 edition of the "Official Publication"; and (2) The May 1, 2000, AAFCO feed inspectors manual. (B) Under authority of division (C) of section 923.41 of the Revised Code the following commodities when not mixed with other materials, are exempt fr...

Rule 901:5-11-01 | Definitions.

...ngicide, and Rodenticide Act," 7 U.S.C. 136 et seq., (2014). (I) "Non-mobile liquid bulk pesticide storage container" means a liquid bulk pesticide container which is not designed by its manufacturer to be readily moved when full of product. (J) "Pesticide solicitor" means a pesticide business whose sole pesticide business activity is seeking to sell pesticide applications. (K) "Public lawn...

Rule 901:5-11-01 | Definitions.

...tribution to another person. (D) "21 C.F.R." means title twenty-one of the Code of Federal Regulations (2022). (E) "40 C.F.R." means title forty of the Code of Federal Regulations (2023). (F) "Commercial lawn" means any cultivated turf, public or private, other than residential lawns, cultivated for aesthetic purposes. (G) "Custom mixes or blends" means any pesticide which is combined with...

Rule 901:5-11-09 | Notification requirements for lawn pesticide applicators.

...ion of a commercial applicator shall: (1) Apply any lawn pesticides to residential lawns in any municipal corporation or subdivided area of a township unless the applicator has done all of the following: (a) They provide the following information in writing to the person on whose property the chemical is being applied. This information shall be provided prior to or at the time of application: (i) The brand or comm...

Rule 901:5-11-10 | Recordkeeping.

...(A) Commercial applicators: (1) Applying pesticides under the pesticide use categories defined in paragraphs (N)(7) and (N)(10) of rule 901:5-11-01 of the Administrative Code, or to structures and their contents shall record, in English, on the date of application the following information for each application made by the commercial applicator or trained servicepersons working under the commercia...

Rule 901:5-11-10 | Recordkeeping.

...(A) Commercial applicators: (1) Applying pesticides under the pesticide use categories defined in paragraphs (P)(7) and (P)(10) of rule 901:5-11-01 of the Administrative Code, or to structures and their contents shall record, in English, on the date of application the following information for each application made by the commercial applicator or trained servicepersons working under the commercia...

Rule 901:5-11-11 | Storage, handling, disposal and distribution of pesticides, custom mixes and blends.

...(A) Storage: (1) Pesticides shall not be stored: (a) In a manner that could result in contamination of animal feeds or commercial fertilizers; (b) Above or against feed components, animal foods, foodstuffs, medications, or children's toys; or (c) Loaded into aerial application equipment within one hundred yards of an airline passenger terminal. (2) For display purposes: (a) Pesticides shall not be shelved abov...

Rule 901:5-11-11 | Storage, handling, disposal and distribution of pesticides, custom mixes and blends.

...(A) Storage: (1) Pesticides shall not be stored: (a) In a manner that could result in contamination of animal feeds or commercial fertilizers; (b) Above or against feed components, animal foods, foodstuffs, medications, or children's toys; or (c) Loaded into aerial application equipment within one hundred yards of an airline passenger terminal. (2) For display purposes: (a) Pesticides shall not...

Rule 901:5-11-13 | Recordkeeping for wood-destroying insect diagnostic inspections for real estate transactions.

...formation in section one of the form: (1) The name, address and telephone number of the pesticide business conducting the inspection; (2) The license number of the pesticide business or registered location conducting the inspection; (3) The date of the inspection; (4) The physical address of the property inspected; (5) The name, license number and original signature of the commercial ...

Rule 901:5-11-15 | Pesticide use in schools.

...is rule shall apply to the following: (1) School classroom buildings established under Chapter 3311. of the Revised Code; (2) Education service centers and community schools established under Chapter 3314. of the Revised Code; (3) STEM schools established under Chapter 3326. of the Revised Code; and (4) Non-public schools chartered by the board of education pursuant to section 3301.16 of the Revised Code. (B) Pe...

Rule 901:5-11-99 | Civil penalties.

...sessed for each violation of sections 921.01 to 921.29 of the Revised Code, any rule adopted, and any order issued under authority of these sections. The amount of the penalty shall be based on the following criteria: (1) The cost to the department of agriculture to investigate the violation. Calculation of the cost shall include: (a) The average salary of all state employees directly involved in pesticide use inve...

Rule 901:5-27-07 | Seed labeler permit application.

... if it contains all of the following: (1) The name and address of the applicant; (2) The telephone and facsimile number of the applicant; (3) The email address and website address of the applicant; (4) The county in which the applicant is located; (5) The kind of seed that the labeler sells; (6) Each Ohio location where seed to be labeled by the applicant may be sampled; (7) The original signature of the appli...

Rule 901:5-27-07 | Seed labeler permit application.