Rule 3745-18-15 | Butler county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Butler county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 2.4 pounds of sulfur dioxide per MM Btu actual heat input. (B) [Reserved.] (C) The "Cleveland-Cliffs Steel Corporation " (OEPA premise number 1409010006) or any subsequent owner or ...

Rule 3745-18-24 | Cuyahoga county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit greater than three hundred fifty MM Btu actual heat input in Cuyahoga county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 1.2 pounds of sulfur dioxide per MM Btu actual heat input. (B) No owner or operator of any coal-fired steam generating unit between ten MM Btu ...

Rule 3745-18-24 | Cuyahoga county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit greater than three hundred fifty MM Btu actual heat input in Cuyahoga county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 1.2 pounds of sulfur dioxide per MM Btu actual heat input. (B) No owner or operator of any coal-fired steam generating ...

Rule 3745-18-26 | Defiance county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Defiance county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 2.6 pounds of sulfur dioxide per MM Btu actual heat input. (B) [Reserved.] (C) The "Richland Substation Peaker Facility" (OEPA premise number 0320010006) or any subsequent owner or operator of the "Ri...

Rule 3745-18-26 | Defiance county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Defiance county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 2.6 pounds of sulfur dioxide per MM Btu actual heat input. (B) [Reserved.] (C) The "Richland Substation Peaker Facility" (OEPA premise number 0320010006) or any subsequent owner or...

Rule 3745-18-28 | Erie county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Erie county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 2.6 pounds of sulfur dioxide per MM Btu actual heat input. (B) [Reserved.] (C) [Reserved.] (D) [Reserved.] (E) [Reserved.] (F) The "Mississippi Lime Company - Huron Plant" (OEPA premise number 03220100...

Rule 3745-18-28 | Erie county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Erie county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 2.6 pounds of sulfur dioxide per MM Btu actual heat input. (B) [Reserved.] (C) [Reserved.] (D) [Reserved.] (E) [Reserved.] (F) The "Carmeuse Lime Inc. - Huron Plant" (OEPA premise n...

Rule 3745-18-33 | Gallia county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Gallia county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 4.5 pounds of sulfur dioxide per MM Btu actual heat input. (B) The "Ohio Valley Electric Corporation, Kyger Creek Station" (OEPA premise number 0627000003) or any subsequent owner...

Rule 3745-18-37 | Hamilton county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Hamilton county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 2.0 pounds of sulfur dioxide per MM Btu actual heat input. (B) The "INEOS ABS Corporation" (OEPA permits number 1431010054) or any subsequent owner or operator of the "INEOS ABS Corporation, 356 Three ...

Rule 3745-18-37 | Hamilton county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Hamilton county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 2.0 pounds of sulfur dioxide per MM Btu actual heat input. (B) The "INEOS ABS (USA) Corporation" (OEPA permits number 1431010054) or any subsequent owner or operator of the "INE...

Rule 3745-18-47 | Jefferson county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Jefferson county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 1.8 pounds of sulfur dioxide per MM Btu actual heat input. (B) No owner or operator of any oil-fired steam generating unit in Jefferson county, unless otherwise specified in this ...

Rule 3745-18-47 | Jefferson county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Jefferson county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 1.8 pounds of sulfur dioxide per MM Btu actual heat input. (B) No owner or operator of any oil-fired steam generating unit in Jefferson county, unless otherwise specified in this ...

Rule 3745-18-49 | Lake county emission limits.

...[Comment: For dates and availability of non-regulatory government publications, publications of recognized organizations and associations, federal rules, and federal statutory provisions referenced in this rule, see paragraph (C) of rule 3745-18-01 of the Administrative Code titled "referenced materials."] (A) No owner or operator of any coal-fired steam generating unit in Lake county, unless otherwise specified in ...

Rule 3745-18-49 | Lake county emission limits.

...[Comment: For dates and availability of non-regulatory government publications, publications of recognized organizations and associations, federal rules, and federal statutory provisions referenced in this rule, see paragraph (C) of rule 3745-18-01 of the Administrative Code titled "referenced materials."] (A) No owner or operator of any coal-fired steam generating unit in Lake county, unless otherwise s...

Rule 3745-18-53 | Lorain county emission limits.

...(A) Except as otherwise specified in this rule, no owner or operator of any fossil-fuel fired steam generating unit in Lorain county shall cause or permit the emission of sulfur dioxide to exceed the following limits from any stack: (1) The emission limit for sources between 10.0 and 100.0 MM Btu per hour total rated capacity shall be calculated from the following equation: EL = 21.176 Qm -0.5477 where Qm is the ...

Rule 3745-18-53 | Lorain county emission limits.

...(A) Except as otherwise specified in this rule, no owner or operator of any fossil-fuel fired steam generating unit in Lorain county shall cause or permit the emission of sulfur dioxide to exceed the following limits from any stack: (1) The emission limit for sources between 10.0 and 100.0 MM Btu per hour total rated capacity shall be calculated from the following equation: EL = 21.176 Qm -0.547...

Rule 3745-18-54 | Lucas county emission limits.

...[Comment: For dates of non-regulatory government publications, publications of recognized organizations and associations, federal rules, and federal statutory provisions referenced in this rule, see paragraph (C) of rule 3745-18-01 of the Administrative Code titled "Referenced materials."] (A) No owner or operator of any coal-fired steam generating unit in Lucas county, unless otherwise specified in this rule, shall...

Rule 3745-18-54 | Lucas county emission limits.

...[Comment: For dates of non-regulatory government publications, publications of recognized organizations and associations, federal rules, and federal statutory provisions referenced in this rule, see paragraph (C) of rule 3745-18-01 of the Administrative Code titled "Referenced materials."] (A) No owner or operator of any coal-fired steam generating unit in Lucas county, unless otherwise specified in ...

Rule 3745-18-63 | Montgomery county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Montgomery county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 1.5 pounds of sulfur dioxide per MM Btu actual heat input. (B) [Reserved.] (C) [Reserved.] (D) [Reserved.] (E) [Reserved.] (F) [Reserved.] (G) [Reserved.] (H) [Reserved.] (I) The "DP&L Tait Ge...

Rule 3745-18-63 | Montgomery county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Montgomery county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 1.5 pounds of sulfur dioxide per MM Btu actual heat input. (B) [Reserved.] (C) [Reserved.] (D) [Reserved.] (E) [Reserved.] (F) [Reserved.] (G) [Reserved.] (H) [Reserved.] (I) T...

Rule 3745-18-68 | Ottawa county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Ottawa county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 5.9 pounds of sulfur dioxide per MM Btu actual heat input. (B) [Reserved.] (C) The "Graymont Dolime (OH), Inc." (OEPA premise number 0362000079) or any subsequent owner or operator of the "Graymont Doli...

Rule 3745-18-68 | Ottawa county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Ottawa county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 5.9 pounds of sulfur dioxide per MM Btu actual heat input. (B) [Reserved.] (C) The "Graymont Dolime (OH), Inc." (OEPA premise number 0362000079) or any subsequent owner or operator ...

Rule 3745-18-77 | Ross county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Ross county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 3.6 pounds of sulfur dioxide per MM Btu actual heat input. (B) The "P.H. Glatfelter Company - Chillicothe Facility" (OEPA premise number 0671010028) or any subsequent owner or operator of the "P.H. Glatfel...

Rule 3745-18-77 | Ross county emission limits.

...(A) No owner or operator of any coal-fired steam generating unit in Ross county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any source to exceed a maximum of 3.6 pounds of sulfur dioxide per MM Btu actual heat input. (B) The "Pixelle Specialty Solutions LLC" (OEPA premise number 0671010028) or any subsequent owner or operator of the "Pix...

Rule 3745-18-82 | Stark county emission limits.

...(A) No owner or operator of a facility in Stark county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any stack in excess of the following rates: (1) For fossil fuel-fired steam generating units between ten and sixty MM Btu per hour total rated heat input capacity, the emission rate in pounds of sulfur dioxide per MM Btu actual heat input shall be calculated by th...