Rules
Rule
Rule 4101:3-3-01 | General regulations.

...

Rule 4101:3-4-01 | Fixtures, faucets and fixture fittings.

...

Rule 4101:3-5-01 | Water heaters.

...

Rule 4101:3-6-01 | Water supply and distribution.

...

Rule 4101:3-7-01 | Sanitary drainage.

...

Rule 4101:3-8-01 | Indirect/special waste.

...

Rule 4101:3-9-01 | Vents.

...

Rule 4101:3-10-01 | Traps, interceptors and separators.

...

Rule 4101:3-11-01 | Storm drainage.

...

Rule 4101:4-4-03 | Safety devices and controls.

... hour for each kilowatt input. (E) The discharge of safety valves and other outlets shall be installed so as not to endanger any person. (F) Replacement of existing safety devices and controls shall comply with the requirements for new safety devices and controls as prescribed in the applicable section of the "ASME Boiler and Pressure Vessel Code" as referenced in rule 4101:4-3-01 of the Administrative Code. (G) W...

Rule 4101:4-4-04 | Steam boiler blowoff systems.

...(A) The blowoff from boilers may be discharged directly to any place such as a lake, swamp, stream, sump, or open pit provided there is no hazard to life or property. Where a safe place of discharge is not available, a blowoff tank shall be used. The tank shall be designed to separate the flash steam from the water and shall be flashed to a lower pressure system or vented to the atmosphere. The vent shall be large en...

Rule 4101:6-1-24 | Definitions and methods of sterilization or sanitization processes required.

... with sealed joints to the outside that discharge above the roof of the building and shall not be located nearer than one hundred feet of any residence. Exhaust and air inlet valves of positive locking type shall be provided. Space for free circulation of gas between and around articles of bedding undergoing sterilization shall be at least one inch. (B) Sanitization method includes the following:...

Rule 4101:8-2-01 | Definitions.

...

Rule 4101:8-8-01 | Roof-ceiling construction.

...

Rule 4101:8-9-01 | Roof assemblies.

...

Rule 4101:8-14-01 | Heating and cooling equipment and appliances.

...

Rule 4101:8-15-01 | Exhaust systems.

...

Rule 4101:8-16-01 | Duct systems.

...

Rule 4101:8-18-01 | Chimneys and vents.

...

Rule 4101:8-20-01 | Boilers and water heaters.

...

Rule 4101:8-22-01 | Special piping and storage systems.

...

Rule 4101:8-23-01 | Solar thermal energy systems.

...

Rule 4101:8-24-01 | Fuel gas.

...

Rule 4101:8-29-01 | Water supply and distribution.

...

Rule 4101:9-2-19 | Railroad occupations.

...at regular stations for the receipt and discharge of freight and passengers. The term "railroad" includes any tracks laid on, along, or under the streets of a municipality even though used primarily for the accommodation of passengers going from one point to another in such municipality or to and from the suburbs. (B) The term "occupation in or about a railroad" includes, but is not limited to, brakemen, conductors,...